5 - 14
5. PARAMETERS
No.
Symbol
Name and Function
Initial
Value
Unit
Setting
Range
PB18
LPF
Low pass filter setting
Set the low pass filter.
Setting parameter No. PB23 (low pass filter selection) to " 0 " automatically
changes this parameter.
When parameter No. PB23 is set to " 1 ", this parameter can be set manually.
3141
rad/s
100
to
18000
PB19
VRF1
Vibration suppression control - vibration frequency setting
This parameter cannot be used in the speed control mode.
Set the vibration frequency for vibration suppression control to suppress low-frequency
machine vibration, such as enclosure vibration. (Refer to Section 7.4.(4))
Setting parameter No. PB02 (vibration suppression control tuning mode) to " 1"
automatically changes this parameter. When parameter No. PB02 is set to " 2",
this parameter can be set manually.
100.0
Hz
0.1
to
100.0
PB20
VRF2
Vibration suppression control - resonance frequency setting
This parameter cannot be used in the speed control mode.
Set the resonance frequency for vibration suppression control to suppress low-
frequency machine vibration, such as enclosure vibration. (Refer to Section 7.4.(4))
Setting parameter No. PB02 (vibration suppression control tuning mode) to " 1"
automatically changes this parameter. When parameter No. PB02 is set to " 2",
this parameter can be set manually.
100.0
Hz
0.1
to
100.0
PB21
0.00
PB22
For manufacturer setting
Do not change this value by any means.
0.00
PB23
VFBF
Low pass filter selection
Select the low pass filter.
Low pass filter selection
0: Automatic setting
1: Manual setting (parameter No. PB18 setting)
0 0
0
When automatic setting has been selected, select the filter that has the band width close
to the one calculated with
VG2 10
1 + GD2
[rad/s]
0000h
Refer to
Name
and
function
column.
PB24
*MVS
Slight vibration suppression control selection
Select the slight vibration suppression control and PI-PID change.
When parameter No. PA08 (auto tuning mode) is set to " 3", this parameter is
made valid. (Slight vibration suppression control cannot be used in the speed control
mode.)
Slight vibration suppression control selection
0: Invalid
1: Valid
0 0
PI-PID control switch over selection
0: PI control is valid. (Switching to PID
control is possible with instructions of
controller.)
3: PID control is always valid.
0000h
Refer to
Name
and
function
column.
PB25
For manufacturer setting
Do not change this value by any means.
0000h
Summary of Contents for MR-J3-B
Page 13: ...A 12 MEMO ...
Page 41: ...2 6 2 INSTALLATION MEMO ...
Page 141: ...7 16 7 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 215: ...11 52 11 OPTIONS AND AUXILIARY EQUIPMENT MEMO ...