—24—
12. Service inspection list
Location
Electric wiring
Operation
Inspection Item
Check Result
Are lead wire connectors connected securely?
Are all wires connected correctly?
Does it operate normally?
Isn’t there any abnormal noise, vibration, etc?
Is hot air blown?
Does every LED and illumination lamp turn on?
Heater
Indicator LED
Isn’t the product separated too far away from the wall?
(Normal clearance: About 2 mm)
Wall installation
11. How to call
Phenomenon
Cause, Inspection and Remedy
Wind is too weak to dry quickly.
1
Check if the filter is clogged.
2
Isn’t the wind volume knob set at the weak position?
Water leaks from the product.
1
Check if the drain tank is filled up. (Drain water.)
Since the main unit may absorb moisture if the product is
operate while the drain tank is full, drain water will flow over
when it is filled up beyond its capacity.
2
Is the drain tank installed properly?
Wind does not blow immediately after
turning on the power switch and
inserting hands.
It takes 1 second after turning on the power switch to charge the
control circuit. Operation is inhibited in the meantime.
Odor from the product
1
Check if the drain tank is filled up. (Drain water.)
2
Check the inside of drain tank for any foreign matters. (Remove
them.)
3
When operating the product initially, burning smell may arise as
oil or dust adhered to the heater burns. This is normal.
No hot wind is blown.
Is the heater switch turned ON?
Summary of Contents for JT-SB116EH-W-CA
Page 9: ... 9 JT SB116EH W CA 7 Electrical wiring diagram ...
Page 11: ... 12 2 Sub circuit JT 24S ...
Page 35: ...9 10 11 12 13 14 15 16 17 18 19 20 21 1 2 3 4 5 6 7 8 36 5 5 5 5 7 7 ...
Page 39: ...70 40 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 5 5 5 5 52 5 63 70 70 66 63 64 64 ...
Page 41: ...92 93 94 95 96 97 98 81 82 83 84 85 86 87 88 89 90 91 42 84 5 90 ...
Page 45: ... 46 131 132 133 134 135 ...