20
3 CC-LINK IE FIELD NETWORK BASIC COMMUNICATION
3.2 Communication Setting
Link data configuration
LE7-40GU uses "1" for the number of occupied stations because the contents of the allocated link data does not change even
if the number of occupied stations of the CC-Link IE Field Network Basic slave station is changed.
*1 When using other than "1” for the number of occupied stations, all functions except remote input/output and remote register become
non-functioning.
Remote input/output
Each remote input/output has 48 points.
The remaining area becomes non-functioning and cannot be used.
• Remote output (Master Station
Slave Station)
Device No.
Signal name
Signal name ON (data value=1)
OFF (data value=0)
RY00
Run/Stop
Run
Stop
RY01
Reel change B axis/A axis
B axis control
A axis control
RY02
Control output OFF/ON
Control output OFF
Control output ON
RY03
Auto/Manual
Automatic control
Manual control
RY04
Stall memory ON/OFF
Stall memory ON
Stall memory OFF
RY05
Gain 1 ON/OFF
Gain 1 ON
Gain 1 OFF
RY06
Gain 2 ON/OFF
Gain 2 ON
Gain 2 OFF
RY07
Inching ON/OFF
Inching ON
Inching OFF
RY08
Cutting torque ON/OFF
Cutting torque ON
Cutting torque OFF
RY09
Constant tension ON/OFF
Constant tension ON
Constant tension OFF
RY0A
Predrive ON/OFF
Predrive ON
Predrive OFF
RY0B
Memory hold ON/OFF
Memory hold ON
Memory hold OFF
RY0C
Reverse run/Forward run
Reverse run operation
Forward run operation
RY0D
RY0E
RY0F
RY10
Alarm reset ON/OFF
Alarm reset ON
Alarm reset OFF
RY11
Reel diameter reset ON/OFF
Reel diameter reset ON
Reel diameter reset OFF
RY12
Measurement length and remaining
length reset ON/OFF
Measurement length and remaining length
reset ON
Measurement length and
remaining length reset OFF
RY13
RY14
RY15
RY16
RY17
RY18
Zero adjustment execution
Execution
Normal
RY19
Span adjustment execution
Execution
Normal
RY1A
Maximum diameter teaching
execution
Start maximum diameter teaching execution
Normal
RY1B
Minimum diameter teaching
execution
Start minimum diameter teaching execution
Normal
RY1C
Control gain tuning execution
Start control gain tuning execution
Normal
RY1D
Speed teaching execution
Start speed teaching execution
Normal
RY1E
RY1F
RY20
Data copy execution
Start data copy execution
Normal
RY21
Data initial execution
Start data initial execution
Normal
RY22
RY23
RY24
RY25
RY26
Summary of Contents for LE7-40GU
Page 1: ...LE7 40GU INSTRUCTION MANUAL Communication ...
Page 2: ......
Page 10: ...8 TRADEMARKS 150 ...
Page 11: ...9 CONTENTS ...
Page 37: ...3 CC LINK IE FIELD NETWORK BASIC COMMUNICATION 3 3 Reference Program 35 3 ...
Page 38: ...36 3 CC LINK IE FIELD NETWORK BASIC COMMUNICATION 3 3 Reference Program ...
Page 39: ...3 CC LINK IE FIELD NETWORK BASIC COMMUNICATION 3 3 Reference Program 37 3 ...
Page 40: ...38 3 CC LINK IE FIELD NETWORK BASIC COMMUNICATION 3 3 Reference Program ...
Page 57: ...4 SLMP COMMUNICATION 4 3 Reference Program 55 4 Program example ...
Page 58: ...56 4 SLMP COMMUNICATION 4 3 Reference Program ...
Page 59: ...4 SLMP COMMUNICATION 4 3 Reference Program 57 4 ...
Page 60: ...58 4 SLMP COMMUNICATION 4 3 Reference Program ...
Page 61: ...4 SLMP COMMUNICATION 4 3 Reference Program 59 4 ...
Page 82: ...80 5 MODBUS TCP SLAVE 5 3 Reference Program Program example ...
Page 83: ...5 MODBUS TCP SLAVE 5 3 Reference Program 81 5 ...
Page 84: ...82 5 MODBUS TCP SLAVE 5 3 Reference Program ...
Page 85: ...5 MODBUS TCP SLAVE 5 3 Reference Program 83 5 ...
Page 86: ...84 5 MODBUS TCP SLAVE 5 3 Reference Program ...
Page 110: ...108 6 N N NETWORK 6 4 Reference Program Program example ...
Page 111: ...6 N N NETWORK 6 4 Reference Program 109 6 ...
Page 112: ...110 6 N N NETWORK 6 4 Reference Program ...
Page 147: ...7 MODBUS RTU ASCII SLAVE 7 4 Reference Program 145 7 Function code H03 Read holding register ...
Page 149: ...7 MODBUS RTU ASCII SLAVE 7 4 Reference Program 147 7 ...
Page 153: ......