18
6
5
2
1
1
8
1 2
1
8
1
8
4
3
TH1
OFF/ON
OFF/ON
OFF/ON
OFF/ON
TB61
TH2
6
5
2
1
4
3
+
TB62
Adjustable resistor
4-20mA/1-5V/0-10V
Wired Remote Controller
(For Maintenance)
6
5
2
1
4
3
8
7
10
9
11
13
12
14
6
5
2
1
4
3
8
7
10
9
11
13
12
14
TB142
TB141
(External Output)
(External Input)
L
N
S1
S2
S3
L
N
S1
S2
S3
TB6
DC31
1~
339V
FUSE
SW6
LED1
RECTIFICA
TION
LED2
LED3
LED4
LED5
CNS2
(RED)
Interface controller
TO OUTDOOR UNIT
U
U
DSA
2
1
SYMBOL
INTERF
ACE CONTROLLER
TB6
TB141
TB142
TB62
TB61
LED1
LED2~5
FUSE
SW1
SW2
SW3
SW6
ZNR01,02
DSA
X1
~
X6
TH1
TH2
TH5
NAME
TERMINAL
BLOCK(INTERF
ACE/OUTDOOR CONNECTING LINE)
TERMINAL
BLOCK (External Output)
TERMINAL
BLOCK (External Input REMOTE SWITCH)
TERMINAL
BLOCK (External Input)
THERMIST
OR(T
ARGET
, PIPE)
POWER SUPPL
Y(I/F)
OPERA
TION INDICA
TION
FUSE(T3.15AL250V)
SWITCH(Input selection of inverter capacity setting) *See table 4.
SWITCH(Function switch)*See table 5 and 6.
SWITCH(LED2~5 Display setting)
SWITCH(4-20mA/1-5V/0-10V switch)*See table 4.
V
ARIST
OR
SURGE ABSORBER
RELA
Y
TARGET
TEMP
. THERMIST
OR
(0
/15k
Ω
, 25
/5.2k
Ω
DETECT)
PIPE TEMP
. THERMIST
OR/LIQUID
(0
/15k
Ω
, 25
/5.2k
Ω
DETECT)
PIPE TEMP
. THERMIST
OR/2-PHASE
(0
/15k
Ω
, 25
/5.2k
Ω
DETECT)
TB6
TO OUTDOOR UNIT
POWER SUPPL
Y
~/N
2
13
5
46
7
8
TB141
11
10
9
12
13
14
ZNR01
ZNR02
2
135
46
7
8
TB142
I/F
9
X1
X2
X3
X4
X5
X6
Item
Operation Output
Error Output
Comp. Output
Defrost Output
Mode(Cool) Output
Mode(Heat) Output
(OUT1)
(OUT2)
(OUT3)
(OUT4)
(OUT5)
(OUT6)
(OUT7)
X1
X2
X3
X4
X5
X6
ON
Error
ON
ON
ON
ON
OFF
Normal
OFF(Comp. OFF)
OFF
OFF
OFF
(Comp. ON)
(Defrosting)
(Cooling)
(Heating)
TB141
1-2
3-4
5-6
7-8
9-10
11-12
13-14
Refer to table 1.
table 1
*1(Fig.1)
Refer to table 2, 3.
Remark
SW2-1, SW2-2: ON is valid.
ON
Forced Comp. OFF
Heating
OFF
Normal
Cooling
Item
Forced Comp. OFF
Fixed operation mode
TB142
1-2 (IN1)
3-4 (IN2)
table 2
Step for capacity setting
TB142
10-1
1
(COM-IN5)
TB142
10-12
(COM-IN6)
TB142
10-13
(COM-IN7)
TB142
10-14
(COM-IN8)
Remark
Auto mode
OFF
Fixed capacity
(Hz fixed)
mode
table 3
TB142
I/F
11
10
12
13
14
11
10
12
13
14
At site
4bit8 switch
OFF
~
AUT
O
TB142
I/F
At site
Step1
Step4
Step7
AUT
O
SW1-1
OFF
ON
ON
ON
OFF
ON
OFF
SW2-3
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF 0%
Step1 10%
Step2 20%
Step3 30%
Step4 50%
Step5 70%
Step6 80%
Step7 100%
Auto
OFF 0%
Step1 10%
Step4 50%
Step7 100%
Auto
[OFF]
[ON]
[OFF]
[ON]
SW2-4
OFF
OFF
ON
ON
OFF
OFF
ON
ON
SW2-5
OFF
OFF
OFF
OFF
ON
ON
ON
ON
Details
Not fixed (Remote controller setting)
Cooling 19
˚
C/Heating 17
˚
C FIX
20
˚
C FIX
22
˚
C FIX
24
˚
C FIX
26
˚
C FIX
28
˚
C FIX
Cooling 30
˚
C / Heating 28
˚
C FIX
SW1-2
OFF
OFF
ON
ON
OFF
OFF
ON
SW2-1
OFF
ON
OFF
ON
SW2-2
OFF
OFF
ON
ON
SW1-3
OFF
OFF
OFF
OFF
ON
ON
ON
SW6-1
OFF
OFF
ON
OFF
OFF
OFF
OFF
SW6-2
OFF
OFF
ON
ON
OFF
OFF
OFF
Input
TypeA
(4bit-8 setting)
TypeB
(1bit-1 setting)
4-20mA
1-5V
0-10V
0-10k
Ω
No input(Auto mode)
Step for capacity setting
OFF/Step 1/Step 2/
...
/Step 7/Auto
OFF/Step 1/Step 4/Step 7/Auto
OFF/Step 1/Step 2/
...
/Step 7
OFF/Step 1/Step 2/
...
/Step 7
OFF/Step 1/Step 2/
...
/Step 7
OFF/Step 1/Step 2/
...
/Step 7/Auto
Only Auto
mode
table 4 SW1, SW6 : Input selection of inverter capacity setting
table 5 SW2-1/2-2 : Fixed operation mode
Details
Not FIX
(Depending on Remote controller setting)
[Cooling]
FIX
[Heating]
FIX
External input(
Depending on
TB142-3,4)
1. SymboIs used in wiring diagram are,
: Connector
,
: T
erminal block.
2. Interface controller and outdoor connecting wires have poIarities, make sure to match
terminal numbers(S1, S2, S3) for correct wirings.
3. Since the outdoor side electric wiring may change, be sure to check the outdoor unit
electric wiring diagram for servicing.
4.
This diagram shows the wiring of Interface controller and outdoor connecting wires.(specification of 230V),
adopting superimposed system of power and signal.
*1 : When work to supply power separately to Interface controller and outdoor units was applied, refer to Fig 1.
*2 : Remove the short-circuited connector CNS2 when work to supply power separately to
Interface controller and outdoor units was applied.
ON
OFF
TypeA
TypeB
At site
*2 Remove the
short-circuited connector CNS2.
table 6 SW2-3/2-4/2-5 : Fixed set temperature [For
Auto mode]
t°
t°
SW3
SW2
SW1
11
10
12
13
14
{
{
{
{
SW2-6
OFF
ON
table 7 SW2-6 : setting
TH5
Details
Connect TH5
Not connect
TH5 (Initial setting)
TH5
t°
(
(
(
3-4. Wiring diagram
(1) PAC-IF011B-E(I/F)
Summary of Contents for Mr.SERVICE PUHZ-HRP100VHA2