Drain the water tank before use

Refrain from opening  
doors/windows during operation

Drying laundry indoors

Maintain room temperature above 16°C with a 

heater

 

z

Drying times will vary depending on the nature 

of the laundry and the room temperature. In low 

temperatures (10°C), drying takes about twice as 

long as when normal (20°C+).

 

z

The airflow is strongest to the top right of the unit.

Installing your dehumidifier 

Make sure to leave some  

space around the unit.
<For use in close proximity 

to a wall>

Stop the louvre in the 

vertical position. Blowing 

air at the wall may cause 

staining.

Operating noise

Place the unit on top of a mat. This reduces vibration and 

noise. It also prevents leaving depressions on carpets.

At least 

20 cm

At least 50 cm

At least 

2 cm

At least 20 cm

At least 

20 cm

• Direct the louvres at the laundry.

• Space laundry to improve airflow.

• Space the washing to ensure good air flow.

Precautions (Cont.)

Use the dehumidifier in  a small, enclosed r

oom.

z

  Keep the unit always in an upright 

position.

 Inclining the unit may cause water 

in the tank to leak into the unit, 

resulting in 

malfunction

. Should this happen contact 

service number on the last page for advice.

z

 

Damage to the dehumidifier caused by 

atmospheric conditions (ie. Salt or Sulphur) will 

not be covered under warranty.

When draining water 

continuously or left 

unattended for long periods, 

inspect the unit every two 

weeks.

Do not allow debris to clog the 

filter/hose as this may cause 

overheating/leakage

.

Use the unit with caution 

in rooms where the walls, 

furniture and art work are 

vulnerable to dry air, as 

it may cause cracks and 

warping.

Switch the unit off 

and unplug from 

the power source 

when cleaning it.

When the unit is on, the internal fan 

rotates at high speeds and may 

cause 

injury

.

Unplug the unit from the 

power source when not using 

the unit for an extended 

period of time.

Otherwise it may cause 

fire and/

or electric shock caused by an 

electric leak

.

Tips on Dehumidifying

z

  Do not carry the unit horizontally.

This may 

result in malfunctions

.

Such malfunctions are 

NOT covered under 

warranty.

Warnings

CAUTION

 

z

This appliance is not intended for use by 
persons (including children) with reduced 
physical, sensory or mental capabilities, or lack 
of experience and knowledge, unless they have 
been given supervision or instruction concerning 
use of the appliance by a person responsible for 
their safety.

 

z

Children should be supervised to ensure that 
they do not play with the appliance.

e_mj_e16vx_a1.indb   6

2016/06/27   14:37:58

Summary of Contents for MJ-E16VX-A1

Page 1: ... 7 Unit Control Panel LCD Panel Low Temperature Defrost High Humidity z z Things to Be Aware of 10 z z Before Using Your Dehumidifier 10 z z Turning the Unit ON and OFF 12 To turn ON To turn OFF Reading the humidity display Tank full lamp z z Easy Operation 13 EASY DEHUMIDIFYING LAUNDRY z z Setting Modes 14 LOW MILDEW GUARD LOW TEMP AUTO AIR PURIFIER z z Swing Louvre Function 16 z z Drying Inside ...

Page 2: ...indoors To prevent mildew LAUNDRY The unit operates for 12 hours and automatically switches off EASY DEHUMIDIFYING The unit operates until the air is comfortable AUTO The unit maintains the set humidity LOW TEMP The unit changes the airflow according to room temperature MILDEW GUARD The unit operates in mildew suppression mode UPWARD Aim toward clothes Turn the power on Select LAUNDRY Select EASY ...

Page 3: ...the graph below Although only a little water collects in the tank this is not a malfunction Winter dampness If the temperature is low but the humidity is high due to snow or rain operating the unit in LOW TEMP mode will yield better results than in LOW mode 14 The values shown on the graph were measured at constant temperature and humidity and do not reflect values obtained in actual usage conditi...

Page 4: ... any long object into the air intake outlet Do not touch the swing louvre The internal fan rotates at high speeds and such actions may result in injury or malfunctions Do not attempt to repair disassemble or modify the unit This may result in fire and or electric shock See the last page for service contact details Do not put the unit near heat generating devices such as stoves fan heaters etc The ...

