51
Part name
Figure
Check method and criterion
: INNER PROTECTOR
P
Outdoor fan moter(MF)
Horizontal vane
motor(MV1)
Vertical vane
motor(MV2)
<MS-30RV only>
LEV(Expansion valve)
<MS-30RV only>
Measure the resistance between the terminals with a tester.
(Part temperature –10˚C ~ 40˚C)
Normal
BRN-other one
282 ~ 306
"
Abnormal
Open or short-circuit
Measure the resistance between the terminal with a tester.
(Part temperature10
°
C ~ 30
°
C)
Color of lead wire
WHT – RED
RED – ORN
YLW – BRN
BRN – BLU
Abnormal
Open or
short-circuit
Normal
30.3 ~ 37.0
"
Measure the resistance with a tester.
(Part temperature : –10˚C ~ 40˚C)
Color of lead wire
WHT – BLK
BLK – YLW
YLW – RED
Abnormal
Open or
short circuit
Normal
MS-30RV
55.4 ~ 67.7
"
49.3 ~ 60.3
"
22.9 ~ 28.0
"
Color of lead wire
WHT – BLK
BLK – RED
BLK – YLW
Abnormal
Open or
short circuit
Normal
MS-18RV
102 ~ 126
"
97 ~ 120
"
MS-24RV
71 ~ 88
"
90 ~ 111
"
81 ~ 100
"
MAIN
AUX.
BLK
RED
WHT
ORN
P
MAIN1
AUX.
BLK
YLW
RED
WHT
ORN
P
MAIN2
Vane motor(MV)
<MS-18/24RV only>
Normal
RED-other one
358 ~ 388
"
Abnormal
Open or short-circuit
Measure the resistance between the terminals with a tester.
(Part temperature10
°
C ~ 30
°
C)
YLW
GRN
ORN
BRN
RED
ROTOR
RED ORN WHT
YLW
BLK
MAIN
AUX.1 AUX.2
P
MS-18RV
MS-30RV
MS-24RV
ORN
BLU
YLW
RED
PNK
ROTOR
LEV
WHT
6
RED
1
ORN
4
YL
W
5
BRN
2
BLU
3
OB271--2.qxp 2/7/01 9:04 AM Page 51