6. Electrical work

7. Maintenance

7.1. Gas charge (Fig. 7-1)

1.  Connect gas cylinder to the service port of stop valve (3-way).

2. 

Execute air purge of the pipe (or hose) coming from refrigerant gas cylinder.

3.  Replenish specified amount of refrigerant, while running the air condition

-

er for cooling.

Note:

In case of adding refrigerant, comply with the quantity specified for the refrig

-

erating cycle.

 Caution:

•  Do not discharge the refrigerant into the atmosphere.

Take care not to discharge refrigerant into the atmosphere during installa-
tion, reinstallation, or repairs to the refrigerant circuit.

•  For additional charging, charge the refrigerant from liquid phase of the gas 

cylinder.

  If the refrigerant is charged from the gas phase, composition change may 

occur in the refrigerant inside the cylinder and the outdoor unit. In this case, 
ability of the refrigerating cycle decreases or normal operation can be im-

possible. However, charging the liquid refrigerant all at once may cause the 

compressor to be locked. Thus, charge the refrigerant slowly.

To maintain the high pressure of the gas cylinder, warm the gas cylinder with warm 

water (under 40°C) during cold season. But never use naked fire or steam.

6.2. Field electrical wiring

Outdoor unit model

SUZ-KA25/KA35

SUZ-KA35 *3

SUZ-KA50/KA60/KA71

Outdoor unit power supply

~/N (single), 50 Hz, 230 V

~/N (single), 50 Hz, 230 V

~/N (single), 50 Hz, 230 V

Outdoor unit input capacity Main switch (Breaker)

*1

10 A

16 A

20 A

Wiring 

Wire No. × 

size (mm

2

)

Outdoor unit power supply

2 × Min. 1.5

2 × Min. 2.0

2 × Min. 2.5

Outdoor unit power supply earth

1 × Min. 1.5

1 × Min. 2.0

1 × Min. 2.5

Indoor unit-Outdoor unit

3 × 1.5 (Polar)

3 × 1.5 (Polar)

3 × 1.5 (Polar)

Indoor unit-Outdoor unit earth

1 × Min. 1.5

1 × Min. 1.5

1 × Min. 1.5

Circuit

 rating

Outdoor unit L-N

*2

230 VAC

230 VAC

230 VAC

Indoor unit-Outdoor unit S1-S2

*2

230 VAC

230 VAC

230 VAC

Indoor unit-Outdoor unit S2-S3

*2

12 VDC – 24 VDC

12 VDC – 24 VDC

12 VDC – 24 VDC

*1. A breaker with at least 3 mm contact separation in each poles shall be provided. Use earth leakage breaker (NV).

 

Make sure that the current leakage breaker is one compatible with higher harmonics.

 

Always use a current leakage breaker that is compatible with higher harmonics as this unit is equipped with an inverter.

 

The use of an inadequate breaker can cause the incorrect operation of inverter.

*2. The figures are NOT always against the ground.

S3 terminal has 24 VDC against S2 terminal. However between S3 and S1, these terminals are NOT electrically insulated by the transformer or other device.

*3.  In case of PEAD-RP35JA series combination.

Notes: 1. Wiring size must comply with the applicable local and national code.

2. Power supply cords and Indoor/Outdoor unit connecting cords shall not be lighter than polychloroprene sheathed flexible cord. (Design 60245 IEC 57)

3. Install an earth longer than other cables.

Outdoor Unit

3 poles isolator

230 V

Single phase

Isolator

Indoor Unit

 Warning:

There is high voltage potential on the S3 terminal caused by electrical circuit design that has no electrical insulation between power line and communication 
signal line. Therefore, please turn off the main power supply when servicing. And do not touch the S1, S2, S3 terminals when the power is energized. If isolator 
should be used between indoor unit and outdoor unit, please use 3-poles type.

A

 Indoor unit

H

 Refrigerant gas cylinder for R410A with siphon

B

 Union

I

 Refrigerant (liquid)

C

 Liquid pipe

J

 Electronic scale for refrigerant charging

D

 Gas pipe

K

 Charge hose (for R410A)

E

 Stop valve

L

 Gauge manifold valve (for R410A)

F

 Outdoor unit

M

 Service port

G

 Refrigerant gas cylinder 

operating valve

B

A

G

H

K

L

M

I

J

C
D

E

F

Fig. 7-1

Never splice the power cable or the indoor-outdoor connection cable, otherwise it may result in a smoke, a fire or communication failure.

