MEANINGS OF SYMBOLS ON THE UNIT

WARNING

(Risk of fire)

This symbol is only for R32 refrigerant. The type of the refrigerant used is written on the nameplate on the outdoor unit.

R32 refrigerant is flammable. If the refrigerant leaks, or comes in contact with fire or parts that generate heat, it may create 

harmful gas and pose a risk of fire.

Read the OPERATION MANUAL carefully before operation.

Service personnel are required to carefully read the OPERATION MANUAL and INSTALLATION MANUAL before operation.

Further information is available in the OPERATION MANUAL, INSTALLATION MANUAL, and the like.

Symbols used in the text

 

Warning:

Describes precautions that should be observed to prevent danger 

of injury or death to the user.

 Caution:

Describes precautions that should be observed to prevent damage 

to the unit.

Symbols used in the illustrations

  : Indicates a part which must be grounded.

 Warning:

•  These appliances are not accessible to the general public. 

•  The unit must not be installed by the user. Ask the dealer or an 

authorized company to install the unit. If the unit is installed 

improperly, water leakage, electric shock or fire may result.

•  Do not stand on, or place any items on the unit. 

•  Do not splash water over the unit and do not touch the unit with 

wet hands. An electric shock may result.

•  Do not spray combustible gas close to the unit. Fire may result.

•  Do not place a gas heater or any other open-flame appliance 

where it will be exposed to the air discharged from the unit. 

Incomplete combustion may result.

•  Do not remove the front panel or the fan guard from the outdoor 

unit when it is running. 

•  When you notice exceptionally abnormal noise or vibration, stop 

operation, turn off the power switch, and contact your dealer.

•  Never insert fingers, sticks etc. into the intakes or outlets.

•  If you detect odd smells, stop using the unit, turn off the power 

switch and consult your dealer. Otherwise, a breakdown, electric 

shock or fire may result.

•  This air conditioner is NOT intended for use by children or infirm 

persons without supervision.

•  Young children must be supervised to ensure that they do not 

play with the air conditioner.

• 

If the refrigeration gas blows out or leaks, stop the operation of the air 

conditioner, thoroughly ventilate the room, and contact your dealer.

1. Safety Precautions .................................................................2

2. Parts Names ...........................................................................3

3. Operation ................................................................................

6

4. Timer.......................................................................................

9

5.   Emergency Operation for Wireless Remote-controller 

 

(option) ...................................................................................

9

6. Care and Cleaning..................................................................

9

7. Trouble Shooting ..................................................................

10

8. Specifications .......................................................................

11

Note:

The phrase “Wired remote controller” in this operation manual refers only to the PAR-33MAA. If you need any information for the other remote controller, 

please refer to the instruction book included with the remote controller.

•  When installing, relocating, or servicing the air conditioner, 

use only the specified refrigerant written on the outdoor unit to 

charge the refrigerant lines. Do not mix the refrigerant with any 

other refrigerant, and do not allow air to remain in the lines.

-  If air is mixed with the refrigerant, then it may cause abnormal high 

pressure in the refrigerant lines, resulting in an explosion and other 

hazards.

-  The use of any refrigerant other than that specified for the 

system will cause mechanical failure, system malfunction, or 

unit breakdown. In the worst case, this could lead to a serious 

impediment to securing product safety.

-  It may also be in violation of applicable laws.

-  MITSUBISHI ELECTRIC CORPORATION cannot be held 

responsible for malfunctions or accidents resulting from the use of 

the wrong type of refrigerant.

•  This indoor unit should be installed in a room which is equal 

to or larger than the floor space specified in the outdoor unit 

installation manual. Refer to the outdoor unit installation manual.

•  Only use means recommended by the manufacturer to accelerate 

the defrosting process or to clean.

•  This indoor unit shall be stored in a room that has no 

continuously-operating ignition device such as open flame, gas 

appliance, or electrical heater.

•  Do not pierce a hole in or burn this indoor unit or refrigerant 

lines.

•  Be aware that the refrigerant may be odour-free.

 Caution:

•  Do not use any sharp object to push the buttons, as this may 

damage the remote controller.

• 

Never block or cover the indoor or outdoor unit’s intakes or outlets.

