3 - 24
3. SIGNALS AND WIRING
3.7.3 Source I/O interfaces
In this servo amplifier, source type I/O interfaces can be used. In this case, all DI-1 input signals and DO-1
output signals are of source type. Perform wiring according to the following interfaces.
(1) Digital input interface DI-1
EM1,
etc.
Servo amplifier
Switch
Approx. 5mA
DICOM
V
CES
1.0V
I
CEO
100 A
24VDC 10%
150mA
Approx. 5.6k
(2) Digital output interface DO-1
A maximum of 2.6V voltage drop occurs in the servo amplifier.
If polarity of diode is
reversed, servo
amplifier will fail.
Servo amplifier
ALM,
etc.
Load
DOCOM
24VDC 10%
150mA
Summary of Contents for MR-J3-B
Page 13: ...A 12 MEMO ...
Page 41: ...2 6 2 INSTALLATION MEMO ...
Page 141: ...7 16 7 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 215: ...11 52 11 OPTIONS AND AUXILIARY EQUIPMENT MEMO ...