3. Setting
■
Basic Operations for setting
Function
Operation
Remarks
Select a set value
Press or .
Fast-forward when pressed over 1 sec.
Setting items are saved
Press .
Setting item will be cared and shift to the
next item.
Go back to the previous setting item
Press .
The set value for the setting item just before
Skip removing setting items returning is still
available.
Skip removing setting items
during setting
Press and hold for 1 sec.
3.2 Setting menu 1: Basic Settings (Setting the Phase Wire System, Display Pattern, VT/Direct Voltage,
CT Primary Current, etc.)
Set the phase wire method, display pattern, VT/direct voltage, CT primary current, etc.
In the operation mode, after pressing
and
simultaneously for 2 seconds or more, the following operation becomes
availa
ble.
SET
DISPLAY
RESET
SET
SET
+
-
Set the display pattern.
The following table shows the measurement elements that can be displayed by
each display pattern. (For more details about display patterns, refer to page 61,62.)
In addition, if there is no display pattern that you want from P01 to P13),
select the special display pattern P00 to configure the screen freely.
( For more information about setting the special display pattern P00,
refer to page38,39.)
○:
Displayable at this display setting.
△:
Set at other additional settings.
□:
Select "P00" and set the display order and display position.
②
Display Pattern
Set the phase wire system.
Supplemental Information:
Underlined portions indicate
the default values.
(Same from here.)
①
Phase Wire system
3P4
: 3-phase 4-wire
3P3
.
2CT : 3-phase 3-wire
(
2CT
)
3P3
.
3CT : 3-phase 3-wire
(
3CT
)
1P3
.
1N2 : 1-phase 3-wire
(
1N2 display
)
1P3
.
1N3 : 1-phase 3-wire
(
1N3 display
)
1P2
: 1-phase 2 -wire
Set the setting menu number to “1”.
(as shown in the right figure)
Setting Menu
SET
DISPLAY
SET
DISPLAY
SET
DISPLAY
(
1
)
For 3-phase 4-wire
D
is
pl
ay
P
at
ter
n
C
ur
rent
N
P
h
as
e C
ur
ren
t
C
ur
rent
D
ema
nd
N
P
h
as
e
C
ur
ren
t
D
e
man
d
V
ol
tag
e
A
c
ti
v
e P
ow
er
P
ow
er
F
ac
tor
R
eac
ti
v
e
P
ow
er
A
pp
ar
ent
P
ow
er
F
requenc
y
A
c
ti
v
e E
ner
gy
(I
m
por
te
d
)
A
c
ti
v
e E
ner
gy
(E
x
p
or
ted)
R
eac
ti
v
e E
n
er
gy
(I
mpor
te
d
L
AG
)
A
pp
ar
ent
E
n
er
gy
Additional display
A
c
ti
v
e
E
ner
gy
(
Impor
ted
)
A
c
ti
v
e E
ner
gy
(E
x
p
or
ted)
R
eac
ti
v
e E
n
er
gy
(S
pec
ial
)
A
pp
ar
ent
E
n
er
gy
P
er
iodi
c
A
c
ti
v
e E
n
er
gy
R
ol
lin
g D
e
ma
nd
H
ar
mon
ic
C
ur
ren
t/
V
ol
tag
e
D
ig
it
a
l I
n
p
u
t/
O
ut
pu
t
O
per
at
ion t
im
e
P01
○
○
○
○
○
△
△
△
△
△
P02
○
○
○
○
○
○
○
△
△
△
△
△
△
P03
○
○
○
○
○
○
○
○
△
△
△
△
△
P04
○
○
○
○
○
○
○
○
○
○
○
○
△
△
○
△
△
△
△
△
P05
○
○
○
○
○
△
△
△
△
△
P06
○
○
○
△
△
△
△
△
P07
○
○
○
○
△
△
△
△
△
P08
○
○
○
○
○
○
△
△
△
△
△
△
P09
○
○
○
○
○
△
△
△
△
△
P10
○
○
○
○
○
○
△
△
△
△
△
P11
○
○
○
○
○
○
○
△
△
△
△
△
△
P12
○
○
○
○
○
○
○
○
△
△
△
△
△
△
P13
○
○
○
○
○
○
○
○
○
○
○
○
△
△
○
△
△
△
△
△
P00
□
□
□
□
□
□
□
□
□
□
□
□
□
□
△
△
△
△
△
△
△
△
△
Note: The following settings are required for displaying elements on an additional display.
Measurement element on additional display
Setting item
Reference
Pages
Active energy Exported /reactive energy
Special(*)
Setting Menu 3 Active energy measurement
Page 22
Harmonic current/ Harmonic voltage
Setting Menu 3 Harmonics display
Page 22
Periodic Active Energy
Setting Menu 7 Periodic Active energy display
Page 32
Rolling Demand
Setting Menu 7 Rolling demand display
Page 32
Digital input / output status
Setting Menu 7 Digital input / output display
Page 33
Operation time
Setting Menu 8 Operation time display
Page 34
※
When display elements does not set active energy/ reactive energy/ apparent energy, ’P00’ of active
energy/ reactive energy/ apparent energy on additional display does not appear.