Page 5: ...nit in places that may be subject to oil or flammable gas leakage Such a leak around the unit may cause combustion and fire Do not remove the Styrofoam from the floating element The floating element will not be able to detect a full tank resulting in water leakage which may damage surrounding objects or cause electric shock and or an electric leak Do not wash the unit with water Do not use the uni...

Page 6: ...ast page for advice l Damage to the dehumidifier caused by atmospheric conditions ie Salt or Sulphur will not be covered under warranty When draining water continuously or left unattended for long periods inspect the unit every two weeks Do not allow debris to clog the filter hose as this may cause overheating leakage Use the unit with caution in rooms where the walls furniture and art work are vu...

Page 7: ... photocatalysis constantly renewing the air freshening properties As the filter s particle and air freshening properties are renewed by simply soaking and leaving it to dry in the sun the filter can be used continuously over a long time Cigarette smoke and toxins found in smoke such as carbon monoxide cannot be removed with this filter Diameter of pollen approx 10 100 μm The water tank may contain...

Page 8: ...swing louvre direction or locks it into position 16 18 19 z z ON OFF timer button Sets timer LCD Panel z z Mode indicator Indicates the current operating mode 14 15 z z Humidity indicator This indicates the approximate humidity indicates the current humidity indicates the humidity setting in AUTO mode The current humidity is displayed in a range from 30 to 80 12 z z Swing monitor Indicates the dir...

Page 9: ...rt automatically when room temperature drops below 15 C This may be as often as once every 40 minutes z z Mildew guard elite lamp Flashes when drying inside in progress z z Mildew guard elite button Activate deactivates drying inside 17 z z Air purifier lamp Lights during air purifier only operation z z Air purifier button Switches to air purifier only operation 15 z z Information display Indicate...

Page 10: ...il causing the moisture to transform into water droplets 2 The water droplets fall into the water tank 3 The dehumidified air is reheated by the heating coil and then discharged The humidity of the room is thus reduced by repeating steps 1 2 and 3 Room temperature may rise 2 4 C during operation The dehumidifier does not have a cooler function Due to heat produced during operation the room tempera...

Page 11: ...hat the lid is securely attached to the water tank Push the tank in Front door Plug the power cord into the power socket Use a 230 240V AC power socket only The current humidity level is indicated If the louvre is open it closes automatically ur Dehumidifier e_mj_e16vx_a1 indb 11 2016 06 27 14 37 59 ...

Page 12: ...he compressor When dehumidifying begins the operational noise increases The dehumidifier remembers the operating mode Even if the plug is disconnected or the power turned off the unit restarts at the previous setting Reading the humidity display Tank full lamp 9 Turning the Unit ON and OFF Press To turn OFF Drying inside will commence if it has been activated 17 Press z z Power lamp turns off z z ...

Page 13: ... 30 27 60 Room temperature is below 27 C the unit automatically sets the humidity level according to the temperature Room temperature is above 27 C the unit lowers the humidity level to 50 then activates the blower The dehumidifier is reactivated when humidity rises to 60 Humidity level Room temperature C Information z z Drain the tank before use The unit may stop before the laundry dries because ...

Page 14: ...tinuously automatically controlling airflow according to room temperature The air flow is strongest below 15 C The use of LOW TEMP mode is recommended when the Low temperature indicator is lit 9 When the temperature is low condensation may still form on windows exposed to the outside air even when LOW TEMP mode is operating Information How is mildew growth suppressed Mildew is unable to produce ne...

Page 15: ...ing the power on Information Frequent use of exits and room size conditions may cause the humidity to not reach the set level To view set humidity level To set humidity level Pressing the button once displays the set humidify level with the indicator After 3 seconds the display returns to the current humidity display Pressing the button while is displayed sets the humidity level Each time the butt...

Page 16: ...For directing air into a closet REAR The louvre moves slowly through the last 30 of the swing as the time taken to traverse the rear arc is shorter than that for the upward arc when moving at a constant speed Information z z The level of noise emitted from the unit varies according to the angle of the air flow z z The louvre may stop up to a maximum of 8 seconds to correct its position after which...

