6 SYSTEM CONSTRUCTION
6.7 Connection of an I/O Module
77
6
Connection example of a CIO-1400 I/O module
This section shows an example for connecting a CIO-1400 I/O module.
Sink type
• Input module (positive/negative common shared type)
• Output module (sink type)
Source type
• Input module (positive/negative common shared type)
• Output module (source type)
24 VDC
power supply
High-speed output 1
High-speed output 0
24 VDC
Trigger
24 VDC
GND
General-purpose input 1
Input common
General-purpose output 3
General-purpose output 2
Output common
24 VDC
power supply
Trigger
24 VDC
GND
GND
General-purpose input 1
Input common
General-purpose output 3
General-purpose output 2
General-purpose output 5
General-purpose output 4
Output common