9
Model name
Indoor unit
PEAD-RP71GA
PEAD-RP100GA
Outdoor unit
PUH-P71VHA
PUH-P71YHA PUH-P100VHA PUH-P100YHA
Cooling
Capacity
Btu/h
27,000
33,100
kW
7.9
9.7
Total input
kW
2.97
3.98
EER
2.66
2.44
Energy label class
D
E
SHF
0.83
0.86
Heating
Capacity
Btu/h
30,700
39,200
kW
9.0
11.5
Total input
kW
3.11
4.09
COP
2.89
2.81
Energy label class
D
D
Booster heater
kW
-
-
Power supply
Phase
[
1
3
1
3
Cycle
Hz
50
50
50
50
Voltage
V
230
400
230
400
Breaker size
A
32
16
32
16
Indoor unit
Air flow
CMM
20-25
26.5-33
(Low-High)
CFM
706-883
935-1165
External pressure
Pa
10/50/70
10/50/70
Sound level
dB(A)
35-38/37-41/37-43
40-43/42-45/42-46
(Low-High)
(10/50/70Pa)
(10/50/70Pa)
External finish
Galvanized sheets
Dimension
W : mm
1171
1411
D : mm
740
H : mm
275
W : inch
46-1/8
55-9/16
D : inch
29-1/8
H : inch
10-13/16
Weight
kg
42
50
lbs
93
111
Unit drain pipe O.D.
mm
32
inch
1-1/4
Outdoor unit
Air flow
CMM
55
65
CFM
1,940
2,290
Sound level at cooling
dB(A)
49
50
Sound level at heating
dB(A)
50
52
External finish
Ivory Munsell 5Y 7/1
Dimension
W : mm
950
950
D : mm
330+30
330+30
H : mm
943
943
W : inch
37-3/8
37-3/8
D : inch
13 + 1-3/16
13 + 1-3/16
H : inch
37-1/8
37-1/8
Weight
kg
93
94
lbs
205
207
Refrigerant pipe size
Gas side O.D.
mm
15.88
15.88
inch
5/8
5/8
Liquid side O.D.
mm
9.52
9.52
inch
3/8
3/8
Refrigerant pipe length Height difference
m
Max. 50
Max. 50
Length
m
Max. 50
Max. 50
NOTE:
1. Rating conditions (ISO T1)
Cooling Indoor : D.B. 27
:
(80˚F) W.B. 19
:
(66˚F)
Outdoor : D.B. 35
:
(95˚F) W.B. 24
:
(75˚F)
Heating Indoor : D.B. 20
:
(68˚F)
Outdoor : D.B. 7
:
(45˚F) W.B. 6
:
(43˚F)
Refrigerant piping length (one way) : 5m (16ft.)
2. Guaranteed operating range
Indoor
Outdoor
Cooling
Upper limit D.B. 35˚C, W.B. 22.5˚C D.B. 46
:
Lower limit D.B. 19˚C, W.B. 15˚C
D.B. -5
:
w
Heating
Upper limit D.B. 28˚C
D.B. 21
:
, W.B. 15˚C
Lower limit D.B. 17˚C
D.B. -11
:
, W.B. -12˚C
4. Above data are based on the indicated voltage
w
If optional Air protect guide installed. D.B.-15
:
Indoor unit
Single phase 230V 50Hz
Single phase 230V 50Hz
/ 3 phase 400V 50Hz
Outdoor unit
3. Guaranteed voltage
198~264V, 50Hz : Single phase
342~457V, 50Hz : 3 phase
OCS07B-1.qxp 07.4.10 0:44 PM Page 9
Summary of Contents for Mr.SLIM PKA-RP FAL2
Page 37: ...37 WIRED REMOTE CONTROLLER Unit mm 130 120 19 ...
Page 38: ...38 WIRELESS REMOTE CONTROLLER Unit mm 159 3 55 58 19 ...
Page 66: ...66 9 3 PLA RP AA PLA RP AA2 9 3 1 FRESH AIR INTAKE AMOUNT ...
Page 67: ...67 9 3 2 BRANCH DUCT Installation at site ...
Page 77: ...77 PEAD RP60GA PEAD RP71GA ...
Page 78: ...78 PEAD RP100GA ...
Page 85: ...85 ...