OUTLINES AND DIMENSIONS
PUHZ-ZRP35VKA
PUHZ-ZRP50VKA
Unit : mm
Free space around the outdoor unit (basic example)
100mm or more as long as
no obstacle is placed on the
rear and right-and-left sides
of the unit
2 sides should be open in
the right, left and rear side.
Please secure the unit firmly
with 4 foundation (M10) bolts.
(Bolts, washers and nut must
be purchased locally).
FOUNDA
TION BOL
TS
Piping and wiring connection can
be made from the rear direction only
.
PIPING-WIRING DIRECTION
500mm or more
100mm or more
100mm or more
Basically open
350mm or more
Service port
Connection for gas pipe FLARE
:
12.7 (1/2F)
Connection for liquid pipe FLARE
:
6.35 (1/4F)
Service panel
for charge plug
Service panel
Earth terminal
( )
Terminal connection Left
Power supply wiring
Right
Indoor/Outdoor wiring
23.2
99.5
164.5
492
193.5
35°
43°
Air discharge
Air intake
Air intake
oval hole
4-10×21
drain hole
:
42
360
330
32.5
300
40
404.5
48
Handle for moving
Installation bolt pitch
22.3
630
320
8.5
809
500
310
154.5
62
FOUNDA
TION
18
<Foundation bolt height>
Less than
OCH527B