- 20 -
3-14. Connection of the electric cables
According to following procedures wiring the [
θ axis and digital tension axis motor cable <1>] and [θ axis
and digital tension axis encoder cable <2>] which included in this devices package.
(1) Remove the existing digital tension motor cable and existing digital tension encoder cable completely
by removing the connector which connecting digital tension axis motor <3> and MIF board.
(2) Connect the [
θ axis and digital tension axis motor cable <1>] and [θ axis and digital tension axis
encoder cable <2>] to the digital tension axis motor <3> according to following figure.
Note When connect the encoder cable match the
“D” marking indicated on connector.
<1>
<2>
<3>
<1>
<2>
<1>:
θ axis and digital tension axis motor cable
<2>:
θ axis and digital tension axis encoder cable
<3>: Digital tension axis motor
<1>
θ axis and digital tension axis motor cable
<2>
θ axis and digital tension axis encoder cable