10
Operation
To set the humidity level
The default set humidity level is 50%RH. To increase or decrease the humidity level, press and hold
DECREASE
or
INCREASE
button. The humidity level can be increased or decreased by increments of 5%RH
in normal mode.
Note:
Environmental humidity and appliance set humidity will decide the status of the compressor and fan
as follow:
•
If the environmental humidity ≥ appliance set h3%, the compressor and the fan will start
running.
• If the environmental humidity < appliance set humidity-3%, the compressor and the fan will stop
running.
To use the continuous mode
In continuous mode, humidity setting is invalid. The continuous mode indicator turns on and the screen
will display the current humidity. To exit the continuous mode, press
CONT.
button. The humidity setting is
resumed.
Water drainage
• When the water pump is full, the water pump will start automatically. The “FULL” indicator will
light in red. After 30 seconds, the water pump will stop working and the "FULL" indicator will light
off. Press
DRAIN
button to pump the water out even when it's not full. The pump will work for 30
seconds and the "FULL" indicator will turn on and off accordingly.
Operation
• The system has auto memory. If there is a sudden power cut during operation, the system restores
the last settings before the power cut and will resume operation upon power resumption.
Defrost Function
1. The appliance will defrost automatically when it is operating at low temperatures. However, the
compressor and the fan will shut off if the environmental temperature is below 41 °F or above
100.4 °F.
2. After the compressor ran for 30 minutes, the temperature sensor will detect the copper pipe
temperature. When the detected temperature is ≤30.2°F in the last 10 seconds, the compressor will
stop and start to defrost. The fan will keep working and the defrost indicator will turn on. When
the pipe temperature reaches 41°F or the defrost lasts for 15 minutes, the appliance quits the
defrosting.
Note:
During the defrosting, the indicator light will not be off until the defrosting is over.