 

Disposing of the unit

When you need to dispose of the unit, consult your dealer.

Summary of Contents for Mr. SLIM PEAD-M100JAA

Page 1: ...ir Conditioners PEAD M50 60 71 100 125 140JAA D English OPERATION MANUAL For safe and correct use please read this operation manual thoroughly before operating the air conditioner unit FOR USER ORIGINAL ...

Page 2: ...ric shock or fire may result This air conditioner is NOT intended for use by children or infirm persons without supervision Young children must be supervised to ensure that they do not play with the air conditioner If the refrigeration gas blows out or leaks stop the operation of the air conditioner thoroughly ventilate the room and contact your dealer 1 Safety Precautions 2 2 Parts Names 3 3 Oper...

Page 3: ...he screen When the backlight is off pressing any button turns the backlight on and does not perform its function except for the ON OFF button ON OFF lamp This lamp lights up in green while the unit is in operation It blinks while the remote controller is starting up or when there is an error Function button F1 Main display Press to change the operation mode Main menu Press to move the cursor down ...

Page 4: ...hen the buttons are locked Full mode All icons are displayed for explanation Basic mode Fri Mode Temp Fan Room Cool Set temp Fri Cool Mode Temp Fan Set temp Appears when the On Off timer Night setback or Auto off timer function is enabled appears when the timer is disabled by the centralized control system Appears when the Weekly timer is enabled Appears while the units are operated in the energy ...

Page 5: ...acing the remote controller install the holder included with the remote controller on a wall and be sure to always place the remote controller in the holder after use Battery installation replacement 1 Remove the top cover insert two AAA batteries and then install the top cover Top cover Two AAA batteries Insert the negative end of each battery first Install the batteries in the correct directions...

Page 6: ...peration modes in the order of Cool Dry Fan Auto and Heat Select the desired operation mode Cool Dry Fan Auto Heat Operation modes that are not available to the connected indoor unit models will not appear on the display What the blinking mode icon means The mode icon will blink when other indoor units in the same refrigerant system connected to the same outdoor unit are already operated in a diff...

Page 7: ...tate in flashing In this case please set all the indoor units to the same operation mode There might be a case that the indoor unit which is operating in AUTO mode Cannot change over to the operating mode COOL HEAT and becomes a state of standby When indoor unit starts the operation while the defrosting of outdoor unit is being done it takes a few minutes max about 15 minutes to blow out the warm ...

Page 8: ...display If no buttons are touched for 10 minutes the screen will automatically return to the Main display Any settings that have not been saved will be lost Display of unsupported functions F1 F2 F3 F4 Title Not available Unsupported function Return The message at left will appear if the user selects a function not supported by the corresponding indoor unit model 3 5 2 Vane Vent Lossnay Accessing ...

Page 9: ...ows Press the AUTOSTOP button Time can be set while the following symbol is blinking Off time Ⓒ STOP is blinking The stop times is displayed at Ⓓ Use the h and min buttons to set the desired time To cancel the OFF timer press the AUTOSTOP button 4 Changing the set times Press the AUTOSTART or AUTOSTOP to cancel the timer and repeat from 2 or 3 Cleaning the filters Clean the filters using a vacuum ...

Page 10: ...e water on the heat exchanger evaporates and water vapor may be emitted appears in the remote controller display During central control appears in the remote controller display and air conditioner operation cannot be started or stopped using the remote controller When restarting the air conditioner soon after stopping it it does not operate even though the ON OFF button is pressed Wait approximate...

Page 11: ...itch the auto mode setting to the AUTO single set point mode or AUTO dual set point mode For details refer to the included Notice A5 sheet or the Installation Manual 8 Specifications Item Model PEAD M50JAA D PEAD M60JAA D PEAD M71JAA D PEAD M100JAA D Power source 220 240 V 50 60 Hz Dimension Height mm 250 Width mm 900 1100 1400 Depth mm 732 Net weight 2 kg 26 27 29 30 38 39 Fan Airflow rate Low Mi...

Page 12: ...Please be sure to put the contact address telephone number on this manual before handing it to the customer HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN VN79D606H03 ...

Reviews: