This manual confers no industrial property rights or any rights of any other 

kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation 

cannot be held responsible for any problems involving industrial property rights 

which may occur as a result of using the contents noted in this manual.

Warranty

Exclusion of loss in opportunity and secondary loss from warranty liability

Regardless of the gratis warranty term, Mitsubishi shall not be liable for 

compensation to:

(1) Damages caused by any cause found not to be the responsibility of     

Mitsubishi.

(2) Loss in opportunity, lost profits incurred to the user by Failures of Mitsubishi 

products.

(3) Special damages and secondary damages whether foreseeable or not, 

compensation for accidents, and compensation for damages to products 

other than Mitsubishi products.

(4) Replacement by the user, maintenance of on-site equipment, start-up test run 

and other tasks.

For safe use

This product has been manufactured as a general-purpose part for general 
industries, and has not been designed or manufactured to be incorporated in 
a device or system used in purposes related to human life.
Before using the product for special purposes such as nuclear power, electric 
power, aerospace, medicine or passenger movement vehicles, consult with 
Mitsubishi Electric.
This product has been manufactured under strict quality control. However 
when installing the product where major accidents or losses could occur if the 
product fails, install appropriate backup or failsafe functions in the system.

HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN

Side

A

Side

B

JAPANESE

ENGLISH

JY997D40401H

Side

B

Safety Precaution

 

(Read these precautions before using.)

Before using this product, please read this manual and the relevant manuals
introduced in this manual carefully and pay full attention to safety to handle the
product correctly.
The precautions given in this manual are concerned with this product.

In this manual, the safety precautions are ranked as 

 and 

.

Depending on circumstances, procedures indicated by 

 may also be

linked to serious results. 
In any case, it is important to follow the directions for usage.       

Indicates that incorrect handling may cause hazardous
conditions, resulting in death or severe injury.

Indicates that incorrect handling may cause hazardous
conditions, resulting in medium or slight personal injury or
physical damage.

DESIGN PRECAUTIONS

Some failures of the GOT or cable may keep the outputs on or off.

An external monitoring circuit should be provided to check for output signals

which may lead to a serious accident.

Not doing so can cause an accident due to false output or malfunction.

If a communication fault (including cable disconnection) occurs during

monitoring on the GOT, communication between the GOT and PLC CPU is

suspended and the GOT becomes inoperative.

A system where the GOT is used should be configured to perform any

significant operation to the system by using the switches of a device other

than the GOT on the assumption that a GOT communication fault will occur.

Not doing so can cause an accident due to false output or malfunction.

Do not use the GOT as the warning device that may cause a serious

accident. An independent and redundant hardware or mechanical interlock is

required to configure the device that displays and outputs serious warning.

Failure to observe this instruction may result in an accident due to incorrect

output or malfunction.

DESIGN PRECAUTIONS

Do not bundle the control and communication cables with main-circuit, power

or other wiring. Run the above cables separately from such wiring and keep

them a minimum of 100mm (3.94in.) apart.Not doing so noise can cause a

malfunction.

MOUNTING PRECAUTIONS

Make sure to turn off the Connector Conversion Box's power before attaching or

detaching it to/from the GOT.

Failure to do so may cause unit failure or malfunctions.

MOUNTING PRECAUTIONS

Use the Connector Conversion Box within the generic environment specifications

described in this manual. If the product is used in such conditions, electric shock,

fire, malfunctions, deterioration or damage may occur.

WIRING PRECAUTIONS

Be sure to shut off all phases of the external power supply used by the system

before wiring. Failure to do so may result in an electric shock, product damage or

malfunctions.

Please make sure to ground FG terminal of the Connector Conversion Box power

supply section by applying 100 or less which is used exclusively for the GOT. Not

doing so may cause an electric shock or malfunction.

Correctly wire the Connector Conversion Box power supply section after

confirming the rated voltage and terminal arrangement of the GOT. Not doing so

can cause a fire or failure.

Exercise care to avoid foreign matter such as chips and wire offcuts entering the

GOT. Not doing so can cause a fire, failure or malfunction.

WIRING PRECAUTIONS

Plug the communication cable into the connector of the connected unit and

tighten the mounting and terminal screws in the specified torque range.

Undertightening can cause a short circuit or malfunction. Overtightening can

cause a short circuit or malfunction due to the damage of the screws or unit.

TEST OPERATION 
PRECAUTIONS

Before performing the test operations of the user creation monitor screen (such as

turning ON or OFF bit device, changing the word device current value, changing

the settings or current values of the timer or counter, and changing the buffer

memory current value), read through the manual carefully and make yourself

familiar with the operation method. During test operation, never change the data

of the devices which are used to perform significant operation for the system.

False output or malfunction can cause an accident.

STARTUP/MAINTENANCE 
PRECAUTIONS

When power is on, do not touch the terminals.

Doing so can cause an electric shock or malfunction.

Before starting cleaning or terminal screw retightening, always switch off the

power externally in all phases. Not switching the power off in all phases can cause

a unit failure or malfunction. Undertightening can cause a short circuit or

malfunction. Overtightening can cause a short circuit or malfunction due to the

damage of the screws or unit.

STARTUP/MAINTENANCE 
PRECAUTIONS

Do not disassemble or modify the unit.

Doing so can cause a failure, malfunction, injury or fire.

Do not touch the conductive and electronic parts of the unit directly.

Doing so can cause a unit malfunction or failure.

The cables connected to the unit must be run in ducts or clamped.

Not doing so can cause the unit or cable to be damaged due to the dangling,

motion or accidental pulling of the cables or can cause a malfunction due to a

cable connection fault.

When unplugging the cable connected to the unit, do not hold and pull the cable

portion. Doing so can cause the unit or cable to be damaged or can cause a

malfunction due to a cable connection fault.

DISPOSAL PRECAUTIONS

When disposing of the product, handle it as industrial waste.

TRANSPORTATION 
PRECAUTIONS

The Connector Conversion Box is a precision instrument. During transportation,

avoid impacts larger than those specified in this manual. Failure to do so may

cause failures in the unit. After transportation, verify the operations of the unit.

Certification of UL, cUL standards

UL, cUL Standards are recognized in use by the following combination.

GT2506HS-VTBD

GT2505HS-VTBD

GT1665HS-VTBD (Hardware version F or later)

GT1455HS-QTBDE (Hardware version B or later)

GT1450HS-QMBDE (Hardware version B or later)

GT16H-CNB-42S (Hardware version D or later)

External cable (GT16H-C30-42P, GT16H-C60-42P, GT16H-C100-42P)

External cable (GT14H-C30-42P, GT14H-C60-42P, GT14H-C100-42P)

*1

*1 Version B or later

General notes on power supply

This equipment must be supplied by a UL Listed or Recognized 24 V dc rated

power supply and UL Listed or Recognized fuse rated not higher than 4A, or a UL

Listed Class 2 power supply.

Compliance with EC directive (CE Marking)

This note does not guarantee that an entire mechanical module produced in

accordance with the contents of this note will comply with the following standards.

Compliance to EMC directive for the entire mechanical module should be checked by

the user/manufacturer. For more details please contact the local Mitsubishi Electric

sales site.

Attention

This product is designed for use in industrial applications.

Requirement for Compliance with EMC directive

The following products have shown compliance through direct testing (to the

identified standards) and design analysis (forming a technical construction file) to the

European Directive for Electromagnetic Compatibility (2004/108/EC) when used as

directed by the appropriate documentation.

Type: Programmable Controller (Open Type Equipment)

For more details please contact the local Mitsubishi Electric sales site.

Notes for compliance to EMC regulation

1) General notes on the control panel

Make sure to combine the GT16 Handy GOT with the Connector Conversion

Box to comply with the EMC directive. The Connector Conversion Box is an

open type device (device installed to another device) and must be installed in a

conductive control panel.

2) General notes on the use of communication cables

External cable (GT16H-C30-42P, GT16H-C60-42P, GT16H-C100-42P)

Direct connection cable

Ethernet connection cable (Shielded twisted pair cable (STP)) 

PLC (manufactured by other company), microcomputer, temperature

controller, inverter, servo amplifier, CNC, MODBUS(R)/RTU or MODBUS(R)/

TCP connection

Produce the cable (RS-232 cable, RS-422 / 485 cable) for connecting the GOT

to a controller with reference to the following manual.

