background image

10

7. Trouble Shooting

Having trouble?

Here is the solution. (Unit is operating normally.)

Air conditioner does not heat or cool well.

 

Clean the filter. (Airflow is reduced when the filter is dirty or clogged.)

 

Check the temperature adjustment and adjust the set temperature.

 

Make sure that there is plenty of space around the outdoor unit. Is the 

indoor unit air intake or outlet blocked?

 

Has a door or window been left open?

When heating operation starts, warm air does not blow from the indoor 

unit soon.

 

Warm air does not blow until the indoor unit has sufficiently warmed up.

During heating mode, the air conditioner stops before the set room 

temperature is reached.

 

When the outdoor temperature is low and the humidity is high, 

frost may form on the outdoor unit. If this occurs, the outdoor unit 

performs a defrosting operation. Normal operation should begin after 

approximately 10 minutes.

A flowing water sound or occasional hissing sound is heard.

 

These sounds can be heard when refrigerant is flowing in the air 

conditioner or when the refrigerant flow is changing.

A cracking or creaking sound is heard.

 

These sounds can be heard when parts rub against each due to 

expansion and contraction from temperature changes.

The room has an unpleasant odor.

 

The indoor unit draws in air that contains gases produced from the 

walls, carpeting, and furniture as well as odors trapped in clothing, and 

then blows this air back into the room.

A white mist or vapor is emitted from the indoor unit.

 

If the indoor temperature and the humidity are high, this condition may 

occur when operation starts.

 

During defrosting mode, cool airflow may blow down and appear like a 

mist.

Water or vapor is emitted from the outdoor unit.

 

During cooling mode, water may form and drip from the cool pipes and 

joints.

 

During heating mode, water may form and drip from the heat exchanger.

 

During defrosting mode, water on the heat exchanger evaporates and 

water vapor may be emitted.

” appears in the remote controller display.

 

During central control, “

” appears in the remote controller display 

and air conditioner operation cannot be started or stopped using the 
remote controller.

When restarting the air conditioner soon after stopping it, it does not 

operate even though the ON/OFF button is pressed.

 

Wait approximately three minutes.

 

 (Operation has stopped to protect the air conditioner.)

Air conditioner operates without the ON/OFF button being pressed.

 

Is the on timer set?

 

Press the ON/OFF button to stop operation.

 

Is the air conditioner connected to a central remote controller?

 

Consult the concerned people who control the air conditioner.

 

Does “

” appear in the remote controller display?

 

Consult the concerned people who control the air conditioner.

 

Has the auto recovery feature from power failures been set?

 

Press the ON/OFF button to stop operation.

Air conditioner stops without the ON/OFF button being pressed.

 

Is the off timer set?

 

Press the ON/OFF button to restart operation.

 

Is the air conditioner connected to a central remote controller?

 

Consult the concerned people who control the air conditioner.

 

Does “

” appear in the remote controller display?

 

Consult the concerned people who control the air conditioner.

Remote controller timer operation cannot be set.

 

Are timer settings invalid?

 

If the timer can be set, 

 or 

 appears in the remote controller 

display.

“PLEASE WAIT” appears in the remote controller display.

 

The initial settings are being performed. Wait approximately 3 minutes.

An error code appears in the remote controller display.

 

The protection devices have operated to protect the air conditioner.

 

Do not attempt to repair this equipment by yourself.

 

Turn off the power switch immediately and consult your dealer. Be 

sure to provide the dealer with the model name and information that 

appeared in the remote controller display.

Draining water or motor rotation sound is heard.

 

When cooling operation stops, the drain pump operates and then 

stops. Wait approximately 3 minutes.

Summary of Contents for Mr. SLIM PEAD-M100JAA

Page 1: ...ir Conditioners PEAD M50 60 71 100 125 140JAA D English OPERATION MANUAL For safe and correct use please read this operation manual thoroughly before operating the air conditioner unit FOR USER ORIGINAL ...

Page 2: ...ric shock or fire may result This air conditioner is NOT intended for use by children or infirm persons without supervision Young children must be supervised to ensure that they do not play with the air conditioner If the refrigeration gas blows out or leaks stop the operation of the air conditioner thoroughly ventilate the room and contact your dealer 1 Safety Precautions 2 2 Parts Names 3 3 Oper...

Page 3: ...he screen When the backlight is off pressing any button turns the backlight on and does not perform its function except for the ON OFF button ON OFF lamp This lamp lights up in green while the unit is in operation It blinks while the remote controller is starting up or when there is an error Function button F1 Main display Press to change the operation mode Main menu Press to move the cursor down ...

Page 4: ...hen the buttons are locked Full mode All icons are displayed for explanation Basic mode Fri Mode Temp Fan Room Cool Set temp Fri Cool Mode Temp Fan Set temp Appears when the On Off timer Night setback or Auto off timer function is enabled appears when the timer is disabled by the centralized control system Appears when the Weekly timer is enabled Appears while the units are operated in the energy ...

Page 5: ...acing the remote controller install the holder included with the remote controller on a wall and be sure to always place the remote controller in the holder after use Battery installation replacement 1 Remove the top cover insert two AAA batteries and then install the top cover Top cover Two AAA batteries Insert the negative end of each battery first Install the batteries in the correct directions...

Page 6: ...peration modes in the order of Cool Dry Fan Auto and Heat Select the desired operation mode Cool Dry Fan Auto Heat Operation modes that are not available to the connected indoor unit models will not appear on the display What the blinking mode icon means The mode icon will blink when other indoor units in the same refrigerant system connected to the same outdoor unit are already operated in a diff...

Page 7: ...tate in flashing In this case please set all the indoor units to the same operation mode There might be a case that the indoor unit which is operating in AUTO mode Cannot change over to the operating mode COOL HEAT and becomes a state of standby When indoor unit starts the operation while the defrosting of outdoor unit is being done it takes a few minutes max about 15 minutes to blow out the warm ...

Page 8: ...display If no buttons are touched for 10 minutes the screen will automatically return to the Main display Any settings that have not been saved will be lost Display of unsupported functions F1 F2 F3 F4 Title Not available Unsupported function Return The message at left will appear if the user selects a function not supported by the corresponding indoor unit model 3 5 2 Vane Vent Lossnay Accessing ...

Page 9: ...ows Press the AUTOSTOP button Time can be set while the following symbol is blinking Off time Ⓒ STOP is blinking The stop times is displayed at Ⓓ Use the h and min buttons to set the desired time To cancel the OFF timer press the AUTOSTOP button 4 Changing the set times Press the AUTOSTART or AUTOSTOP to cancel the timer and repeat from 2 or 3 Cleaning the filters Clean the filters using a vacuum ...

Page 10: ...e water on the heat exchanger evaporates and water vapor may be emitted appears in the remote controller display During central control appears in the remote controller display and air conditioner operation cannot be started or stopped using the remote controller When restarting the air conditioner soon after stopping it it does not operate even though the ON OFF button is pressed Wait approximate...

Page 11: ...itch the auto mode setting to the AUTO single set point mode or AUTO dual set point mode For details refer to the included Notice A5 sheet or the Installation Manual 8 Specifications Item Model PEAD M50JAA D PEAD M60JAA D PEAD M71JAA D PEAD M100JAA D Power source 220 240 V 50 60 Hz Dimension Height mm 250 Width mm 900 1100 1400 Depth mm 732 Net weight 2 kg 26 27 29 30 38 39 Fan Airflow rate Low Mi...

Page 12: ...Please be sure to put the contact address telephone number on this manual before handing it to the customer HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN VN79D606H03 ...