- 25 -
4. INITIAL SETTING
4-1. Installation of the system
(1) When operate the perfect stitch unit, it is necessary to install the system file. The system file is
included with this device.
(2) Refer to the instructions in the paragraph [6 Set up] in the PLK-J-CU-20S CONTROL UNIT technical
manual, install the system file.
(3) After the installation is completed, select the model data [JP2516RY].
4-2. How to operate jig clamp
(1) Push the jig <1> in the arrow direction and contact with clamp lever <2>.
(2) Furthermore, insert the jig toward the U-shaped groove <3>. In this position, the jig <1> is locked.
(3) At the same time, set the opposite side jig.
(4) Check if the jig locked perfectly by moving the jig <1> or the work clamp.
(5) When remove the jig <1>, push the clamp lever <2> in the arrow direction.
The jig <1> is ejected automatically by the jig ejector <4>.
<1>
<2>
<3>
<1>
<2>
<4>
<1>: Jig
<2>: Clamp lever
<3>: U-shaped groove
<1>: Jig
<2>: Clamp lever
<4>: Jig ejector