3 - 33
3. SIGNALS AND WIRING
(3) Alarm occurrence
Servo motor speed
ON
OFF
Base circuit
Electromagnetic
brake interlock (MBR)
Invalid(ON)
Valid(OFF)
Alarm
No
Yes
Dynamic brake
Dynamic brake
Electromagnetic brake
Electromagnetic brake
operation delay time
Electromagnetic brake
(10ms)
(4) Both main and control circuit power supplies off
Servo motor speed
ON
OFF
Base circuit
Electromagnetic
brake interlock(MBR)
Invalid(ON)
Valid(OFF)
Alarm
No
Yes
ON
OFF
Main circuit
Dynamic brake
Dynamic brake
Electromagnetic brake
Electromagnetic brake
Control circuit
power
(Note)
15 to 100ms
(10ms)
Electromagnetic brake
operation delay time
(Note 2)
Note: Changes with the operating status.
(5) Only main circuit power supply off (control circuit power supply remains on)
Servo motor speed
ON
OFF
Base circuit
Electromagnetic
brake interlock
(MBR)
Invalid(ON)
Valid(OFF)
Alarm
No
Yes
ON
OFF
Main circuit power
supply
Dynamic brake
Dynamic brake
Electromagnetic brake
Electromagnetic brake
(Note 1)
15ms or more
Electromagnetic brake
operation delay time
(Note 2)
(10ms)
Note: 1. Changes with the operating status.
2. When the main circuit power supply is off in a motor stop status, the main circuit off warning (E9)
occurs and the alarm (ALM) does not turn off.
Summary of Contents for MR-J3-B
Page 13: ...A 12 MEMO ...
Page 41: ...2 6 2 INSTALLATION MEMO ...
Page 141: ...7 16 7 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 215: ...11 52 11 OPTIONS AND AUXILIARY EQUIPMENT MEMO ...