6 - 12
6. GENERAL GAIN ADJUSTMENT
6.5 Differences in auto tuning between MELSERVO-J2 and MELSERVO-J2-Super
To meet higher response demands, the MELSERVO-J3 series has been changed in response level setting
range from the MELSERVO-J2S-Super series. The following table lists comparison of the response level
setting.
MELSERVO-J2-Super
MELSERVO-J3
Parameter No. 9 Setting
Guideline for Machine Resonance
Frequency [Hz]
Parameter No. PA09 Setting
Guideline for Machine Resonance
Frequency [Hz]
1
10.0
2
11.3
3
12.7
1
15
4
14.3
5
16.1
6
18.1
2
20
7
20.4
8
23.0
3
25
9
25.9
4
30
10
29.2
11
32.9
5
35
12
37.0
13
41.7
6
45
14
47.0
7
55
15
52.9
16
59.6
8
70
17
67.1
18
75.6
9
85
19
85.2
20
95.9
A
105
21
108.0
22
121.7
B
130
23
137.1
C
160
24
154.4
25
173.9
D
200
26
195.9
27
220.6
E
240
28
248.5
29
279.9
F
300
30
315.3
31
355.1
32
400.0
Note that because of a slight difference in gain adjustment pattern, response may not be the same if the
resonance frequency is set to the same value.