19
62
Reference value at
acceleration
0 to 200%, 9999
9999
63
Reference value at
deceleration
0 to 200%, 9999
9999
65
Retry selection
0 to 5
0
66
Stall prevention operation
reduction starting frequency
0 to 400Hz
60Hz
67
Number of retries at fault
occurrence
0 to 10, 101 to
110
0
68
Retry waiting time
0.1 to 360s
1s
69
Retry count display erase
0
0
70
Special regenerative brake
duty
0 to 30%
0%
71
Applied motor
0, 1, 3 to 6, 13 to
16, 23, 24, 40,
43, 44, 50, 53,
54
0
72
PWM frequency selection
0 to 15
1
73
Analog input selection
0, 1, 10, 11
1
74
Input filter time constant
0 to 8
1
75
Reset selection/disconnected
PU detection/PU stop
selection
0 to 3, 14 to 17
14
77
Parameter write selection
0, 1, 2
0
78
Reverse rotation prevention
selection
0, 1, 2
0
79 Operation mode selection
0, 1, 2, 3, 4, 6, 7
0
80
Motor capacity
0.1 to 15kW,
9999
9999
81
Number of motor poles
2, 4, 6, 8, 10,
9999
9999
82
Motor excitation current
0 to 500A, 9999
9999
83
Rated motor voltage
0 to 1000V
200V/
400V
84
Rated motor frequency
10 to 120Hz
60Hz
89
Speed control gain (Advanced
magnetic flux vector)
0 to 200%, 9999
9999
90
Motor constant (R1)
0 to 50
Ω
, 9999
9999
91
Motor constant (R2)
0 to 50
Ω
, 9999
9999
92
Motor constant (L1)
0 to 1000mH,
9999
9999
93
Motor constant (L2)
0 to 1000mH,
9999
9999
94
Motor constant (X)
0 to 100%, 9999
9999
96
Auto tuning setting/status
0, 1, 11, 21
0
117
PU communication station
number
0 to 31 (0 to 247)
0
118
PU communication speed
48, 96, 192, 384
192
119
PU communication stop bit
length
0, 1, 10, 11
1
120
PU communication parity
check
0, 1, 2
2
121
Number of PU communication
retries
0 to 10, 9999
1
122
PU communication check time
interval
0, 0.1 to 999.8s,
9999
0
123
PU communication waiting
time setting
0 to 150ms,
9999
9999
124
PU communication CR/LF
selection
0, 1, 2
1
125
Terminal 2 frequency setting
gain frequency
0 to 400Hz
60Hz
Pr.
Name
Setting Range
Initial
Value
126
Terminal 4 frequency setting
gain frequency
0 to 400Hz
60Hz
127
PID control automatic
switchover frequency
0 to 400Hz, 9999
9999
128 PID action selection
0, 20, 21, 40 to
43, 50, 51, 60,
61
0
129 PID proportional band
0.1 to 1000%,
9999
100%
130 PID integral time
0.1 to 3600s,
9999
1s
131 PID upper limit
0 to 100%, 9999
9999
132 PID lower limit
0 to 100%, 9999
9999
133 PID action set point
0 to 100%, 9999
9999
134 PID differential time
0.01 to 10.00s,
9999
9999
145 PU display language selection 0 to 7
1
146 Parameter for manufacturer setting. Do not set.
147
Acceleration/deceleration time
switching frequency
0 to 400Hz, 9999
9999
150 Output current detection level 0 to 200%
150%
151
Output current detection signal
delay time
0 to 10s
0s
152 Zero current detection level
0 to 200%
5%
153 Zero current detection time
0 to 1s
0.5s
156
Stall prevention operation
selection
0 to 31, 100, 101
0
157 OL signal output timer
0 to 25s, 9999
0s
158 AM terminal function selection
1 to 3, 5, 7 to 12,
14, 21, 24, 52,
53, 61, 62
1
160 User group read selection
0, 1, 9999
0
161
Frequency setting/key lock
operation selection
0, 1, 10, 11
0
162
Automatic restart after
instantaneous power failure
selection
0, 1, 10, 11
1
165
Stall prevention operation level
for restart
0 to 200%
150%
168
Parameter for manufacturer setting. Do not set.
169
170 Watt-hour meter clear
0, 10, 9999
9999
171 Operation hour meter clear
0, 9999
9999
172
User group registered display/
batch clear
9999, (0 to 16)
0
173 User group registration
0 to 999, 9999
9999
174 User group clear
0 to 999, 9999
9999
178 STF terminal function selection
0 to 5, 7, 8, 10,
12, 14 to 16, 18,
24, 25, 60, 62,
65 to 67, 9999
60
179
STR terminal function
selection
0 to 5, 7, 8, 10,
12, 14 to 16, 18,
24, 25, 61, 62,
65 to 67, 9999
61
Pr.
Name
Setting Range
Initial
Value