6
−
1
2
Do not install when the product (power cable) is
electrifi ed.
Doing so may result in electric shocks.
Use single
-
phase 220
-
240V power.
Using the incorrect power supply may cause fi res,
electric shocks or malfunctions.
Power cable
230
207
164
57.5
Appr
ox. 500mm
267
68
635
Conduit box
Recommended
installation heights
For men: 925mm
For women: 905mm
Power cable hole (rear face)
Terminal block
Appliance external shape
79.5 103.5
Unit (mm)
10
15.5
R3.5
R3.5
7
7
Detailed view of
installation holes
230
207
164
57.5
Mounting screws
(Included)
Installation
panel
635
Recommended
installation heights
For men: 925mm
For women: 905mm
Appliance shape
79.5 103.5
Appliance mounting
screw position
Unit (mm)
Installation method
Check
□
Single
-
phase 220
-
240V power is being used.
□
Make sure that a ground
-
fault circuit interrupter is installed in the fixed wiring.
□
A single wire (cable core: between 2.0mm
2
and 3.0mm
2
) is being used for the power cable.
Make sure that a means for
disconnection is incorporated in the fixed
wiring in accordance with the wiring rules.
Fix the installation panel to the wall using
the 4 mounting screws.
The position illustrated on the right is
recommended.
Use commercially available screw anchors when
installing the appliance on a concrete wall.
Reinforce any walls made with materials other
than concrete before installation.
Leave a space of at least 130mm below
the appliance.
Dirt or water sucked into the appliance
may damage it.
Follow the illustration on the right for the internal
wiring.
50
6.5
15
Appliance mounting screw
position
Cautions
15
6.5
50
Caution
Warning