Page 17: ... flashes the humidity indicator turns off and the louvre stops in the vertical position Drying inside mode z z Drying inside ends The mildew guard elite lamp turns off and the louvres shut To deactivate automatic operation Press the mildew guard elite button while the unit is on the mildew guard elite lamp turns off Manual operation To activate drying inside by pressing a button Press while the un...

Page 18: ...13 15 Select desired operating mode 3 Change the louvre swing direction 16 Select the desired setting 4 Set the operation time z z When pressed once the figure and OFF appear z z Each subsequent press changes the display in order from 1 to 9 hours Hold the button to run automatically through the numbers The OFF timer is set The following is an example of a display indicating AUTO dehumidifying set...

Page 19: ...ially available timer plug outlet Press To set 1 Switch the power off 12 2 Set the time you wish the unit to turn on z z Press once The Power lamp Mode indicator and a on the digital display flash The ON indicator lights z z Each subsequent press changes the display in order from 1 to 9 hours Hold the button to run automatically through the numbers 3 Select operating mode 13 15 Select desired oper...

Page 20: ...R button to turn it on Only the CHILD LOCK indicator will blink Press the POWER button once again so that the indicator turns on If you lock the unit when the POWER is ON The unit will not turn off even if you press the POWER button to turn it off Only the CHILD LOCK indicator will blink Press the POWER button once again so that the indicator turns on Pull the handle out and grasp with a firm grip...

Page 21: ...the front door z z If the lid is not properly closed you may have problems removing the tank z z If the tank is not installed correctly the tank full lamp will come on and the unit will not operate Open the front door Grasp handle and slide out Hold the tank this way Tank lid Pour the water out as shown Note Do not remove or dismantle the floating element in the tank If it is removed the unit cann...

Page 22: ...led Incorrectly installed z z Hose immersed in water z z Hose raised to a level higher than the drainage outlet gThe water will not drain Note z z Leave a minimum space of 20 cm behind the unit for attaching the hose z z Confirm that the hose does not show signs of deterioration such as cracks and clogging z z Inspect the hose every 2 weeks Insects or dirt blocking the hose may cause leakage resul...

Page 23: ...o gradually become dirty If the dirt does not come off easily wash with cold or warm water then wipe with a soft dry cloth z z Mildew may form in the tank unless kept clean Once every two weeks Pre filter Debris clogging the pre filter reduces the effectiveness of the dehumidifier Clean once every 2 weeks For maintenance procedures see 10 1 Remove the front panel and pre filter 2 Remove the photoc...

Page 24: ...kewarm water for 30 minutes Once every three months Photocatalytic filter Maintenance Cont 4 Dry the photocatalytic filter Do not hang with pegs as this may damage the filter Do not use the filter while wet 5 Fit the photocatalytic filter With the strips facing up set the photocatalytic filter inside the tabs on the pre filter 6 Attach the pre filter and front panel Dry well in the sun The perform...

Page 25: ...e pre filter 23 5 Store the unit When you are sure that all parts of the unit are dry cover it with a cloth to keep it from dust Store the unit in an upright position in a place not exposed to direct sunlight Storage 17 When disposing the unit Dispose according to the garbage regulations in your district z z Photocatalytic filter Material PET and PS z z Unit Do not disassemble Dispose according to...

Page 26: ...ove as set z z The residue is from final product testing at the factory It is not a result of a malfunction The water tank contains liquid or white water residue z z The residue is from debris in the air Clean according to the maintenance procedures 23 There is black residue on the inside of the water tank and lid z z Check to see if the power cord is correctly plugged Plug the power cord properly...

Page 27: ...produces a simmering sound The unit produces a buzz that sounds intermittently or the compressor does not activate When first used z z The heat converter heats rapidly causing a brief odour This is not a malfunction z z The moisture expelled from inside the unit may smell due to odorants that were not caught by the photocatalytic filter dissolving in the water This is not a malfunction The unit pr...

Page 28: ...0 It indicates the amount of dehumidification per day 24 hours z z Standby power approximately 1 5 W It is impossible to remove the back panel because the two spots shown are fastened with two special screws If the unit malfunctions contact your Mitsubishi dealer NOTE Auckland Unit 1 4 Walls Rd PO Box 12726 Penrose Auckland Phone 09 526 9347 Fax 09 526 9348 Wellington 1 Parliament St PO Box 30772 ...