background image

EN-1

EN

1. Safety Precautions ............................................................................. 1

2. Parts Names ....................................................................................... 2

3. Operation  ........................................................................................... 5

4. Timer................................................................................................. 12

5. Care and Cleaning............................................................................ 13

1. Safety Precautions

6. Emergency Operation for Wireless Remote-controller ..................... 14

7. Trouble Shooting .............................................................................. 14

8. Installation, relocation and inspection............................................... 16

9. Specifications

 ................................................................................... 17

Symbols used in the text

 Warning:

Describes precautions that should be observed to prevent danger of injury 

or death to the user.

 Caution:

Describes precautions that should be observed to prevent damage to 

the unit.

Symbols used in the illustrations

 :  Indicates a part which must be grounded.

Note:

The phrase “Wired remote controller” in this operation manual refers only to the PAR-33MAA. If you need any information for the other 

remote controller, please refer to the instruction book included in this box.

This symbol mark is for EU countries only.

This symbol mark is according to the directive 2012/19/EU Article 14 Information for users and Annex IX, and/or to the direc-

tive 2006/66/EC Article 20 Information for end-users and Annex II.

Your MITSUBISHI ELECTRIC product is designed and manufactured with high quality materials and components which can be 

recycled and/or reused. This symbol means that electrical and electronic equipment, batteries and accumulators, at their end-of-life, 

should be disposed of separately from your household waste. If a chemical symbol is printed beneath the symbol (Fig. 1), this chemi-

cal symbol means that the battery or accumulator contains a heavy metal at a certain concentration. 

This will be indicated as follows: Hg: mercury (0.0005%), Cd: cadmium (0.002%), Pb: lead (0.004%) 
In the European Union there are separate collection systems for used electrical and electronic products, batteries and accumulators.

Please, dispose of this equipment, batteries and accumulators correctly at your local community waste collection/recycling centre.

Please, help us to conserve the environment we live in! 

Note

Fig. 1

MEANINGS OF SYMBOLS DISPLAYED ON THE UNIT

WARNING

(Risk of fire)

This mark is for R32 refrigerant only. Refrigerant type is written on nameplate of outdoor unit.

In case that refrigerant type is R32, this unit uses a flammable refrigerant.

If refrigerant leaks and comes in contact with fire or heating part, it will create harmful gas and there is risk of fire.

Read the OPERATION MANUAL carefully before operation.

Service personnel are required to carefully read the OPERATION MANUAL and INSTALLATION MANUAL before operation.

Further information is available in the OPERATION MANUAL, INSTALLATION MANUAL, and the like.

► Before installing the unit, make sure you read all the “Safety Precau

-

tions”.

► The “Safety Precautions” provide very important points regarding safe

-

ty. Make sure you follow them.

► Please report to or take consent by the supply authority before connec

-

tion to the system.

 Warning:

•   There appliances are not accessible to the general public.

•   The unit must not be installed by the user. Ask the dealer or an authorized 

company to install the unit. If the unit is installed improperly, water leakage, 

electric shock or fire may result. 

•   Do not stand on, or place any items on the unit. 

•   Do not splash water over the unit and do not touch the unit with wet hands. 

An electric shock may result. 

•   Do not spray combustible gas close to the unit. Fire may result. 

•   Do not place a gas heater or any other open-flame appliance where it will be 

exposed to the air discharged from the unit. Incomplete combustion may result. 

•   Do not remove the front panel or the fan guard from the outdoor unit when 

it is running. 

•   When you notice exceptionally abnormal noise or vibration, stop operation, 

turn off the power switch, and contact your dealer. 

•   Never insert fingers, sticks etc. into the intakes or outlets. 

• 

 If you detect odd smells, stop using the unit, turn off the power switch and 

consult your dealer. Otherwise, a breakdown, electric shock or fire may result. 

•   This air conditioner is NOT intended for use by children or infirm persons 

without supervision. 

•   Young children must be supervised to ensure that they do not play with the 

air conditioner. 

•   If the refrigeration gas blows out or leaks, stop the operation of the air condi

-

tioner, thoroughly ventilate the room, and contact your dealer.

• 

 This appliance is intended to be used by expert or trained users in shops, in 

light industry and on farms, or for commercial use by lay persons.

•   This appliance can be used by children aged from 8 years and above and 

persons with reduced physical, sensory or mental capabilities or lack of 

experience and knowledge if they have been given supervision or instruc-

tion concerning use of the appliance in a safe way and understand the haz

-

ards involved. Children shall not play with the appliance. Cleaning and user 

maintenance shall not be made by children without supervision.

•   This appliance is not intended for use by persons (including children) with 

reduced physical, sensory or mental capabilities, or lack of experience and 

knowledge, unless they have been given supervision or instruction con-

cerning use of the appliance by a  person responsible for their safety.

•   Children should be supervised to ensure that they do not play with the ap

-

pliances.

•   When installing or relocating, or servicing the air conditioner, use only the 

specified refrigerant written on outdoor unit to charge the refrigerant lines. 

Do not mix it with any other refrigerant and do not allow air to remain in the 

lines.

  

If air is mixed with the refrigerant, then it can be the cause of abnormal high 

pressure in the refrigerant line, and may result in an explosion and other 

hazards.

   The use of any refrigerant other than that specified for the system will cause 

mechanical failure or system malfunction or unit breakdown. In the worst 

case, this could lead to a serious impediment to securing product safety.

•   This unit should be installed in rooms which exceed the floor space speci

-

fied in outdoor unit installation manual.

  

Refer to outdoor unit installation manual.

•   Do not use means to accelerate the defrosting process or to clean, other 

than those recommended by the manufacturer.

•   The appliance shall be stored in a room without continuously operating ig

-

nition sources (for example: open flames, an operating gas appliance or an 

operating electric heater).

•   Do not pierce or burn.

•   Be aware that refrigerants may not contain an odour.

Contents

For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit.

BH79A366W01_01En.indd   1

2018/06/11   15:53:42

Summary of Contents for Mr. Slim SLZ-M15

Page 1: ...škai Hrvatski Srpski Українська PROVOZNÍ PŘÍRUČKA NÁVOD NA OBSLUHU HASZNÁLATI KÉZIKÖNYV NAVODILA ZA UPORABO MANUAL DE UTILIZARE KASUTUSJUHEND LIETOŠANAS ROKASGRĀMATA NAUDOJIMO VADOVAS PRIRUČNIK ZA RUKOVANJE UPUTSTVO ZA RUKOVANJE ПОСІБНИК З ЕКСПЛУАТАЦІЇ PER L UTENTE VOOR DE GEBRUIKER PARA EL USUARIO FÜR BENUTZER POUR L UTILISATEUR FÖR ANVÄNDAREN TIL BRUGER PARA O UTILIZADOR ΓΙΑ ΤΟΝ ΧΡΗΣΤΗ KULLANICI...

Page 2: ...d do not touch the unit with wet hands An electric shock may result Do not spray combustible gas close to the unit Fire may result Do not place a gas heater or any other open flame appliance where it will be exposed to the air discharged from the unit Incomplete combustion may result Do not remove the front panel or the fan guard from the outdoor unit when it is running When you notice exceptional...

Page 3: ...menu 5 Backlit LCD Operation settings will appear When the backlight is off pressing any button turns the backlight on and it will stay lit for a certain period of time depending on the screen When the backlight is off pressing any button turns the backlight on and does not perform its function except for the ON OFF button 6 ON OFF lamp This lamp lights up in green while the unit is in operation I...

Page 4: ...played for explanation Fri Mode Temp Fan Room Cool Set temp Basic mode Fri Cool Mode Temp Fan Set temp 4 3 2 1 5 6 7 8 9 0 1 3 4 7 2 3 4 5 6 8 9 2 1 5 3 Appears when the On Off timer Night setback or Auto off timer func tion is enabled appears when the timer is disabled by the centralized control system 4 Appears when the Weekly timer is enabled 5 Appears while the units are operated in the energy...

Page 5: ...direct is selected the vane setting is set to Auto Set Temperature buttons Weekly timer ON OFF button Set Time button Sets the time Airflow button Changes up down airflow direction Mode button Changes operation mode Timer ON button Timer OFF button OFF ON button Fan Speed button Changes fan speed SET SEND button CANCEL button Up Down buttons Menu button i see button Reset button Remote controller ...

Page 6: ...forming the initial automatic check The indoor unit beeps to confirm that the signal transmitted from the remote controller has been received Signals can be received up to approximately 7 meters in a direct line from the indoor unit in an area 45 to the left and right of the unit However illumination such as fluorescent lights and strong light can affect the ability of the indoor unit to receive s...

Page 7: ...that does not operate may get warm or the sound of refrigerant flowing may be heard they are not malfunction The reason is that the refrigerant continuously flows into it Automatic operation According to a set temperature cooling operation starts if the room temperature is too hot and heating operation starts if the room temperature is too cold During automatic operation if the room temperature ch...

Page 8: ...Main menu Vane Louver Vent Lossnay High power Timer Weekly timer OU silent mode Cursor Navigating through the pages F1 F2 F3 F4 Main Main display Cursor Page Main menu Vane Louver Vent Lossnay High power Timer Weekly timer OU silent mode page Saving the settings F1 F2 F3 F4 OU silent mode Mon Tue Wed Thu Fri Sat Sun Start Stop Silent Setting display day Exiting the Main menu screen F1 F2 F3 F4 Coo...

Page 9: ...emote controller Fixed The airflow direction of this outlet is fixed in particular direction When it is cold because of direct airflow the airflow direction can be fixed horizontally to avoid direct airflow How to set the fixed up down air direction Notes This function cannot be set depending on the outdoor unit to be connected For SLZ M FA series only the particular outlet can be fixed to certain...

Page 10: ... this setting is more horizontal than the airflow direction for the Step 1 setting in order to reduce a drafty feeling The draft reduction can be set for only 1 vane Vane setting Press the SELECT button to save the settings A screen will appear that indicates the setting information is being trans mitted The setting changes will be made to the selected outlet The screen will automatically return t...

Page 11: ...mation 1 Select Maintenance from the Main menu refer to page 7 and press the SELECT button 2 Select 3D i See sensor with the F1 or F2 button and press the SELECT button F1 F2 F3 F4 3D i See sensor Cursor Setting display Air distribution Energy saving option Seasonal airflow 3 6 2 Air distribution F1 F2 F3 F4 Air distribution Input display Cur Address Check Ref address Unit No Identify unit Check b...

Page 12: ...imately 30 of the maxi mum occupancy rate energy saving operation equal to 1 C is performed No occupancy Auto OFF If there are no persons in the room for the set amount of time 60 180 minutes the operation is automatically stopped 2 When No occupancy energy save or Room occupancy energy save is selected Select the setting with the F4 button OFF Cooling only Heating only Cooling Heating OFF After c...

Page 13: ...roller The weekly schedule can be set to four operation patterns for each day of the week The settings include the on and off times and the set temperature Editing mode 1 Switching to the editing mode 1 Press the button when the unit is operating or stopped blinks Fig 1 2 Selecting the setting pattern 1 Press the button to select the setting pattern number Each time the button is pressed the patte...

Page 14: ...or by using a heat source such as an electric heater this may warp them Do not wash the filters in hot water above 50 C as this may warp them Make sure that the air filters are always installed Operating the unit without air filters can cause malfunction Caution Before you start cleaning stop operation and turn OFF the power supply Indoor units are equipped with filters to remove the dust of sucke...

Page 15: ...M FA series when the set room temperature is reached during cooling mode the fan operates at the lowest speed Airflow direction changes during operation or airflow direction cannot be set During heating mode the vanes automatically move to the horizontal airflow direction when the airflow temperature is low or during defrosting mode When the airflow direction is changed the vanes always move up an...

Page 16: ...erates and then stops Wait approximately 3 minutes The vanes do not move or the indoor unit does not respond to input from the wireless remote controller The junction wire connectors of the vane motor and signal receiver may not be connected correctly Have an installer check the connections The colors of the male and female sections of the junction wire connectors must match Noise is louder than s...

Page 17: ...easons the capacity may be lowered due to dirt inside the unit Depending upon the conditions of use an odor may be generated or dirt dust etc may prevent proper drainage It is recommended to apply inspection and maintenance charged by a specialist in addition to normal maintenance Consult your dealer Also consider operation sound Do not put an object around the air outlet of the outdoor unit It ma...

Page 18: ...7 0 20 0 24 0 32 0 43 Dimension Height mm 245 10 Dimension Width mm 570 625 Dimension Depth mm 570 625 Fan airflow rate Low Middle High m3 min 6 0 6 5 7 0 6 5 7 5 8 5 6 5 8 0 9 5 7 0 9 0 11 5 7 5 11 5 13 0 Noise level Low Middle High dB 24 26 28 25 28 31 25 30 34 27 34 39 32 40 43 Net weight kg 15 3 9 Specifications Notes 1 This figure indicates GRILLE s 2 Specifications subject to change without ...

Page 19: ...dicionadores de aire y bombas de calor descritas a continuación para su uso en entornos residenciales comerciales y de industria ligera conferma con la presente sotto la sua esclusiva responsabilità che i condizionatori d aria e le pompe di calore descritti di seguito e destinati all utilizzo in ambienti residenziali commerciali e semi industriali με το παρόν πιστοποιεί με αποκλειστική της ευθύνη ...

Page 20: ... demás idiomas son traducciones del original CUIDADO Las pérdidas de refrigerante pueden causar asfixia Se debe proporcionar la ventilación de terminada en EN378 1 Asegúrese de colocar el aislante alrededor de las tuberías El contacto directo con la tubería puede ocasionar quemaduras o congelación Para evitar una ingestión accidental no coloque las pilas en su boca bajo ningún concepto La ingestió...

Page 21: ...tijekom rada ili pojavu vibracija Mjerenje zvuka obavljeno je sukladno normama JIS C9612 JIS B8616 ISO 5151 T1 i ISO 13523 T1 A hűtőközeg szivárgása fulladást okozhat Gondoskodjon az EN378 1 szabvány előírásai szerinti szellőzésről Feltétlenül szigetelje körbe a csöveket A csupasz cső megérintése égési vagy fagyási sérül ést okozhat Ne vegyen a szájába elemet semmilyen célból mert véletlenül lenye...

Page 22: ... 1 Viale Colleoni 7 20864 Agrate Brianza MB Italy Norwegian Branch Gneisveien 2D 1914 Ytre Enebakk Norway Portuguese Branch Avda do Forte 10 2799 514 Carnaxide Lisbon Portugal Spanish Branch Carretera de Rubi 76 80 Apdo 420 08173 Sant Cugat del Valles Barcelona Spain Scandinavian Branch Hammarbacken 14 P O Box 750 SE 19127 Sollentuna Sweden UK Branch Travellers Lane Hatfield Herts AL10 8XB England...