43
PEAD-RP35EA2
PEAD-RP50EA
PEAD-RP60EA
PEAD-RP71EA
PEAD-RP100EA2 PEAD-RP125EA
PEAD-RP140EA
<
w
A>
N
L
S1
S2
1 2
2
1
1 2
S3
TO CND
TO OUTDOOR
UNIT
TO CN3C
ON
OFF
1 2 3 4 5
ON
OFF
1 2 3 4 5
ON
OFF
1 2 3 4 5
ON
OFF
1 2 3 4 5
ON
OFF
1 2 3 4 5
ON
OFF
1 2 3 4 5
ON
OFF
1 2 3 4 5
5
4
3
2
1
OFF
ON
50EA
60EA
71EA
35EA(
2
)
100EA(
2
)
125EA
140EA
Capacity cord
switch
Model selection
switch
SW2
SW1
MODELS
POWER SUPPLY
~(1PHASE)
230V 50Hz
(IN CASE OF CONNECT
THE REPLACEMENT WIRING)
TO OUTDOOR UNIT
TO MA-REMOTE
CONTROLLER
DC8.7-13V
I.B.
X6
X4
X5
X1
ZNR
FUSE
P.B.
CN31
1
3
DS
INSIDE SECTION OF CONTROL BOX
B
L
U
B
L
U
B
L
U B
L
U
TB5
(RED)
6
4
3
5
2
1
C
MF
X6
X5
X4
X1
(RED)
CNDK
(BLU)
CNP
(WHT)
FAN
1
Y
L
W
O
R
N
(ORN)
3
1
CND
2
1
(RED)
LED1
LED2
LED3
CN2L
OFF
ON
SWE
SW2
SW1
(RED)
(WHT)
P
N
K
P
N
K
B
L
K
B
L
K
W
H
T
B
L
K
B
L
K
W
H
T
W
H
T
W
H
T
1
2
3
1
CN2S
CNSK
(WHT)
(RED)
YLW
ORN
BRN
B
R
N
O
R
N
(BLU)
WHT
BLK
CN2D
(WHT)
(BLU)
(RED)
(WHT) (BLK)
(WHT)
(WHT)
(WHT)
(YLW)
(WHT)
(WHT)
w
A
DP
6
4
3
5
2
1
2
1
TB4
S3
S1
S2
2
1
3
3
1
6
4
3
5
2
1
MF
C
1 2
CN24
3
2
1
1 2 3
1 2
1 2
1 2
TH5
TH2
TH1
1
2
CN3C
3
1
1
3
7 5
CN22
CN20
CN21
CN29
CN31
CN90
CN41
CN51
CN32
2
1
1 2 3 4 5 6 7 8 9
4
3
2
1
4 5
3
2
1
<PEAD-RP71•100•125•140EA, 100EA2>
External static
pressure 130Pa
<PEAD-RP71•100•125•140EA, 100EA2>
External static pressure 70Pa
<PEAD-RP35•50•60EA, 35EA2>
External static
pressure 70Pa
Optional parts
Optional parts
<PEAD-RP35•50•60EA, 35EA2>
External static
pressure 30Pa
(OPTIONAL PARTS)
DRAIN PUMP
RELAY(DRAIN PUMP)
X1
CONNECTOR(WIRELESS)
DP
DS
TRANSMISSION(INDOOR•OUTDOOR)
LED3
SWITCH(MODEL SELECTION)
SW1
POWER SUPPLY(REMOTE CONTROLLER)
LED2
LED1 POWER SUPPLY(I.B.)
CN90
CN51 CONNECTOR(CENTRALLY CONTROL)
CN24 CONNECTOR(HEATER)
VARISTOR
FUSE(T6.3AL250V)
ZNR
FUSE
INDOOR POWER BOARD
P.B.
COND./EVA. TEMP. THERMISTOR
(0
:
/15
t
,25
:
/5.4
t
DETECT)
PIPE TEMP. THERMISTOR/LIQUID
(0
:
/15
t
,25
:
/5.4
t
DETECT)
INTAKE AIR TEMP. THERMISTOR
(0
:
/15
t
,25
:
/5.4
t
DETECT)
TERMINAL BLOCK(REMOTE CONTROLLER)
FAN MOTOR
CAPACITOR(FAN MOTOR)
DRAIN SENSOR
DRAIN PUMP
TH5
TH2
TH1
TB5
(INDOOR/OUTDOOR CONNECTING LINE)
TERMINAL BLOCK
TB4
MF
C
NAME
NAME
SYMBOL
SYMBOL
NAME
RELAY(FAN MOTOR)
RELAY(FAN MOTOR)
SWITCH(CAPACITY CORD)
CONNECTOR(HA TERMINAL-A)
CONNECTOR(REMOTE SWITCH)
INDOOR CONTROLLER BOARD
RELAY(FAN MOTOR)
SWITCH(EMERGENCY OPERATION)
CONNECTOR(LOSSNAY)
X6
X5
X4
SWE
SW2
CN41
CN32
CN2L
I.B.
SYMBOL
Notes:
1. SymboIs used in wiring diagram above are, : Connector, : Terminal (block).
2. Indoor and outdoor connecting wires have poIarities, make sure to match terminal
numbers (S1, S2, S3) for correct wirings.
3. Since the outdoor side electric wiring may change, be sure to check the outdoor unit
electric wiring diagram for servicing.
4. This diagram shows the wiring of indoor and outdoor connecting wires (specification
of 230V), adopting superimposed system of power and signal.
w
1: When work to Supply power separately to indoor and outdoor units was applied,
refer to
w
A.
w
2: For power supply system of this unit, refer to the caution label located near this diagram.
OCS07B-2.qxp 07.4.10 0:40 PM Page 43
Summary of Contents for Mr.SLIM PKA-RP FAL2
Page 37: ...37 WIRED REMOTE CONTROLLER Unit mm 130 120 19 ...
Page 38: ...38 WIRELESS REMOTE CONTROLLER Unit mm 159 3 55 58 19 ...
Page 66: ...66 9 3 PLA RP AA PLA RP AA2 9 3 1 FRESH AIR INTAKE AMOUNT ...
Page 67: ...67 9 3 2 BRANCH DUCT Installation at site ...
Page 77: ...77 PEAD RP60GA PEAD RP71GA ...
Page 78: ...78 PEAD RP100GA ...
Page 85: ...85 ...