(25/56)
0004: OFF (same as the power off by IR)
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet.
8. Asset Data read and write
8.1 Asset Data Read Request and reply
This command is used in order to read Asset Data.
1) The controller requests the monitor to reply with Asset data.
Header Message
Check
code
Delimiter
SOH-'0'-'A'-'0'-'A'-'0'-'A' STX-'C'-'0'-'0'-'B'-'0'-'0'-'2'-'0'-ETX
BCC
CR
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
'A' (41h): Monitor ID
If the command should be sent to certain monitor only, the either of character ‘A’(41h) to ‘Z’(5Ah)
which is corresponding to monitor ID from No1 to No.26 should be set to this portion.
'0' (30h): Message sender is the controller
'A' (41h): Message type is "Command"
'0'-'A' (30h, 41h): Message length is 10 bytes
Message
STX (02h): Start of Message
'C'-'0'-'0'-'B' (43h, 30h, 30, 42h): Asset read request command
'0'-'0' (30h, 30h): Offset data from top of the Asset data.
At first set 00h: Read data from the top of Asset data area.
'2'-'0' (32h, 30h): Read out data length is 32bytes.
Maximum readout length is 32bytes at a time.
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies Asset data to the controller.
Header Message
Check
code
Delimiter
SOH-'0'-'0'-'A'-'B'-N-N STX-'C'-'1'-'0'-'B'-
Data(0)-Data(1)---Data(N)-ETX
BCC CR
Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller
'A' (41h): Monitor ID
This portion should depend on the monitor ID of Monitor.( ’A’(41h)-‘Z’(5Ah)).
'B' (42h): Message type is "Command reply"
N-N: Message length
Ex.) The byte data 20h is encoded to ASCII characters '2' and '0' (32h and 30h).
Note.) This length is includes STX and ETX.
Message