Mitsubishi Electric Mr.Slim SUZ-KA25VA5 Installation Manual Download Page 3

3

50

360

500

175

330

40

81

840

A

D

C

A

B

285 

40 

304 - 325 

800 

500 

150

400 

44 

69 

3. Installation diagram

Fig. 3-1

3.1. Outdoor unit (Fig. 3-1)

Ventilation and service space

 

SUZ-KA25VA5
SUZ-KA35VA5

A

 100 mm or more

B

 350 mm or more

C

 Basically open 100 mm or more without any obstruction in front and on both 

sides of the unit.

D

 200 mm or more (Open two sides of left, right, or rear side.)

 

SUZ-KA50VA5
SUZ-KA60VA5
SUZ-KA71VA5

A

 100 mm or more

B

 350 mm or more

C

 500 mm or more

When the piping is to be attached to a wall containing metals (tin plated) or metal 

netting, use a chemically treated wooden piece 20 mm or thicker between the wall 
and the piping or wrap 7 to 8 turns of insulation vinyl tape around the piping.

Note:
When operating the air conditioner in low outside temperature, be sure to fol-
low the instructions described below.

•   Never install the outdoor unit in a place where its air inlet/outlet side may be ex

-

posed directly to wind.

•   To prevent exposure to wind, install the outdoor unit with its air inlet side facing 

the wall.

•   To prevent exposure to wind, it is recommended to install a baffle board on the air 

outlet side of the outdoor unit.

Units should be installed by licensed contractor accordingly to local code re-
quirement.

Fig. 4-1

4. Drain piping for outdoor unit (Fig. 4-1)

4.1. Accessories

Check the following parts before installation.

<Outdoor unit>

1

Drain socket 

1

•  Provide drain piping before indoor and outdoor piping connection. (It will be hard 

to install drain socket 

1

 if indoor and outdoor piping connection is conducted prior 

to drain piping as outdoor unit becomes immovable.)

•  Connect  the  drain  hose    (obtainable  at  a  store,  inside  diameter:  15  mm)  as 

shown in the figure for drainage.

•  Make sure to provide drain piping with a downhill grade for easy drain flow.

Note:
Do not use the drain socket 

1

 in the cold region. Drain may freeze and it 

makes the fan stop.

(mm)

 

SUZ-KA50VA5

 SUZ-KA60VA5
 SUZ-KA71VA5

A

C

A

C

B

(mm)

 SUZ-KA25VA5

 SUZ-KA35VA5

Drain socket 

Drain hose 

Drainage hole (

{

42)

(In case of Heater models 

{

33)

Air inlet

Air outlet

2-10 mm × 21 mm slot

344.5 

Air inlet

417.5

Air outlet

2-10 mm × 21 mm slot

Air inlet

Drainage hole 

(

{

42)

01_RG79Y757H01_EN.indd   3

7/23/2015   3:48:00 PM

Summary of Contents for Mr.Slim SUZ-KA25VA5

Page 1: ...ente este manual y el manual de instalación de la unidad interior antes de instalar la unidad de aire acondicionado MANUALE DI INSTALLAZIONE Per un uso sicuro e corretto leggere attentamente il presente manuale ed il manuale d installazione dell unità interna prima di installare il condizionatore d aria EΓΧEIPIΔIO OΔHΓIΩN EΓKATAΣTAΣHΣ Για σωστή και ασφαλή χρήση διαβάστε προσεκτικά αυτό το εγχειρίδ...

Page 2: ...hen installing or relocating or servicing the air conditioner use only the specified refrigerant R410A to charge the refrigerant lines Do not mix it with any other refrigerant and do not allow air to remain in the lines If air is mixed with the refrigerant then it can be the cause of abnormal high pressure in the refrigerant line and may result in an explosion and other hazards The use of any refr...

Page 3: ...stall the outdoor unit with its air inlet side facing the wall To prevent exposure to wind it is recommended to install a baffle board on the air outlet side of the outdoor unit Units should be installed by licensed contractor accordingly to local code re quirement Fig 4 1 4 Drain piping for outdoor unit Fig 4 1 4 1 Accessories Check the following parts before installation Outdoor unit 1 Drain soc...

Page 4: ...KA60 For liquid 6 35 1 4 0 8 mm 8 mm For gas 15 88 5 8 0 8 mm 8 mm SUZ KA71 For liquid 9 52 3 8 0 8 mm 8 mm For gas 15 88 5 8 1 0 mm 8 mm 2 Ensure that the 2 refrigerant pipes are well insulated to prevent condensation 3 Refrigerant pipe bending radius must be 100 mm or more Caution Using careful insulation of specified thickness Excessive thickness prevents storage behind the indoor unit and smal...

Page 5: ...een the indoor and the outdoor units After refrigerant pipes are connected and evacuated fully open all stop valves on gas and liquid pipe sides Operating without fully opening lowers the performance and causes trouble Pipe length 7 m maximum No gas charge is needed Pipe length exceeding 7 m Charge the prescribed amount of gas Remove the service port cap of the stop valve on the side of the outdoo...

Page 6: ...n terminal screws securely Wiring should be done so that the power lines are not subject to tension Otherwise heat may be generated or fire may occur A B C D S3 S3 S2 S1 1 S 2 S L N 2 1 E B C L N A E D C Fig 6 1 Fig 6 2 Fig 6 4 A Indoor unit B Outdoor unit C Wired main switch Earth leakage breaker D Earth E Remote controller For Power supply Indoor terminal block Earth wire green yellow Indoor out...

Page 7: ...or unit Outdoor unit S1 S2 2 230 VAC 230 VAC 230 VAC Indoor unit Outdoor unit S2 S3 2 12 VDC 24 VDC 12 VDC 24 VDC 12 VDC 24 VDC 1 A breaker with at least 3 mm contact separation in each poles shall be provided Use earth leakage breaker NV Make sure that the current leakage breaker is one compatible with higher harmonics Always use a current leakage breaker that is compatible with higher harmonics ...

Page 8: ...stop the air conditioner Push the ON OFF button on the remote controller to stop the air conditioner Note that when the extension piping is very long with a large refrigerant amount it may not be possible to perform a pump down operation In this case use refrigerant recovery equipment to collect all of the refrigerant in the system 7 Turn off the power supply circuit breaker remove the gauge manif...

Page 9: ...r for undernevnte klimaanlegg og varmepumper ved bruk i boliger samt kommersielle og lettindustrielle miljøer MITSUBISHI ELECTRIC SUZ KA25VA SUZ KA35VA SUZ KA50VA SUZ KA60VA SUZ KA71VA 1 2 3 9 Note Its serial number is on the nameplate of the product Hinweis Die Seriennummer befindet sich auf dem Kennschild des Produkts Remarque Le numéro de série de l appareil se trouve sur la plaque du produit O...

Page 10: ... brännskador eller köldskador Stoppa aldrig batterier i munnen de kan sväljas av misstag Om ett batteri sväljs kan det leda till kvävning och eller förgiftning Montera enheten på ett stadigt underlag för att förhindra höga driftljud och vibrationer Ljudmätningar har utförts i enlighet med JIS C9612 JIS B8616 ISO 5151 T1 och ISO 13523 T1 NEDERLANDS Het Engels is het origineel De andere taalversies ...

Page 11: ... address telephone number on this manual before handing it to the customer This product is designed and intended for use in the residential commercial and light industrial environment The product at hand is based on the following EU regulations Low Voltage Directive 2006 95 EC Electromagnetic Compatibility Directive 2004 108 EC Machinery Directive 2006 42 EC RoHS Directive 2011 65 EU Energy relate...

Reviews: