5
Unscrew the screw to remove the intake air duct.
(One PTT screw 4 x 14, indicated by
)
Intake air duct
Assembly precaution
Set the intake air duct in the groove of the blower cover. (Indicated
by
)
Blower assembly
8
Remove the blower stopper.
9
Remove the blower assembly.
Assembly precautions
• Set the blower assembly horizontally.
• When installing the blower stopper, make sure that it is not loose.
Blower stopper
When reassembling
Reassemble the unit in the reverse order of disassembly.
After reassembly, always make a test run to make sure that the unit
operates properly.
6
Unscrew the blower cover clamping screws.
(Four PTT screws 4 x 14, indicated by
)
Blower cover
Tightening torque:
1.0 ± 0.1 N.m
Tightening torque:
1.0 ± 0.1 N.m
7
Remove the cord bush from the lead wires.
→
See the picture of (6)