(4) Control of the heater temperature
1
Room thermostat detects the room temperature while the heater thermostat monitors the heater
temperature.
2
The room thermostat temperature determines the heater control temperature. (The colder the room
temperature, the heater control temperature becomes higher, and the hot air temperature is maintained at
about 35°C.)
3
Heater turns ON/OFF depending on the heater control temperature, but it does not turn ON in the following
occasions.
• When the heater switch is turned “OFF” (Heater lamp is extinguished.)
• When the jet towel is operating
• When the room thermostat detection temperature is 35°C or higher
(5) Extinguishing of the illumination lamp
1
If the jumper wire (JA) on the indicator circuit board (JT-24S-A) is cut off, the illumination lamp extinguishes.
2
Before cutting off the jumper wire, make sure to turn the power switch “OFF” and wait for 40 seconds
minimum.
(6) Test mode (Error display mode)
1
Content .….….….….Display the latest error occurred.
When no error is retained in the memory, the power lamp flickers quickly.
There is no other indication than the above. (Operation is inhibited.)
2
Setting method ….…In the condition that a resistor of 4.7k
Ω
is connected between pins 1 and 2 of CN8 on
the main circuit board, turn “ON” the power switch.
3
Resetting method …Turn “OFF” the power switch. After waiting for more than 40 seconds, remove the
above resistor.
Summary of Contents for JT-SB116EH-W-CA
Page 9: ... 9 JT SB116EH W CA 7 Electrical wiring diagram ...
Page 11: ... 12 2 Sub circuit JT 24S ...
Page 35: ...9 10 11 12 13 14 15 16 17 18 19 20 21 1 2 3 4 5 6 7 8 36 5 5 5 5 7 7 ...
Page 39: ...70 40 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 5 5 5 5 52 5 63 70 70 66 63 64 64 ...
Page 41: ...92 93 94 95 96 97 98 81 82 83 84 85 86 87 88 89 90 91 42 84 5 90 ...
Page 45: ... 46 131 132 133 134 135 ...