7 Communication Using MC Protocol
80
FX
3U
-ENET-ADP User's Manual
7.5 Device Memory Read/Write
7.5.7
Test in word units (random write) (command: 05)
The examples shown in this section explain the command/response format when writing data by designating
word device memories or bit device memories (16 point units) arbitrarily. These examples are not applicable
for writing the current values of C200 to C255 (32-bit devices).
For more details on the order and content of data items of the areas marked by " * " shown in the control
procedure diagram, refer to Subsection 7.3.2.
[Control procedure]
Specifying Y20 to Y37 to on/off, R26 to "1234H," and the current value of C18 to "50H" at the PLC on which
the Ethernet adapter is loaded.
1) Communication in binary code
Current value of CN18
50
H
1234
H
Y30
Y37
Y20
Y27
0 0 1 0 1 0 0 1 0 1 1 1 1 0 1 1
Y20
R26
1....ON
0....OFF
05
H
FF
H
0A
H
03
H
00
H
80
H
00
H
00
H
00
H
20
H
59
H
29
H
7B
H
1A
H
00
H
00
H
00
H
20
H
52
H
34
H
12
H
12
H
00
H
00
H
00
H
4E
H
43
H
50
H
00
H
00
H
85
H
00
H
L
L
-
H L
H
-
-
-
H L
-
H L
-
-
-
H L
-
H L
-
-
-
H
(Data name)
External device
side
(Example)
(Data name)
PLC side
(Example)
Subheader
PC No.
N
um
be
r of
d
ev
ice
po
in
ts
Monitoring
timer
Designated device
Subheader
Complete code
to
to
Designated device
Designated device
De
vic
e da
ta
(O
N/
O
FF
d
esig
na
tion
)
Device data
Device data
*
*