5. Electrical work

•  Perform wiring as shown in the diagram to the lower left. (Procure the cable locally) 

(Fig. 5-2)
Make sure to use cables of the correct polarity only.

A

 Connecting cable

B

 Indoor terminal block

C

 Outdoor terminal block

D

 Always install an earth wire longer than other cables.

E

 Power supply cord

 Caution:

•  Use care not to make miswiring.
•  Firmly tighten the terminal screws to prevent then from loosening.
•  After tightening, pull the wires lightly to con

fi

 rm that they do not move.

•  Connect cable from the indoor unit correctly on the terminal-block.
•  Use the same terminal block and polarity as is used with the indoor unit.
•  For aftercare maintenance, give extra length to connecting cable.

•  Both end of connecting cable (extension wire) are peeled off. When too long, 

or connected by cutting off the middle, peel off power supply cable to the size 
given in the 

fi

 gure.

•  Be careful not to contact connecting cable with piping.

 Caution:

•  Use care not to make miswiring. (Fig. 5-3)
•  Firmly tighten the terminal screws to prevent them from loosening.
•  After tightening, pull the wires lightly to con

fi

 rm that they do not move.

 Warning:

•  Be sure to attach the service panel of the outdoor unit securely. If it is not 

attached correctly, it could result in a 

fi

 re or an electric shock due to dust, 

water, etc.

•  Tighten terminal screws securely.
•  Wiring should be done so that the power lines are not subject to tension. 

Otherwise, heat may be generated or 

fi

 re may occur.

L N

Fig. 5-2

Indoor terminal block

Earth wire (green/yellow)

Indoor/outdoor unit connecting 

wire 3-core 1.5 mm² or more

Outdoor terminal block

Power supply cord SUZ-SA71, SA100: 2.5 mm² or more

A

 Loosen terminal screw

B

 Terminal block

C

 Lead wire

Service panel

Remove 

fi

 xing 

screw to open the 

service panel.

Be sure to 

fi

 x the 

indoor/outdoor unit 

connecting wire us-

ing this cord clamp.

Fig. 5-3

 

SUZ-SA71VA2

 

SUZ-SA100VA

Summary of Contents for Mr. SLIM SUZ-SA100VA

Page 1: ...AL DE INSTALACIÓN Para un uso correcto y seguro lea detalladamente este manual y el manual de instalación de la unidad interior antes de instalar la unidad de aire acondicionado MANUALE DI INSTALLAZIONE Per un uso sicuro e corretto leggere attentamente il presente manuale ed il manuale d installazione dell unità interna prima di installare il condizionatore d aria EΓΧEIPIΔIO OΔHΓIΩN EΓKATAΣTAΣHΣ Γ...

Page 2: ... relocating or servicing the air conditioner use only the specified refrigerant R410A to charge the refrigerant lines Do not mix it with any other refrigerant and do not allow air to remain in the lines If air is mixed with the refrigerant then it can be the cause of abnormal high pressure in the refrigerant line and may result in an explosion and other hazards The use of any refrigerant other tha...

Page 3: ... 1 Check that the difference between the heights of the indoor and outdoor units the length of refrigerant pipe and the number of bends in the pipe are within the limits shown below Model A Pipe length one way B Height difference C Number of bends one way SUZ SA71 SA100 Max 30 m Max 30 m Max of 10 Height difference limitations are binding regardless of which unit indoor or out door is positioned h...

Page 4: ...e flared section and do flaring work again a Smooth all around f Scratch on flared plane b Inside is shining without any scratches g Cracked c Even length all around h Uneven d Too much i Bad examples e Tilted Apply a thin coat of refrigeration oil on the seat surface of pipe Fig 4 8 For connection first align the center then tighten the first 3 to 4 turns of flare nut Use tightening torque table ...

Page 5: ...e then close the gage manifold valve and stop the vacuum pump Leave it as is for one or two minutes Make sure the pointer of the gage mani fold valve remains in the same position Confirm that the pressure gage show 0 101 MPa 760 mmHg Remove the gage manifold valve quickly from the service port of the stop valve After refrigerant pipes are connected and evacuated fully open all stop valves on gas a...

Page 6: ...ply cable to the size given in the figure Be careful not to contact connecting cable with piping Caution Use care not to make miswiring Fig 5 3 Firmly tighten the terminal screws to prevent them from loosening After tightening pull the wires lightly to confirm that they do not move Warning Be sure to attach the service panel of the outdoor unit securely If it is not attached correctly it could res...

Page 7: ... 230 V Indoor unit Outdoor unit S2 S3 2 DC 12 V DC 24 V 1 A breaker with at least 3 mm contact separation in each poles shall be provided Use earth leakage breaker NV Make sure that the current leakage breaker is one compatible with higher harmonics Always use a current leakage breaker that is compatible with higher harmonics as this unit is equipped with an inverter The use of an inadequate break...

Page 8: ...oller to stop the air conditioner Note that when the extension piping is very long with a large refrigerant amount it may not be possible to perform a pump down operation In this case use refrigerant recovery equipment to collect all of the refrigerant in the system If the extension piping length for the SUZ SA100VA is 20 m or longer it will not be possible to perform a pump down operation because...

Page 9: ...uese Branch Portuguese Branch Avda do Forte 10 2799 514 Carnaxide Lisbon Portugal Avda do Forte 10 2799 514 Carnaxide Lisbon Portugal Spanish Branch Spanish Branch Carretera de Rubi 76 80 Apdo 420 08173 Sant Cugat del Valles Barcelona Spain Carretera de Rubi 76 80 Apdo 420 08173 Sant Cugat del Valles Barcelona Spain Scandinavian Branch Scandinavian Branch Hammarbacken 14 P O Box 750 SE 19127 Solle...

Reviews: