80
1
ON
2 3 4 5 6
degF
Discharge superheat. SHd
0~327
Cooling = TH4 (or TH32)-TH6
Heating = TH4 (or TH32)-TH5
0~327 (0~182degC)
(When the temperature is 100degF or more, hun-
dreds digit, tens digit and ones digit are displayed
by turns.)
degF
Sub cool. SC
0~234
Cooling = TH6-TH3
Heating = TH5-TH2
0~234 (0~130degC)
(When the temperature is 100degF or more, hun-
dreds digit, tens digit and ones digit are displayed
by turns.)
0.1 A
Input current of outdoor unit
0~500
(When it is 100 or more, hundreds digit, tens digit
and ones digit are displayed by turns.)
Hz
Targeted operation frequency
0~255
0~255
(When it is 100Hz or more, hundreds digit, tens
digit and ones digit are displayed by turns.)
DC bus voltage
180~370
180~370
(When it is 100V or more, hundreds digit, tens
digit and ones digit are displayed by turns.)
V
1
ON
2 3 4 5 6
1
ON
2 3 4 5 6
1
ON
2 3 4 5 6
1
ON
2 3 4 5 6
SW2 setting
1
ON
2 3 4 5 6
Display detail
Explanation for display
Unit
˚
F
1
ON
2 3 4 5 6
1
ON
2 3 4 5 6
1
ON
2 3 4 5 6
Indoor setting temperature
62~86
Outdoor pipe temperature / 2-phase
pipe (TH6)
-38~190
Outdoor heatsink temperature (TH8)
-40~327
62~86 (17~30
:
)
˚
F
˚
F
˚
F
-38~190 (-39~88
:
)
(When the temperature is 0
˚
F or less, “–” and
temperature are displayed by turns.)
-40~327 (-40~164
:
)
(When the temperature is 0
˚
F or less, “–” and
temperature are displayed by turns.)
(When the thermistor detects 100
˚
F or more,
hundreds digit, tens digit and ones digit are
displayed by turns.)
Outdoor outside temperature (TH7)
-38~190
-38~190 (-39~88
:
)
(When the temperature is 0
˚
F or less, “–” and
temperature are displayed by turns.)
The black square (
■