background image

RG79Y665H02

HEAD OFFICE: TOKYO BUILDING 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN

Importer:

Importer:

Mitsubishi Electric Europe B.V.

Mitsubishi Electric Europe B.V.

Capronilaan 46, 1119 NS, Schiphol Rijk, The Netherlands

Capronilaan 46, 1119 NS, Schiphol Rijk, The Netherlands

French Branch

French Branch

25, Boulevard des Bouvets, 92741 Nanterre Cedex, France

25, Boulevard des Bouvets, 92741 Nanterre Cedex, France

German Branch

German Branch

Mitsubishi-Electric-Platz 1, 40882 Ratingen, Germany

Mitsubishi-Electric-Platz 1, 40882 Ratingen, Germany

Belgian 

Belgian B

Branch

ranch

Autobaan 2, 8210 Loppem, Belgium

Autobaan 2, 8210 Loppem, Belgium

Irish Branch

Irish Branch

Westgate Business Park, Ballymount, Dublin 24, Ireland

Westgate Business Park, Ballymount, Dublin 24, Ireland

Italian Branch

Italian Branch

Centro Direzionale Colleoni, Palazzo Sirio-Ingresso 1 Viale Colleoni 7, 20864 Agrate Brianza 

Centro Direzionale Colleoni, Palazzo Sirio-Ingresso 1 Viale Colleoni 7, 20864 Agrate Brianza 

(MB), Italy

(MB), Italy

Norwegian Branch

Norwegian Branch

Gneisveien 2D, 1914 Ytre Enebakk, Norway

Gneisveien 2D, 1914 Ytre Enebakk, Norway

Portuguese Branch

Portuguese Branch

Avda. do Forte, 10, 2799-514, Carnaxide, Lisbon, Portugal

Avda. do Forte, 10, 2799-514, Carnaxide, Lisbon, Portugal

Spanish Branch

Spanish Branch

Carretera de Rubi 76-80 - Apdo. 420 08173 Sant Cugat del Valles (Barcelona), Spain

Carretera de Rubi 76-80 - Apdo. 420 08173 Sant Cugat del Valles (Barcelona), Spain

Scandinavian Branch

Scandinavian Branch

Hammarbacken 14, P.O. Box 750 SE-19127, Sollentuna, Sweden

Hammarbacken 14, P.O. Box 750 SE-19127, Sollentuna, Sweden

UK Branch

UK Branch

Travellers Lane, Hat

fi

 eld, Herts., AL10 8XB, England, U.K.

Travellers Lane, Hat

fi

 eld, Herts., AL10 8XB, England, U.K.

Polish Branch

Polish Branch

Krakowska 50, PL-32-083 Balice, Poland

Krakowska 50, PL-32-083 Balice, Poland

MITSUBISHI ELECTRIC TURKEY ELEKTR

İ

K ÜRÜNLERI A.

Ş

.

MITSUBISHI ELECTRIC TURKEY ELEKTR

İ

K ÜRÜNLERI A.

Ş

.

Ş

erifali Mah. Kale Sok. No: 41 34775 Ümraniye, 

İ

stanbul / Turkey

Ş

erifali Mah. Kale Sok. No: 41 34775 Ümraniye, 

İ

stanbul / Turkey

MITSUBISHI ELECTRIC (RUSSIA) LLC

MITSUBISHI ELECTRIC (RUSSIA) LLC

52, bld.1 Kosmodamianskaya Nab. 115054, Moscow, Russia

52, bld.1 Kosmodamianskaya Nab. 115054, Moscow, Russia

Please be sure to put the contact address/telephone number on

this manual before handing it to the customer.

This product is designed and intended for use in the residential,

commercial and light-industrial environment.

Printed in Thailand

Summary of Contents for Mr. SLIM SUZ-SA100VA

Page 1: ...AL DE INSTALACIÓN Para un uso correcto y seguro lea detalladamente este manual y el manual de instalación de la unidad interior antes de instalar la unidad de aire acondicionado MANUALE DI INSTALLAZIONE Per un uso sicuro e corretto leggere attentamente il presente manuale ed il manuale d installazione dell unità interna prima di installare il condizionatore d aria EΓΧEIPIΔIO OΔHΓIΩN EΓKATAΣTAΣHΣ Γ...

Page 2: ... relocating or servicing the air conditioner use only the specified refrigerant R410A to charge the refrigerant lines Do not mix it with any other refrigerant and do not allow air to remain in the lines If air is mixed with the refrigerant then it can be the cause of abnormal high pressure in the refrigerant line and may result in an explosion and other hazards The use of any refrigerant other tha...

Page 3: ... 1 Check that the difference between the heights of the indoor and outdoor units the length of refrigerant pipe and the number of bends in the pipe are within the limits shown below Model A Pipe length one way B Height difference C Number of bends one way SUZ SA71 SA100 Max 30 m Max 30 m Max of 10 Height difference limitations are binding regardless of which unit indoor or out door is positioned h...

Page 4: ...e flared section and do flaring work again a Smooth all around f Scratch on flared plane b Inside is shining without any scratches g Cracked c Even length all around h Uneven d Too much i Bad examples e Tilted Apply a thin coat of refrigeration oil on the seat surface of pipe Fig 4 8 For connection first align the center then tighten the first 3 to 4 turns of flare nut Use tightening torque table ...

Page 5: ...e then close the gage manifold valve and stop the vacuum pump Leave it as is for one or two minutes Make sure the pointer of the gage mani fold valve remains in the same position Confirm that the pressure gage show 0 101 MPa 760 mmHg Remove the gage manifold valve quickly from the service port of the stop valve After refrigerant pipes are connected and evacuated fully open all stop valves on gas a...

Page 6: ...ply cable to the size given in the figure Be careful not to contact connecting cable with piping Caution Use care not to make miswiring Fig 5 3 Firmly tighten the terminal screws to prevent them from loosening After tightening pull the wires lightly to confirm that they do not move Warning Be sure to attach the service panel of the outdoor unit securely If it is not attached correctly it could res...

Page 7: ... 230 V Indoor unit Outdoor unit S2 S3 2 DC 12 V DC 24 V 1 A breaker with at least 3 mm contact separation in each poles shall be provided Use earth leakage breaker NV Make sure that the current leakage breaker is one compatible with higher harmonics Always use a current leakage breaker that is compatible with higher harmonics as this unit is equipped with an inverter The use of an inadequate break...

Page 8: ...oller to stop the air conditioner Note that when the extension piping is very long with a large refrigerant amount it may not be possible to perform a pump down operation In this case use refrigerant recovery equipment to collect all of the refrigerant in the system If the extension piping length for the SUZ SA100VA is 20 m or longer it will not be possible to perform a pump down operation because...

Page 9: ...uese Branch Portuguese Branch Avda do Forte 10 2799 514 Carnaxide Lisbon Portugal Avda do Forte 10 2799 514 Carnaxide Lisbon Portugal Spanish Branch Spanish Branch Carretera de Rubi 76 80 Apdo 420 08173 Sant Cugat del Valles Barcelona Spain Carretera de Rubi 76 80 Apdo 420 08173 Sant Cugat del Valles Barcelona Spain Scandinavian Branch Scandinavian Branch Hammarbacken 14 P O Box 750 SE 19127 Solle...

Reviews: