
64
5 MODBUS/TCP (SLAVE)
5.2 Communication Setting
Bit device
The input relay (1) and the coil (0) each have 48 points. The remaining area becomes non-functioning and cannot be used.
• Input relay (1) (Master station
Slave station)
Device No.
Signal name
Signal name ON (data value=1)
OFF (data value=0)
100001
Run/Stop
Run
Stop
100002
Reel change B axis/A axis
B axis control
A axis control
100003
Control output OFF/ON
Control output OFF
Control output ON
100004
Auto/Manual
Automatic control
Manual control
100005
Stall memory ON/OFF
Stall memory ON
Stall memory OFF
100006
Gain 1 ON/OFF
Gain 1 ON
Gain 1 OFF
100007
Gain 2 ON/OFF
Gain 2 ON
Gain 2 OFF
100008
Inching ON/OFF
Inching ON
Inching OFF
100009
Cutting torque ON/OFF
Cutting torque ON
Cutting torque OFF
100010
Constant tension ON/OFF
Constant tension ON
Constant tension OFF
100011
Predrive ON/OFF
Predrive ON
Predrive OFF
100012
Memory hold ON/OFF
Memory hold ON
Memory hold OFF
100013
Reverse run/Forward run
Reverse run operation
Forward run operation
100014
100015
100016
100017
Alarm reset ON/OFF
Alarm reset ON
Alarm reset OFF
100018
Reel diameter reset ON/OFF
Reel diameter reset ON
Reel diameter reset OFF
100019
Measurement length and remaining
length reset ON/OFF
Measurement length and remaining length
reset ON
Measurement length and
remaining length reset OFF
100020
100021
100022
100023
100024
100025
Zero adjustment execution
Execution
Normal
100026
Span adjustment execution
Execution
Normal
100027
Maximum diameter teaching
execution
Start maximum diameter teaching execution
Normal
100028
Minimum diameter teaching
execution
Start minimum diameter teaching execution
Normal
100029
Control gain tuning execution
Start control gain tuning execution
Normal
100030
Speed teaching execution
Start speed teaching execution
Normal
100031
100032
100033
Data copy execution
Start data copy execution
Normal
100034
Data initial execution
Start data initial execution
Normal
100035
100036
100037
100038
100039
100040
100041
100042
100043
100044
100045
Link tension monitor digit
10/
1
Link tension monitor digit
10
Link tension monitor digit
1
100046
Continuous settings execution
Start continuous settings execution
Normal
Summary of Contents for LE7-40GU
Page 1: ...LE7 40GU INSTRUCTION MANUAL Communication ...
Page 2: ......
Page 10: ...8 TRADEMARKS 150 ...
Page 11: ...9 CONTENTS ...
Page 37: ...3 CC LINK IE FIELD NETWORK BASIC COMMUNICATION 3 3 Reference Program 35 3 ...
Page 38: ...36 3 CC LINK IE FIELD NETWORK BASIC COMMUNICATION 3 3 Reference Program ...
Page 39: ...3 CC LINK IE FIELD NETWORK BASIC COMMUNICATION 3 3 Reference Program 37 3 ...
Page 40: ...38 3 CC LINK IE FIELD NETWORK BASIC COMMUNICATION 3 3 Reference Program ...
Page 57: ...4 SLMP COMMUNICATION 4 3 Reference Program 55 4 Program example ...
Page 58: ...56 4 SLMP COMMUNICATION 4 3 Reference Program ...
Page 59: ...4 SLMP COMMUNICATION 4 3 Reference Program 57 4 ...
Page 60: ...58 4 SLMP COMMUNICATION 4 3 Reference Program ...
Page 61: ...4 SLMP COMMUNICATION 4 3 Reference Program 59 4 ...
Page 82: ...80 5 MODBUS TCP SLAVE 5 3 Reference Program Program example ...
Page 83: ...5 MODBUS TCP SLAVE 5 3 Reference Program 81 5 ...
Page 84: ...82 5 MODBUS TCP SLAVE 5 3 Reference Program ...
Page 85: ...5 MODBUS TCP SLAVE 5 3 Reference Program 83 5 ...
Page 86: ...84 5 MODBUS TCP SLAVE 5 3 Reference Program ...
Page 110: ...108 6 N N NETWORK 6 4 Reference Program Program example ...
Page 111: ...6 N N NETWORK 6 4 Reference Program 109 6 ...
Page 112: ...110 6 N N NETWORK 6 4 Reference Program ...
Page 147: ...7 MODBUS RTU ASCII SLAVE 7 4 Reference Program 145 7 Function code H03 Read holding register ...
Page 149: ...7 MODBUS RTU ASCII SLAVE 7 4 Reference Program 147 7 ...
Page 153: ......