64
6 SYSTEM CONSTRUCTION
6.3 Attachment of a Lens and Light
Attachment of an S-mount/M12 manual focus lens
Attach an S-mount/M12 manual focus lens by following the procedure below.
Operating procedure
1.
Remove the rubber faceplate covering the image sensor window.
2.
Remove the protective film covering the threaded lens opening (if present).
3.
Place an S-mount adapter over the image sensor window.
4.
Place the "In-Sight" end of the adapter tool on the S-mount adapter, and turn clockwise until tight.
5.
Remove the adapter tool, and turn a lens clockwise to tighten.