11
Operation
Error codes
In case of malfunction, the appliance will display an error code.
E1 - Temperature sensor fails. The system will work in cycles of dehumidification for 30 minutes and
defrosting for 15 minutes. The temperature sensor needs to be replaced. Please call customer service for
further support.
E2 - Humidity sensor fails. The humidity adjusting button will not work. The system will work in cycles of
dehumidification for 30 minutes and defrosting for 15 minutes. The humidity sensor needs to be replaced.
Please call customer service for further support.
Protection codes
E4 - The water full switch sensor fails or the water pump fails.
CL - The room temperature is lower than 41°F. The appliance stops running.
CH - The room temperature is higher than 100.4°F. The appliance stops running.
LO - The room humidity is lower than 20%RH. The appliance stops running.
HI - The room humidity is higher than 95%RH. The appliance is working normally.
Note:
When one of the above malfunctions occurs, turn off the dehumidifier, and check for any
obstructions. Restart the dehumidifier, if the malfunction is still present, turn off the dehumidifier and
unplug the power cord. Contact Customer Service for repair and/or replacement.
Summary of Contents for HME020437N