2. Trouble criterion of main parts
MS-18RV -
MU-18RV -
MS-24RV -
MU-24RV -
MS-30RV -
MU-30RV -
E1
E1
E1
E1
E1
E1
Part name
Figure
Check method and criterion
Measure the resistance between the terminals with a tester.
(Part temperature –10˚C ~ 40˚C)
Compressor(MC)
Indoor fan motor(MF)
Measure the resistance with a tester.
(Part temperature –10˚C ~ 40˚C)
Measure the resistance with a tester.
(Part temperature 10˚C ~ 30˚C)
Normal
8 k
"
~ 20 k
"
Abnormal
Open or short-circuit
: INNER PROTECTOR
P
Room temperature
thermistor(RT11)
Indoor coil thermistor
(RT12(main), RT13(sub))
Discharge temperature
thermistor(RT62)
<MS-30RV only>
Ambient temperature
thermistor(RT63)
<MS-30RV only>
Measure the resistance with a tester.
Before measurement, hold the thermistor with your hands to warm it up.
(Part temperature 0˚C ~ 40˚C)
Normal
120 k
"
~ 800 k
"
Abnormal
Open or short-circuit
Normal
5 k
"
~ 60 k
"
Abnormal
Open or short-circuit
Motor part
Sensor part
Measure the resistance between the terminals with a tester.
(Part temperature 10˚C ~ 30˚C)
Color of lead wire
BRN – YLW
YLW – GRY
Abnormal
Remain 0V or 5V
Normal
4.5 ~ 5.5V
Measure the voltage power ON.
(When fan revolved one time)
0V
➔
5V
➔
0V
(Approx.)
Abnormal
Open or
short-circuit
Normal
Color of
lead wire
WHT – BLK
BLK – RED
MS-18/24RV
176 ~ 192
"
240 ~ 261
"
MS-30RV
133 ~ 144
"
153 ~ 165
"
MAIN
AUX.
FUSE
BLK
RED
WHT
GR
Y
YL
W
BRN
MS-18/24RV
MS-30RV
Abnormal
Open or
short-circuit
Normal
Terminal
C – R
C – S
MS-18RV
0.95 ~ 1.17
"
1.92 ~ 2.36
"
MS-24RV
0.84 ~ 1.04
"
1.82 ~ 2.24
"
MS-30RV
0.58 ~ 0.71
"
1.39 ~ 1.70
"
BLK
RED
WHT
GR
Y
YL
W
BRN
P
R
C
S
RED
BLK
WHT
MAIN
AUX.
MAIN
AUX.
P
OB271--2.qxp 2/7/01 9:04 AM Page 50