 GOT2000/GOT1000 Series Connection Manual for GT Works3 and a

controller used

3) General notes on Power supply

The Connector Conversion Box requires an
additional ferrite filter to be attached to the
24V DC power supply cables. The filter
should be attached in a similar

 

manner as

shown in the figure opposite, i.e. the power
c ab l es   a re   w ra p pe d   ar ou n d  t h e  f i l te r.
However, as with all EMC situations the more
correctly applied precautions the better the
systems Electro-magnetic Compatibility. The
ferrite recommended is a TDK ZCAT3035-
1330 or similar. The ferrite should be placed
as near to the 24V DC terminals of the
Connector Conversion Box as possible (which
should be within 75mm of the GOT terminal).

Associated Manuals

The following manuals are relevant to this product. When these loose manuals are
required, please consult with our local distributor.

For details of a PLC to be connected, refer to the PLC user's manual respectively.

Referenced Standard: GB/T15969.2 (Requirement of Chinese standardized law)

Bundled Items

 

1. Features

The Connector Conversion Box relays the GOT's external 42-pin connector to the
power supply/switch and the PLC's connector and terminal block, while enabling
users to operate the Handy GOT outside the enclosure.

2. Specifications

General Specifications 
Other specifications are the same as the Handy GOT main unit.

Standard

Remark

EN61131-2 : 2007
P r o g r a m m a b l e
controllers- Equipment,
requirement and tests

EMI

Compliance with all relevant aspects of the
standard. (Radiated Emissions)

EMS

Compliance with all relevant aspects of the
standard. (ESD, RF electromagnetic field, EFTB,
Surge, RF conducted disturbances and Power
frequency magnetic field)

Existing Cables

User Made Cables

GT01-C30R4-8P
GT11H-C30R2-6P

The cable need to be independently tested by the user to
demonstrate EMC compatibility when they are used with
the GOT, the PLC of MELSEC-Q series, MELSEC-L series,
MELSEC-QnA, MELSEC-A series and MELSEC-FX series.

Up to 75mm

(2.95inch)

TDK

Manual name

Contents

Manual Number

(Model Code)

GOT2000 Series 
User's Manual 
(Hardware)

Describes the GOT hardware relevant
content such as part names, external
dimensions, mounting, power supply
wiring, specifications, and introduction
to option devices

SH-081194ENG

(1D7MJ5)

GOT2000 Series 
Handy GOT 
Connection Manual 
For GT Works3 
Version1

Describes system configurations of the
connection method applicable to
GOT2000 Series Handy GOT and
cable creation method

SH-081867ENG

(1D7MS9)

GT16 Handy GOT 
User's Manual 
(Hardware/Utility, 
Connection) 1/2, 2/2 
(sold separately)

Describes the Handy GOT hardware-
relevant content such as part names,
external dimensions, mounting, power
supply wiring, specifications, and
introduction to option devices

JY997D41201
JY997D41202

(09R821)

GT14 Handy GOT 
User's Manual 
(Hardware/Utility, 
Connection) 1/2, 2/2 
(sold separately)

Describes the Handy GOT hardware-
relevant content such as part names,
external dimensions, mounting, power
supply wiring, specifications, and
introduction to option devices

JY997D50201
JY997D50202

(09R825)

Bundled item

Quantity

GT16H-CNB-42S Connector conversion box

1

Packing for panel installation

1

Flange for GT10-9PT5S

1

Screws for flange installation (M3×8)

2

CONNECTOR CONVERSION BOX GT16H-CNB-42S User’s

Manual (This manual)

1

Item

Specifications

Operating 
ambient 
temperature

0 to 55

C

Storage 
ambient 
temperature

-20 to 70

C

Vibration 
resistance

When
installing
DIN rail

Frequency Acceleration

Half-

amplitude

Sweep 

Count

5 to 9Hz

--

1.75mm

10 times 

each in X, Y 

and Z 

directions

9 to 150Hz

4.9m/s

2

--

Operating 
atmosphere

Must be free of lamp black, corrosive gas, flammable gas, or
excessive amount of electroconductive dust particles and must be no
direct sunlight. (Same as for saving)

Control panel or
operation panel

PLC

GT16H-CNB-42S

Connector Conversion Box

Handy GOT

External cable

GT16H-C□□□-42P
GT14H-C□□□-42P

(Option)

Power Supply Specifications

Applicable GOTs

Internal Relay Contact Specifications

*1 The system may not match the safety standards. Before using the system, please check the safety standards which are required.

3. Part Names and External Dimensions

The name and the external dimensions of each part of the Connector Conversion
Box are described below.

Item

Specifications

Input power supply voltage

24VDC (+10% -15%)

Power consumption

13.7W or less (570mA/24VDC) (When including the consumption current of Handy GOT)

Connector Conversion Box only

2.2W (90mA/24V) (When excluding the consumption current of Handy GOT)

Inrush current

25A or less (at max. load), 2ms

Permissible instantaneous power failure time

Within 5ms

Abbreviations

Model name

GOT 2000

GT25 Handy GOT

GT2506HS-VTBD, GT2505HS-VTBD

GOT 1000

GT16 Handy GOT

GT1655HS-VTBD

GT14 Handy GOT

GT145

HS-Q

BDE

Item

Contact rating

Specifications

Operation switch
SW1 to SW6

10mA/24VDC
(resistance load only)

Each contact coordinates the operation switch status of Pressed (close)/Not pressed (open).
When the external cable is not connected, contacts are always open regardless of the switch status.

Emergency stop
switch
ES1A to ES3A

1A/24VDC
(resistance load)
0.3A/24VDC
(induction load)

Each contact coordinates the emergency stop switch status of Pushed (open)/Return (close). When the external cable is not
connected, contacts are always open regardless of the emergency stop switch status. Causing a short circuit of the ES

B

terminal which is close to the ES

A terminal by a short pin (prepared by user) enables to set each contact in the close status

even if the external connection cable is not connected.

*1

GOT2000 Series User's Manual(Hardware), GT16 Handy GOT User’s Manual, GT14 Handy GOT User’s Manual

When using the short-circuited ES

B terminal which is close to the ES

A terminal

Contacts are normally operated in the close status. When pushing the emergency stop switch, the contacts become open.

In the following situations, contacts are closed regardless of the status of the emergency stop switch and the external cable.

- When GT16H-CNB-42S is turned OFF.
- When GT16H-CNB-42S is not supplied with the power supply (DC24V).

Grip switch
DSW1, DSW2

1A/24VDC
(resistance load)
0.3A/24VDC
(induction load)

Each contact coordinates the grip switch status of Pressed (close)/Not pressed (open).
When the external cable is not connected, contacts are always open regardless of the grip switch status.

Keylock switch
(2-position switch)
KSWC, KSW1, 
KSW2

1A/24VDC
(resistance load)
0.3A/24VDC
(induction load)

Each contact coordinates the position of the keylock switch.

When the key is on the left: KSW1 and KSWC are short-circuited.

When the key is on the right: KSW2 and KSWC are short-circuited.

When the external cable is not connected, contacts are always open regardless of the keylock switch.

No.

Name

Specifications

1)

Connector for Handy GOT 
(42-pin, female)

Connects a Handy GOT through an external 
connection cable.

2)

Power switch

Supplies the power to the Handy GOT.
When this switch is set to ON, the power is 
supplied. Turn off the power when attaching 
or detaching the Handy GOT.

3)

POWER LED

Lit in green: Power is correctly supplied. Not
lit: Power is not supplied.

4)

Hole for the panel installation

Used when mounting the panel. For M4
screw, depth 6mm

5)

Packing attachment chase

Used when mounting the panel.

about 130 (5.12")*

1)

12)

6) 7)

16)

9)

15)

8)

14)

13)

5)

2)

3)

4)

11)

126 (4.97")

110 (4.34")

Unit: mm (inch)

Weight: about 0.5kg

10)

55 (2.17")

56 (2.21")

about

65 (2.56")*

External cable 

connected

Terminal block

cover opened

*Space required for connecting the cable

6)

Hook for DIN rail

Used for fixing the Connector Conversion
Box when mounting DIN rail (35mm).

7)

Hole for the screw installation

Used for fixing on the board, etc. For M4
screw

8)

Terminal block 1

Connects the GT16H-CNB-42S, the 24VDC
power supply of H andy GOT and the
emergency stop switch (ES-1 to 3) with M3
terminal screw and the cover.

9)

Terminal block 2

Connects the operation switch of the Handy
GOT (SW1 to 6), the grip switch (DSW-1, 2)
and the keylock switch (KSW-1, 2) with M3
terminal and the cover.

10)

External connection device
communication connector
(RS-232: D-Sub, 9-pin, male)

Connects to the external connection device
via a GOT2000/GOT1000 series cable.
R S - 4 2 2 / 4 8 5   c o n n e c t o r   a n d   R S - 2 3 2
connector cannot be used at the same time.
These connectors cannot be used in
combination with GT2505HS-VTBD and
GT145

HS-Q

BDE.

11)

External connection device
communication connector
(RS-422/485: D-Sub, 9-pin,
female)

12)

External connection device
communication connector
(Ethernet: RJ-45 module jack)

Connects the external connection device via
Ethernet with using a LAN cable.

13) Rotary switch (U)

Sets the ID number of GT16-CNB-42S.
Sets one ID number with using both rotary
switches (U) and (L).

14) Rotary switch (L)

15)

I D   n u m b e r   v a l i d / i n v a l i d
selection switch

Enables the recognition function of ID
number (ON=Valid, OFF=Invalid).
When connecting the external connection
device with using 10) and 11), set OFF
(invalid).

16) Hole for the flange installation

Used for fixing the flange when using the
connector conversion adapter.

No.

Name

Specifications

4. Installation

The Connector Conversion Box can be installed on the panel face directly or on the DIN rail.

4.1 Mounting on the panel face 

(When setting the connector for Handy GOT connection and the power supply switch on the panel surface)

1) Direct mounting on the panel face

Drill a mounting slot of the following size on the panel face.

2) Installation of the packing

Install the accessory packing to the packing attachment chase of the
Connector Conversion Box. Be sure to install the packing.

3) Mounting on the panel face

Fit the Connector Conversion Box from the back side of the panel face, and fix it with four M4 screws (prepared by user).
In the Connector Conversion Box, thread of M4, 6mm (0.23”) in depth is cut in each mounting hole. Prepare four M4 mounting screws separately while considering the
thickness of the panel face. (Tightening torque: 0.69 to 0.88 N•m)
Make sure that interfering objects are not located within 65mm (2.56”) from the rear face so that the connector of a PLC cable is not hindered.
To wire the terminal block, keep a space of 25mm (0.98”) or more on both sides of the Connector Conversion Box.

4.2 Mounting on the panel face (When installing the Connector Conversion Box on the panel surface)

1) Mounting on the panel face

Install the Connector Conversion Box on the panel face (mounting surface). Drill screw holes on the panel face as follows. Tighten the mounting screw with the specified
torque. Tightening screws too much may cause damage. (Tightening torque: 0.69 to 0.88 N•m)

4.3 Installed on the DIN rail

Install the Connector Conversion Box on the DIN rail
with using its DIN rail hook.
(Applicable DIN rail DIN46277 (width: 35mm (1.37”))
The clearance between screws for install the DIN
rail should be 150mm (5.9”) or less.

4-R3 max (Panel opening)

85±0.5 (3.35"±0.02")

77±0.5 (3.04"±0.02")

Drill 4-   5±0.5 (0.2"±0.02")

87+1,-0 (3.43"+0.04",-0)

(Panel opening)

61+1,-0 (2.41"+0.04",-0) 

(Panel opening)

Panel cut area

Unit: mm (inch)

Packing attachment chase

Elevation view

25 (0.99")

25 (0.99")

65 (2.56")

Unit: mm (inch)

118 (4.65")

4 (0.16")

43 (1.7") 6 (0.24")

4-   4.5 (0.18")

M4 screw and nut

× 4 sets

(prepared by user)

Unit: mm (inch)

DIN rail depth

more than 10mm (0.4"inch)

1) Pull out the hook for

    DIN rail.

2) Adapt the upper side of 

    the DIN rail installation 

    slot to the DIN rail.

3) Lock the hook for DIN rail 

    while forcing the product on 

    the DIN rail.

    When installing the DIN rail, 

    please fix the cables. 

   Otherwise, the hook for DIN

    rail and other parts may be

   damaged by the cable load.

CONNECTOR CONVERSION BOX

GT16H-CNB-42S

User's Manual

This manual describes the part names, dimensions, mounting, and specifications
of the product. Before use, read this manual and manuals of relevant products
fully to acquire proficiency in handling and operating the product. Make sure to
learn all the product information, safety information, and precautions.
And, store this manual in a safe place so that you can take it out and read it
whenever necessary. Always forward it to the end user.
Registration
Ethernet is a registered trademark of Xerox Corporation in the United States.
MODBUS is a trademark of Schneider Electric SA. The company name and the
product name to be described in this manual are the registered trademarks or
trademarks of each company.

Effective April 2018
Specifications are subject to change without notice.

 2010 MITSUBISHI ELECTRIC CORPORATION

Manual Number

JY997D40401H

Date

April 2018