22
INDOOR
-10
Q
INPUT
-5
Q
INPUT
0
Q
INPUT
5
Q
INPUT
10
Q
INPUT
15
Q
INPUT
20
Q
INPUT
15
21
26
2.14
2.04
1.84
534
585
626
2.58
2.45
2.28
651
693
735
3.03
2.89
2.69
735
768
810
3.47
3.30
3.13
793
827
868
3.91
3.74
3.57
843
868
910
4.32
4.15
3.98
868
893
935
4.76
4.57
4.42
885
927
960
PERFORMANCE DATA
HEATING operation
MFZ-KA25VA/ SUZ-KA25VA(H).TH
Rated frequency 80Hz
SUZ-KA25VA(H)R1.TH, SUZ-KA25VA2.TH Rated frequency 81Hz
CAPACITY : 3.4(kW) INPUT : 835(W)
MFZ-KA35VA/ SUZ-KA35VA(H).TH
Rated frequency 74Hz
SUZ-KA35VA(H)R1.TH, SUZ-KA35VA2.TH Rated frequency 75.5Hz
CAPACITY : 4.0(kW) INPUT : 1100(W)
MFZ-KA50VA/ SUZ-KA50VA(
1
).TH
Rated frequency 79Hz
SUZ-KA50VAR2.TH, SUZ-KA50VA2.TH Rated frequency 81Hz
CAPACITY : 6.0(kW) INPUT : 1860(W)
INDOOR
-10
Q
INPUT
-5
Q
INPUT
0
Q
INPUT
5
Q
INPUT
10
Q
INPUT
15
Q
INPUT
20
Q
INPUT
15
21
26
INDOOR
-10
Q
INPUT
-5
Q
INPUT
0
Q
INPUT
5
Q
INPUT
10
Q
INPUT
15
Q
INPUT
20
Q
INPUT
15
21
26
3.78
3.60
3.24
1209
1302
1395
4.56
4.32
4.02
1451
1544
1637
5.34
5.10
4.74
1637
1711
1804
6.12
5.82
5.52
1767
1841
1934
6.90
6.60
6.30
1879
1934
2027
7.62
7.32
7.02
1934
1990
2083
8.40
8.07
7.80
1972
2065
2139
2.52 715 3.04 858 3.56 968 4.08 1045 4.60 1111 5.08 1144 5.60 1166
2.40 770 2.88 913 3.40 1012 3.88 1089 4.40 1144 4.88 1177 5.38 1221
2.16 825 2.68 968 3.16 1067 3.68 1144 4.20 1199 4.68 1232 5.20 1265
OUTDOOR WB(°C)
DB(°C)
OUTDOOR WB(°C)
DB(°C)
OUTDOOR WB(°C)
DB(°C)
NOTE
: Q :Total capacity (kW) INPUT :Total power input (W) DB: Dry-bulb temperature WB: Wet-bulb temperature
OB409E