2-2 Feature of program timer
!
Daily timer function
Daily timer can be set in 30 minutes units for up to 24 hours.
Each unit can be set for unit ON, unit OFF, or setback operation.
@
Setback operation
Set back operation is useful for reducing running costs.
e.g. At a hotel with a 24-hour system
8:00~23:00 Cooling operation with set temperature at 26˚C
23:00~8:00 Setback operation with 2 degrees of setback
As shown in the chart on the right, the set temperature rises 2
degrees automatically during the setback operation. When the
setback operation ends, normal operation will begin.
#
Weekly timer function
Daily timer function can apply to each day of the week.
Note 1. How to connect refrigerant pipes.
Factory supplied optional refrigerant pipings contain refrigerant at the above atmospheric pressures. As long
as the connection takes no more than 5 minutes, no air will enter, and there will be no need for air purging.
Remove the blind caps and make the connections within 5 minutes. After the connecitons for the indoor and
outdoor units are made, open the stop valve on the outdoor unit to allow refrigerant gas to flow.
If piping length exceeds 5m, an additional charge of refrigerant is needed.
Note 2. The following main parts are contained in the optional refrigerant piping kit.
Heat insulating cover, vinyl tapes, nipples, sleeve and flange (for wall hole), connecting cables.
28
˚
C
26
˚
C
8:00
Normal
operation
23:00
Setback
operation
8:00
Normal
operation
2. TIMER
When using a program timer, a program timer adapter (PAC-825AD) is also needed.
Part No.
Model Name
PAC-SC32PTA
Program timer
2-1 Program timer specifications
Parts name
Parts No.
Exterior dimensions(inch)
Installation
Type of clock
Clock accuracy
Display -Time
-Week
-Timer setting
Program cycle
Timer setting unit
No. of set points
Power rating
Program timer
PAC-SC32PTA
5-4/32
o
4-23/32
o
23/32(130
o
120
o
18mm)
Wall mount
Quartz
i
50 second / month at 25
:
Liquid crystal display
Liquid crystal display
Liquid crystal display
24 hours
30 minutes
48 /day
5V DC
i
5%(Supplyed by Remote Controller)
Part No.
PAC-05FFS-E
PAC-07FFS-E
PAC-10FFS-E
PAC-15FFS-E
Pipe length
5m
7m
Pipe size O.D.
Liquid :
{
9.52 Gas :
{
15.88
Connection method
Indoor unit : Flared Outdoor unit : Flared
10m
15m
Part No.
PAC-SC51PI-E
PAC-SC52PI-E
PAC-SC53PI-E
PAC-SC54PI-E
Pipe length
5m
7m
Pipe size O.D.
Liquid :
{
9.52 Gas :
{
19.05
Connection method
Indoor unit : Flared Outdoor unit : Flared
10m
15m