(52/56)
Item OP
code
page
OP code
Parameter
Remarks
Factory Reset
00h
04h
1: Reset
Momentary
Configuration Reset
N/A
OSD Turn Off
00h
FCh
0-4:Do not set.
5:5sec
|
120:120sec
Information OSD
02h
3Dh
0:disable information
OSD
3-10:
OSD timer [seconds]
Off Timer
02h
2Bh
0: OFF
1: 1 hour
|
24: 24 hours
1 hour/step
H
Position
02h 38h
0:
|
MAX.:
OSD
Position
V
Position
02h 39h
0:
|
MAX.:
Configuration 2
Input Resolution
02h
DAh
1: Auto
2: 1024x768
3: 1280x768
4: 1360x768
Black Level
Expansion
02h 22h
1:
OFF
2: MIDDLE
3: HIGHT
Gamma Selection
02h
68h
Gamma
Table Selection
1: Native
Gamma
4: Gamma=2.2
8: Gamma=2.4
7: S Gamma
5:
Option(Dicom
simulate)
Scan Mode
02
h
E3h
1: OVER SCAN
2: UNDERSCAN
Scan Conversion
02h
25h
1: OFF(INTERLACE)
2: Enable
(IP ON/PROGRESSIVE)
Film Mode
02h
23h
1: OFF
2: AUTO
Monitor ID
02h
3Eh
1-26:ID
IR Control
02h
3Fh
1: Lock (Off) 3:Primary
2: Normal 4:Secondary
H monitor
02h
D0h
1
│
5
Number
of H-division
V monitor
02h
D1h
1
│
5
Number
of V-division
Position
02h
D2h
1: Upper left
│
MAX.: Lower right
Mode
02h
D3h
1: Disable (OFF)
2: Enable (ON)
Tiling
Frame
comp.
02h
D5h
1: Disable (OFF)
2: Enable (ON)
Advanced Option
Power On Delay
02h
D8h
0: OFF (0sec)
2,4,6,8,10,20,30,40,