![Mitsubishi Electric FR-F720-0.75K to 110K Instruction Manual Download Page 322](http://html.mh-extra.com/html/mitsubishi-electric/fr-f720-0-75k-to-110k/fr-f720-0-75k-to-110k_instruction-manual_239806322.webp)
313
For customers who are replacing the conventional model with this inverter
(4) Main differences and compatibilities with the FR-F500(L) series
Appendix 1-2 Replacement of the FR-A100 <EXCELENT> series
Instructions for installation
• When using the installation holes of the FR-A100(E) series, FR-A5AT (intercompatibility attachment) is necessary.
Item
FR-F500(L)
FR-F700
Changed/cleared
functions
Simple mode parameters 61
Simple mode parameters 15
Pr. 0 Torque boost
initial value
11K to 55K: 2%
Pr. 0 Torque boost
initial value
initial value
11K to 37K: 2%, 45K, 55K: 1.5%
(When the torque boost value of the FR-F500 series used
was the initial value, it is not necessary to change the
torque boost value from the initial value when replacing
with the FR-F700 series.)
User group 1 (16), user group 2 (16)
(
Pr. 160, Pr. 173
to
Pr. 175
)
User group (16) only
Setting methods were partially changed
(
Pr. 160, Pr. 172
to
Pr. 173
)
User initial value setting (
Pr. 199
)
"User initial value setting" (
Pr. 199
) was cleared
Substitutable with the copy function of the operation panel
(FR-DU07)
DC injection brake function with terminal (X13
signal)
(Pr. 11 setting value 8888, Pr. 180 to Pr. 186 setting
value 13)
DC injection brake function with terminal was cleared
Start in reverse rotation is possible with flying start function
(frequency search of automatic restart after instantaneous
power failure function)
Long wiring mode
(Pr. 240 setting 10, 11)
Setting is not necessary
(Pr. 240 settings "10" and "11" were cleared)
Intelligent optimum acceleration/deceleration
(
Pr. 60
setting "3" and
Pr. 61
to
Pr. 63
)
Function was cleared
For deceleration time, overvoltage fault can be avoided
with regeneration avoidance function (
Pr. 882
to
Pr. 885
).
Automatic torque boost
(
Pr. 38
,
Pr. 39
)
Automatic torque boost was cleared because of addition of
"Simple magnetic flux vector" (
Pr. 80
)
Performing parameter clear and all clear (H5A96,
HAA99) with the FR-A7ND clears
Pr. 345
and
Pr. 346
.
Pr. 345
and
Pr. 346
are not cleared.
Terminal block Removable terminal block
Removable terminal block
Upward compatibility (Terminal block of the F500 can be
mounted)
PU
FR-PU04, DU04
FR-PU07
FR-DU07
FR-DU04 unavailable (Partly restricted when the FR-PU04
is used.
Refer to page 312.
)
Plug-in option
Dedicated plug-in option (not compatible)
Computer link, relay output option
FR-A5NR
Built into the inverter
(RS-485 terminal, relay output 2 points)
Three boards can be mounted
One board can be mounted
Installation size
FR-F720-0.75K, 2.2K, 3.7K, 7.5K, 18.5K, 22K, 37K, 45K,
FR-F740-0.75K to 3.7K, 7.5K, 22K, 37K to 55K are compatible in mounting dimensions
For other capacities, an optional intercompatibility attachment (FR-AAT) is necessary.