background image

MONTÖR 

İ

Ç

İ

N

ДЛЯ

 

УСТАНОВИТЕЛЯ

TIL INSTALLATØREN

FÖR INSTALLATÖREN

PARA O INSTALADOR

ΓΙΑ

 

ΑΥΤΟΝ

 

ΠΟΥ

 

ΚΑΝΕΙ

 

ΤΗΝ

 

ΕΓΚΑΤΑΣΤΑΣΗ

PER L’INSTALLATORE

PARA EL INSTALADOR

VOOR DE INSTALLATEUR

POUR L’INSTALLATEUR

FÜR INSTALLATEURE

FOR INSTALLER

Air-Conditioners

SUZ-KA25, KA35, KA50, KA60, KA71VA2
SUZ-KA25, KA35VAH

INSTALLATION MANUAL

For safe and correct use, read this manual and the indoor unit installation manual thoroughly before installing 
the air-conditioner unit.

РУКОВОДСТВО

 

ПО

 

УСТАНОВКЕ

Для

 

обеспечения

 

безопасной

 

и

 

надлежащей

 

эксплуатации

 

внимательно

 

прочтите

 

данное

 

руководство

 

и

 

руководство

 

по

 

установке

 

внутреннего

 

прибора

 

перед

 

установкой

 

кондиционера

.

INSTALLATIONSHANDBUCH

Aus Sicherheitsgründen und zur richtigen Verwendung vor der Installation die vorliegende Bedienungsanleitung 
und die Installationsanleitung der Innenanlage gründlich durchlesen die Klimaanlage.

MANUEL D’INSTALLATION

Avant d’installer le climatiseur, lire attentivement ce manuel, ainsi que le manuel d’installation de l’appareil 
intérieur pour une utilisation sûre et correcte.

INSTALLATIEHANDLEIDING

Lees deze handleiding en de installatiehandleiding van het binnenapparaat zorgvuldig door voordat u met het 
installeren van de airconditioner begint.

MANUAL DE INSTALACIÓN

Para un uso correcto y seguro, lea detalladamente este manual y el manual de instalación de la unidad interior 
antes de instalar la unidad de aire acondicionado.

MANUALE DI INSTALLAZIONE

Per un uso sicuro e corretto, leggere attentamente il presente manuale ed il manuale d’installazione dell’unità 
interna prima di installare il condizionatore d’aria.

E

ΓΧ

EIPI

Δ

IO O

Δ

H

Γ

I

Ω

N E

Γ

KATA

Σ

TA

Σ

H

Σ

Για

 

σωστή

 

και

 

ασφαλή

 

χρήση

διαβάστε

 

προσεκτικά

 

αυτό

 

το

 

εγχειρίδιο

 

καθώς

 

και

 

το

 

εγχειρίδιο

 

εγκατάστασης

 

της

 

εσωτερικής

 

μονάδας

προτού

 

εγκαταστήσετε

 

τη

 

μονάδα

 

του

 

κλιματιστικού

.

MANUAL DE INSTALAÇÃO

Para uma utilização segura e correcta, leia atentamente este manual e o manual de instalação da unidade 
interior antes de instalar o aparelho de ar condicionado.

INSTALLATIONSMANUAL

Læs af sikkerhedshensyn denne manual samt manualen til installation af indendørsenheden grundigt, før du 
installerer klimaanlægget.

INSTALLATIONSMANUAL

Läs bruksanvisningen och inomhusenhetens installationshandbok noga innan luftkonditioneringen installeras 
så att den används på ett säkert och korrekt sätt.

MONTAJ ELK

İ

TABI

Emniyetli ve do

ğ

ru kullanım için, klima cihazını monte etmeden önce bu kılavuzu ve iç ünite montaj kılavuzunu 

tamamıyla okuyun.

Türkçe

Русский

English

Deutsch

Français

Nederlands

Español

Italiano

E

λληνικά

Português

Dansk

Svenska

Summary of Contents for Mr. Slim SUZ-KA25

Page 1: ...het installeren van de airconditioner begint MANUAL DE INSTALACIÓN Para un uso correcto y seguro lea detalladamente este manual y el manual de instalación de la unidad interior antes de instalar la unidad de aire acondicionado MANUALE DI INSTALLAZIONE Per un uso sicuro e corretto leggere attentamente il presente manuale ed il manuale d installazione dell unità interna prima di installare il condiz...

Page 2: ...ing down the refrigerant stop the compressor before discon necting the refrigerant pipes The compressor may burst if air etc get into it Caution Perform grounding Do not connect the ground wire to a gas pipe water pipe arrester or tele phone ground wire Defective grounding could cause an electric shock Do not install the unit in a place where an inflammable gas leaks If gas leaks and accumulates i...

Page 3: ...air inlet side facing the wall To prevent exposure to wind it is recommended to install a baffle board on the air outlet side of the outdoor unit Units should be installed by licensed contractor accordingly to local code re quirement SUZ KA50 KA60VA2 Air outlet 2 10 mm 21 mm slot Air inlet 285 40 344 5 304 325 800 500 150 400 44 Drainage hole W42 In case of Heater models W33 69 Drain hose Drain so...

Page 4: ...1 4 0 8 mm 8 mm For gas 12 7 1 2 0 8 mm 8 mm SUZ KA60 For liquid 6 35 1 4 0 8 mm 8 mm For gas 15 88 5 8 0 8 mm 8 mm SUZ KA71 For liquid 9 52 3 8 0 8 mm 8 mm For gas 15 88 5 8 1 0 mm 8 mm 2 Ensure that the 2 refrigerant pipes are well insulated to prevent condensation 3 Refrigerant pipe bending radius must be 100 mm or more Caution Using careful insulation of specified thickness Excessive thickness...

Page 5: ...r the vacuum pump with the function to prevent the back flow Gauge manifold valve for R410A Pressure gauge for R410A Compound pressure gauge for R410A 0 101 MPa 760 mmHg Handle Low Handle High Window Charge hose for R410A Vacuum pump Adapter for preventing the back flow Charge hose for R410A Service port Stop valve PURGING PROCEDURES Connect the refrigerant pipes both the liquid and gas pipes betw...

Page 6: ...er than other cables E Power supply cord Caution Use care not to make miswiring Firmly tighten the terminal screws to prevent then from loosening After tightening pull the wires lightly to confirm that they do not move Connect cable from the indoor unit correctly on the terminal block Use the same terminal block and polarity as is used with the indoor unit For aftercare maintenance give extra leng...

Page 7: ...1 Min 1 5 1 Min 2 0 1 Min 2 5 Indoor unit Outdoor unit 3 1 5 Polar 3 1 5 Polar 3 1 5 Polar Indoor unit Outdoor unit earth 1 Min 1 5 1 Min 1 5 1 Min 1 5 Circuit rating Outdoor unit L N 2 AC 230 V AC 230 V AC 230 V Indoor unit Outdoor unit S1 S2 2 AC 230 V AC 230 V AC 230 V Indoor unit Outdoor unit S2 S3 2 DC 12 V DC 24 V DC 12 V DC 24 V DC 12 V DC 24 V 1 A breaker with at least 3 mm contact separat...

Page 8: ... RG79D664H01 Printed in Thailand Please be sure to put the contact address telephone number on this manual before handing it to the customer This product is designed and intended for use in the residential commercial and light industrial environment The product at hand is based on the following EU regulations Low Voltage Directive 2006 95 EC Electromagnetic Compatibility Directive 2004 108 EC ...

Reviews: