background image

TIL INSTALLATØREN

FÖR INSTALLATÖREN

PARA O INSTALADOR

ΓΙΑ

 

ΑΥΤΟΝ

 

ΠΟΥ

 

ΚΑΝΕΙ

 

ΤΗΝ

 

ΕΓΚΑΤΑΣΤΑΣΗ

PER L’INSTALLATORE

PARA EL INSTALADOR

VOOR DE INSTALLATEUR

POUR L’INSTALLATEUR

FÜR INSTALLATEURE

FOR INSTALLER

Air-Conditioner

SUZ-SA71VA2, SA100VA

INSTALLATION MANUAL

For safe and correct use, read this manual and the indoor unit installation manual thoroughly before installing 
the air-conditioner unit.

INSTALLATIONSHANDBUCH

Aus Sicherheitsgründen und zur richtigen Verwendung vor der Installation die vorliegende Bedienungsanleitung 
und die Installationsanleitung der Innenanlage gründlich durchlesen die Klimaanlage.

MANUEL D’INSTALLATION

Avant d’installer le climatiseur, lire attentivement ce manuel, ainsi que le manuel d’installation de l’appareil 
intérieur pour une utilisation sûre et correcte.

INSTALLATIEHANDLEIDING

Lees deze handleiding en de installatiehandleiding van het binnenapparaat zorgvuldig door voordat u met het 
installeren van de airconditioner begint.

MANUAL DE INSTALACIÓN

Para un uso correcto y seguro, lea detalladamente este manual y el manual de instalación de la unidad interior 
antes de instalar la unidad de aire acondicionado.

MANUALE DI INSTALLAZIONE

Per un uso sicuro e corretto, leggere attentamente il presente manuale ed il manuale d’installazione dell’unità 
interna prima di installare il condizionatore d’aria.

E

ΓΧ

EIPI

Δ

IO O

Δ

H

Γ

I

Ω

N E

Γ

KATA

Σ

TA

Σ

H

Σ

Για

 

σωστή

 

και

 

ασφαλή

 

χρήση

διαβάστε

 

προσεκτικά

 

αυτό

 

το

 

εγχειρίδιο

 

καθώς

 

και

 

το

 

εγχειρίδιο

 

εγκατάστασης

 

της

 

εσωτερικής

 

μονάδας

προτού

 

εγκαταστήσετε

 

τη

 

μονάδα

 

του

 

κλιματιστικού

.

MANUAL DE INSTALAÇÃO

Para uma utilização segura e correcta, leia atentamente este manual e o manual de instalação da unidade 
interior antes de instalar o aparelho de ar condicionado.

INSTALLATIONSMANUAL

Læs af sikkerhedshensyn denne manual samt manualen til installation af indendørsenheden grundigt, før du 
installerer klimaanlægget.

INSTALLATIONSMANUAL

Läs bruksanvisningen och inomhusenhetens installationshandbok noga innan luftkonditioneringen installeras 
så att den används på ett säkert och korrekt sätt.

English

Deutsch

Français

Nederlands

Español

Italiano

E

λληνικά

Português

Dansk

Svenska

Summary of Contents for Mr. SLIM SUZ-SA100VA

Page 1: ...AL DE INSTALACIÓN Para un uso correcto y seguro lea detalladamente este manual y el manual de instalación de la unidad interior antes de instalar la unidad de aire acondicionado MANUALE DI INSTALLAZIONE Per un uso sicuro e corretto leggere attentamente il presente manuale ed il manuale d installazione dell unità interna prima di installare il condizionatore d aria EΓΧEIPIΔIO OΔHΓIΩN EΓKATAΣTAΣHΣ Γ...

Page 2: ... relocating or servicing the air conditioner use only the specified refrigerant R410A to charge the refrigerant lines Do not mix it with any other refrigerant and do not allow air to remain in the lines If air is mixed with the refrigerant then it can be the cause of abnormal high pressure in the refrigerant line and may result in an explosion and other hazards The use of any refrigerant other tha...

Page 3: ... 1 Check that the difference between the heights of the indoor and outdoor units the length of refrigerant pipe and the number of bends in the pipe are within the limits shown below Model A Pipe length one way B Height difference C Number of bends one way SUZ SA71 SA100 Max 30 m Max 30 m Max of 10 Height difference limitations are binding regardless of which unit indoor or out door is positioned h...

Page 4: ...e flared section and do flaring work again a Smooth all around f Scratch on flared plane b Inside is shining without any scratches g Cracked c Even length all around h Uneven d Too much i Bad examples e Tilted Apply a thin coat of refrigeration oil on the seat surface of pipe Fig 4 8 For connection first align the center then tighten the first 3 to 4 turns of flare nut Use tightening torque table ...

Page 5: ...e then close the gage manifold valve and stop the vacuum pump Leave it as is for one or two minutes Make sure the pointer of the gage mani fold valve remains in the same position Confirm that the pressure gage show 0 101 MPa 760 mmHg Remove the gage manifold valve quickly from the service port of the stop valve After refrigerant pipes are connected and evacuated fully open all stop valves on gas a...

Page 6: ...ply cable to the size given in the figure Be careful not to contact connecting cable with piping Caution Use care not to make miswiring Fig 5 3 Firmly tighten the terminal screws to prevent them from loosening After tightening pull the wires lightly to confirm that they do not move Warning Be sure to attach the service panel of the outdoor unit securely If it is not attached correctly it could res...

Page 7: ... 230 V Indoor unit Outdoor unit S2 S3 2 DC 12 V DC 24 V 1 A breaker with at least 3 mm contact separation in each poles shall be provided Use earth leakage breaker NV Make sure that the current leakage breaker is one compatible with higher harmonics Always use a current leakage breaker that is compatible with higher harmonics as this unit is equipped with an inverter The use of an inadequate break...

Page 8: ...oller to stop the air conditioner Note that when the extension piping is very long with a large refrigerant amount it may not be possible to perform a pump down operation In this case use refrigerant recovery equipment to collect all of the refrigerant in the system If the extension piping length for the SUZ SA100VA is 20 m or longer it will not be possible to perform a pump down operation because...

Page 9: ...uese Branch Portuguese Branch Avda do Forte 10 2799 514 Carnaxide Lisbon Portugal Avda do Forte 10 2799 514 Carnaxide Lisbon Portugal Spanish Branch Spanish Branch Carretera de Rubi 76 80 Apdo 420 08173 Sant Cugat del Valles Barcelona Spain Carretera de Rubi 76 80 Apdo 420 08173 Sant Cugat del Valles Barcelona Spain Scandinavian Branch Scandinavian Branch Hammarbacken 14 P O Box 750 SE 19127 Solle...

Reviews: