background image

Commercial Dehumidifier

HME020437N

Thank

 you 

for

 pur

chasing our

 quality

 appliance. Please be sur

to r

ead 

the en

tir

ety

 

of

 this user

 manual

 car

efull

y prior

 to use o

the pr

oduct. If

 you ha

ve an

y questions 

regar

ding 

the use o

this pr

oduct, please call

 1-800-898-

3002.

Summary of Contents for HME020437N

Page 1: ...437N Thank you for purchasing our quality appliance Please be sure to read the entirety of this user manual carefully prior to use of the product If you have any questions regarding the use of this product please call 1 800 898 3002 ...

Page 2: ... stored where it cannot be used again by mistake Failure to retain the product may impede hOme s ability to correct any legitimate problem and may limit the extent to which hOme may provide recourse BEFORE FIRST USE To prevent any internal damage it is very important to keep refrigeration units like this one upright throughout their journey Please leave it standing upright and outside the box for ...

Page 3: ...Important Safety Instructions Installation Operation Cleaning and Maintenance Specification Troubleshooting Warranty Manufacturing Info Warning Contact Us 6 7 8 11 12 13 14 15 15 15 15 TABLE OF CONTENTS ...

Page 4: ......

Page 5: ... appliance Congratulations Don t forget to register your product at homelabs com reg for updates coupons and other relevant information Although greatly appreciated product registration is not required to activate any warranty ...

Page 6: ...let or outlet openings Do not operate in close proximity to walls curtains or other objects that may block the inlet and outlet This unit must be plugged into a grounded outlet To reduce the risk of electric shock do not expose the unit or flexible cord to moisture of any kind Turn off and unplug from the power socket when not in use before assembling or before cleaning Do not attempt to dismantle...

Page 7: ...imum capacity of the water pump is 16 4ft If the water is drained downwards there is no limit for the distance Press and hold DRAIN button to drain the water manually The water pump will work for 20 seconds before stopping Repeat until all water is drained Drain the water manually before storing or moving the unit WARNING Do not block the drain hose The end of the drain hose should not be higher t...

Page 8: ...8 Operation PARTS DESCRIPTION Handle Control panel Air inlet Universal castors Wheel Air outlet Power cord hooks Radiator grille Drainage port Built in handle ...

Page 9: ... off the appliance press POWER button the screen displays and the appliance goes into standby mode The fan will run for another minute before stopping To set the timer Press TIMER button while the appliance is off the timer indicator will light up Press DECREASE or INCREASE button to set the time to start the appliance When the countdown is over the fan and the compressor will turn on Press TIMER ...

Page 10: ...fter 30 seconds the water pump will stop working and the FULL indicator will light off Press DRAIN button to pump the water out even when it s not full The pump will work for 30 seconds and the FULL indicator will turn on and off accordingly Operation The system has auto memory If there is a sudden power cut during operation the system restores the last settings before the power cut and will resum...

Page 11: ...be replaced Please call customer service for further support Protection codes E4 The water full switch sensor fails or the water pump fails CL The room temperature is lower than 41 F The appliance stops running CH The room temperature is higher than 100 4 F The appliance stops running LO The room humidity is lower than 20 RH The appliance stops running HI The room humidity is higher than 95 RH The...

Page 12: ...rease the appliance s efficiency Clean the filter with potable water at least once every 30 days Storage requirements If not use the unit for an extended period of time store it per the following steps Clean the filter ATTENTION The evaporator inside the appliance has to be dried out before the unit is packed to avoid component damage Unplug the unit and place it in a dry open area for days to dry...

Page 13: ...ower Consumption Current 515W 5 05A 65 F 60 RH 635W 6 0A 80 F 60 RH 728W 6 75 A 86 F 80 RH 830W 8 0A 95 F 90 RH Noise 60dB A Air Circulation 265CFM Refrigerant Type Capacity R410A 11 6Oz 330g Minimum Current of Power Supply 15A Maximum Design Pressure High Side 522psig 3 6MPa Low Side 240psig 1 65MPa Compressor Input RLA 6 4A LRA 38A Fan Motor Power 0 100HP ...

Page 14: ... There is a kerosene heater or something giving off water vapor in the room Allow enough time to remove the moisture Reset the humidity level Check that all doors windows and other openings are securely closed Remove the objects giving off water vapor in the room Reduced dehumidifier capacity The filter mesh is jammed Clean the filter mesh The air in and or air out louvers are jammed Clear the blo...

Page 15: ...e recommend that you register your product on our website homelabs com reg Although greatly appreciated the product registration is not required to activate any warranty and product registration does not eliminate the need for the original proof of purchase The warranty becomes void if attempts at repair are made by non authorized third parties and or if spare parts other than those provided by hO...

Page 16: ... 2020 hOmeLabs LLC 37 East 18 Street 7th Floor New York NY 10003 1 800 898 3002 help homelabs com homelabs com help All rights reserved hOme Printed in China ...