16
4. STANDARD OPERATION DATA
Models
Item
Electrical circuit
Refrigerant circuit
Indoor side
Outdoor side
Voltage
Frequency
Total input
Indoor fan current
Booster heater current
Outdoor fan current
Comp. current
Condensing pressure
Suction pressure
Discharge temperature
Condensing temperature
Suction temperature
Comp.shell bottom temperature
Ref. pipe length
Refrigerant charge
Fan speed
Airflow (High)
Fan speed upper/lower
Airflow
Unit
V
Hz
kW
A
A
A
A
psi.G
psi.G
˚F
˚F
˚F
˚F
ft
˚F
˚F
˚F
˚F
r.p.m.
CFM
˚F
˚F
r.p.m.
CFM
Btu/h
208/230
1.79
0.5
0.75
7.4/6.9
255
81
182
118
66
171
80
67
61
59
95
75
18,000
0.82
60
Cooling
208/230
1.56
0.5
7.6/8.4
0.75
6.1/5.9
202
61
126
102
34
111
70
60
96
68
47
43
18,600
Heating
PKH18FK3
208/230
2.36
0.5
0.65+0.65
9.3/8.7
240
75
158
115
46
141
80
67
58
56
95
75
24,000
0.71
60
Cooling
208/230
2.37
0.5
7.6/8.4
0.65+0.65
9.5/8.7
243
63
149
115
35
126
70
60
105
70
47
43
25,000
Heating
PKH24FK3
208/230
3.12
0.6
0.75+0.75
12.6/11.8
245
80
158
115
49
138
80
67
59
58
95
75
30,000
0.75
60
Cooling
208/230
3.02
0.6
8.7/9.6
0.75+0.75
12.2/11.4
236
60
159
113
32
130
70
60
103
70
47
43
33,000
Heating
PKH30FK3
208/230
3.44
0.6
0.75+0.75
14.3/13.2
243
74
160
115
45
142
80
67
58
56
95
75
34,200
0.71
60
25
5 lbs 8 oz
1,310
710
1,310
710
1,400
990
1,400
990
790
1,590
750/750
3,170
760/760
3,350
760/760
3,350
25
9 lbs 15 oz
25
10 lbs 2 oz
25
10 lbs 9 oz
Cooling
208/230
3.54
0.6
8.7/9.6
0.75+0.75
14.7/13.7
263
60
170
120
33
148
70
60
109
71
47
43
38,000
Heating
PKH36FK3
Intake
air temperature
Discharge
air temperature
Intake
air temperature
Capacity
SHF
DB
WB
DB
WB
DB
WB
OC273-A-1.qxp 03.11.25 8:59 AM Page 16