01_RG79Y757H01_EN.indd   7

7/23/2015   3:48:01 PM

Summary of Contents for Mr.Slim SUZ-KA25VA5

Page 1: ...ente este manual y el manual de instalación de la unidad interior antes de instalar la unidad de aire acondicionado MANUALE DI INSTALLAZIONE Per un uso sicuro e corretto leggere attentamente il presente manuale ed il manuale d installazione dell unità interna prima di installare il condizionatore d aria EΓΧEIPIΔIO OΔHΓIΩN EΓKATAΣTAΣHΣ Για σωστή και ασφαλή χρήση διαβάστε προσεκτικά αυτό το εγχειρίδ...

Page 2: ...hen installing or relocating or servicing the air conditioner use only the specified refrigerant R410A to charge the refrigerant lines Do not mix it with any other refrigerant and do not allow air to remain in the lines If air is mixed with the refrigerant then it can be the cause of abnormal high pressure in the refrigerant line and may result in an explosion and other hazards The use of any refr...

Page 3: ...stall the outdoor unit with its air inlet side facing the wall To prevent exposure to wind it is recommended to install a baffle board on the air outlet side of the outdoor unit Units should be installed by licensed contractor accordingly to local code re quirement Fig 4 1 4 Drain piping for outdoor unit Fig 4 1 4 1 Accessories Check the following parts before installation Outdoor unit 1 Drain soc...

Page 4: ...KA60 For liquid 6 35 1 4 0 8 mm 8 mm For gas 15 88 5 8 0 8 mm 8 mm SUZ KA71 For liquid 9 52 3 8 0 8 mm 8 mm For gas 15 88 5 8 1 0 mm 8 mm 2 Ensure that the 2 refrigerant pipes are well insulated to prevent condensation 3 Refrigerant pipe bending radius must be 100 mm or more Caution Using careful insulation of specified thickness Excessive thickness prevents storage behind the indoor unit and smal...

Page 5: ...een the indoor and the outdoor units After refrigerant pipes are connected and evacuated fully open all stop valves on gas and liquid pipe sides Operating without fully opening lowers the performance and causes trouble Pipe length 7 m maximum No gas charge is needed Pipe length exceeding 7 m Charge the prescribed amount of gas Remove the service port cap of the stop valve on the side of the outdoo...

Page 6: ...n terminal screws securely Wiring should be done so that the power lines are not subject to tension Otherwise heat may be generated or fire may occur A B C D S3 S3 S2 S1 1 S 2 S L N 2 1 E B C L N A E D C Fig 6 1 Fig 6 2 Fig 6 4 A Indoor unit B Outdoor unit C Wired main switch Earth leakage breaker D Earth E Remote controller For Power supply Indoor terminal block Earth wire green yellow Indoor out...

Page 7: ...or unit Outdoor unit S1 S2 2 230 VAC 230 VAC 230 VAC Indoor unit Outdoor unit S2 S3 2 12 VDC 24 VDC 12 VDC 24 VDC 12 VDC 24 VDC 1 A breaker with at least 3 mm contact separation in each poles shall be provided Use earth leakage breaker NV Make sure that the current leakage breaker is one compatible with higher harmonics Always use a current leakage breaker that is compatible with higher harmonics ...

Page 8: ...stop the air conditioner Push the ON OFF button on the remote controller to stop the air conditioner Note that when the extension piping is very long with a large refrigerant amount it may not be possible to perform a pump down operation In this case use refrigerant recovery equipment to collect all of the refrigerant in the system 7 Turn off the power supply circuit breaker remove the gauge manif...

Page 9: ...r for undernevnte klimaanlegg og varmepumper ved bruk i boliger samt kommersielle og lettindustrielle miljøer MITSUBISHI ELECTRIC SUZ KA25VA SUZ KA35VA SUZ KA50VA SUZ KA60VA SUZ KA71VA 1 2 3 9 Note Its serial number is on the nameplate of the product Hinweis Die Seriennummer befindet sich auf dem Kennschild des Produkts Remarque Le numéro de série de l appareil se trouve sur la plaque du produit O...

Page 10: ... brännskador eller köldskador Stoppa aldrig batterier i munnen de kan sväljas av misstag Om ett batteri sväljs kan det leda till kvävning och eller förgiftning Montera enheten på ett stadigt underlag för att förhindra höga driftljud och vibrationer Ljudmätningar har utförts i enlighet med JIS C9612 JIS B8616 ISO 5151 T1 och ISO 13523 T1 NEDERLANDS Het Engels is het origineel De andere taalversies ...

Page 11: ... address telephone number on this manual before handing it to the customer This product is designed and intended for use in the residential commercial and light industrial environment The product at hand is based on the following EU regulations Low Voltage Directive 2006 95 EC Electromagnetic Compatibility Directive 2004 108 EC Machinery Directive 2006 42 EC RoHS Directive 2011 65 EU Energy relate...

Reviews: