(3/56)
3. Communication Parameter
Set each communication parameters to the PC connected with each kind of cable.
A: RS-232C connection
(1)
RS-232C direct connection between PC and Display
Interface
RS-232C (
Asynchronous, Full-duplex)
Baud rate
9600bps
Data length
8bits
Parity
None
Stop bit
1 bit
Flow control
None
Communication code
ASCII
Communication signals
TXD, RXD
B: CAT5 (OPTION) RS-485 connection
(1)
USB connection between PC and CAT5 Tx BOX
Interface
RS-232C (
Asynchronous, Half-duplex)
via USB driver
Baud rate
9600bps
Data length
8bits
Parity
None
Stop bit
1 bit
Flow control
None
Communication code
ASCII
Communication signals
TXD, RXD, RTS
Note: Set the parameters on to USB driver properties. RTS is negative polarity.
(2)
RS-232C connection between PC and CAT5 Tx BOX
Interface
RS-232C (
Asynchronous, Half-duplex)
Baud rate
9600bps
Data length
8bits
Parity
None
Stop bit
1 bit
Flow control
None
Communication code
ASCII
Communication signals
TXD, RXD, DTR
Note: DTR is negative polarity.
C: LAN connection
(1) LAN connection between PC and Display
Interface
TCP/IP
DHCP client mode
Changeable (default = OFF: not using)
IP address
Changeable (default = 192.168.0.10: depends on model)
Subnet mask
Changeable (default = 255.255.255.0)
Default gateway
Changeable (default = 192.168.0.1: depends on model)
Port
MDT652S:63007/3007(Both of those ports are available. Use
63007 only if you have no support of legacy products.)