8
. Electrical work
Fig. -
Mode number
Setting number
Refrigerant address
Unit number
Function table
Select unit number 00
Mode
Settings
Mode no.
Setting no.
Initial setting
Setting
Power failure automatic recovery
Not available
01
1
Available *1
2
Indoor temperature detecting
Main indoor unit
02
1
Main indoor unit
2
Remote controller’s internal sensor
3
LOSSNAY connectivity
Not Supported
03
1
Supported (indoor unit is not equipped with outdoor-air intake)
2
Supported (indoor unit is equipped with outdoor-air intake)
3
Power voltage
240 V
04
1
220 V, 230 V
2
Select unit numbers 01 to 03 or all units (AL [wired remote controller]/07 [wireless remote controller])
Mode
Settings
Mode no.
Setting no.
Initial setting
Setting
Filter sign
100 Hr
07
1
2500 Hr
2
No filter sign indicator
3
*1 When the power supply returns, the air conditioner will start 3 minutes later.
Fig. 6-8
1
Outdoor unit
2
Indoor unit
3
Interface (MAC-397IF-E)
4
MA remote controller
5
Connect terminal of MA
remote controller each
other.
.. System control
For a group control with MA remote controller (PAR-21MAA), the optional kit (MAC-
397IF-E) is necessary.
Note:
1. Be sure the Auto Heating/Cooling Display Setting on the MA remote con-
troller (PAR-21MAA) is set to OFF before use.
• For information on how to set the Auto Heating/Cooling Display Setting,
see 8. Function Selection on the operation manual.
• The actual operating status of the unit may differ from what is shown on
the remote controller display.
. A test run cannot be initiated using the test run switch on the MA remote
controller (PAR-1MAA).
3. The horizontal vanes on the unit cannot be operated using louver switch
of the MA remote controller (PAR-1MAA).
4. The range of room temperature indication is between 10 °C and 38 °C.
5. Set the dip switches (SW500, 501, 502) on the interface unit before turning
the power ON.
. The air conditioner will not operate properly unless the dip switches
(SW500, 501, 502) on the interface unit are properly set.
. The contents that appear on the displays may differ between the MA re-
mote controller that is connected to the indoor unit and the MA remote
controller that is connected to the interface unit.
8.
Function setting (Selecting the unit function) and test run cannot be performed
from the MA remote controller when connecting it to the Interface (MAC-39IF-E).
One remote controller can be used to operate multiple unit (Fig. 6-9)
This function of group control allows to operate multiple units (a maxi
-
mum of up to 1 outdoor units) as one group with one remote controller.
Connect interface (MAC-397IF-E) to the connecter (CN105/CN92) of the
indoor controller board (ever refrigerant address) (Fig. 6-8)
Connect the MA remote controller to the terminal A/B of the refrigerant ad-
dress “0” interface (MAC-397IF-E). (Fig. 6-9)
Connect every refrigerant address of interface (MAC-39IF-E) each other’s
terminal A/B.
A
: Refrigerant address “0”
B
: Refrigerant address “1”
C
: Refrigerant address “2”
.4. Function settings
.4.1. Function setting on the unit (Fig. -)
Changing the power voltage setting
• Be sure to change the power voltage setting depending on the voltage used.
1
Go to the function setting mode.
Switch OFF the remote controller.
Press the
A
and
B
buttons simultaneously and hold them for at least 2
seconds. FUNCTION will start to blink.
2
Use the
C
button to set the refrigerant address ( ) to 00.
3
Press
D
and [--] will start to blink in the unit number ( ) display.
4
Use the
C
button to set the unit number ( ) to 00.
5
Press the
E
MODE button to designate the refrigerant address/unit number. [--]
will blink in the mode number ( ) display momentarily.
6
Press the
F
buttons to set the mode number ( ) to 04.
7
Press the
G
button and the current set setting number ( ) will blink.
Use the
F
button to switch the setting number in response to the power supply
voltage to be used.
Power supply voltage
240 V
: setting number = 1
220 V, 230 V : setting number = 2
8
Press the MODE button
E
and mode and the setting number ( ) and ( ) will
change to being on constantly and the contents of the setting can be confirmed.
9
Press the FILTER
A
and TEST RUN
B
buttons simultaneously for at least two
seconds. The function selection screen will disappear momentarily and the air
conditioner OFF display will appear.
.4.. Function setting on the remote controller
Refer to the indoor unit operation manual.
1
PAC indoor unit
2
Interface unit (MAC-397IF-E)
3
Remote controller cord that came with
the MA remote controller
4
MA remote controller (PAR-21MAA)
* PAR-20MAA cannot be used with this interface.
Fig. -9
BG79U935H02.indd 8
2006/12/20 9:32:00