17
190
RUN terminal function
selection
0, 1, 3, 4, 7, 8,
11 to 16, 25, 26,
46, 47, 64, 70,
80, 81, 90, 91,
93
, 95, 96, 98,
99, 100, 101,
103, 104, 107,
108, 111 to 116,
125, 126, 146,
147, 164, 170,
180, 181, 190,
191, 193
,
195, 196, 198,
199, 9999
0
192
A,B,C terminal function
selection
99
197
SO terminal function selection
80
232
Multi-speed setting (speed 8)
0 to 400Hz,
9999
9999
233
Multi-speed setting (speed 9)
0 to 400Hz,
9999
9999
234
Multi-speed setting (speed
10)
0 to 400Hz,
9999
9999
235
Multi-speed setting (speed 11)
0 to 400Hz,
9999
9999
236
Multi-speed setting (speed
12)
0 to 400Hz,
9999
9999
237
Multi-speed setting (speed
13)
0 to 400Hz,
9999
9999
238
Multi-speed setting (speed
14)
0 to 400Hz,
9999
9999
239
Multi-speed setting (speed
15)
0 to 400Hz,
9999
9999
240
Soft-PWM operation selection 0, 1
1
241
Analog input display unit
switchover
0, 1
0
244
Cooling fan operation
selection
0, 1
1
245
Rated slip
0 to 50%, 9999
9999
246
Slip compensation time
constant
0.01 to 10s
0.5s
247
Constant-power range slip
compensation selection
0, 9999
9999
249
Earth (ground) fault detection
at start
0, 1
0
250
Stop selection
0 to 100s, 1000
to 1100s, 8888,
9999
9999
251
Output phase loss protection
selection
0, 1
1
255
Life alarm status display
(0 to 15)
0
256
Inrush current limit circuit life
display
(0 to 100%)
100%
257
Control circuit capacitor life
display
(0 to 100%)
100%
258
Main circuit capacitor life
display
(0 to 100%)
100%
259
Main circuit capacitor life
measuring
0, 1 (2, 3, 8, 9)
0
260
PWM frequency automatic
switchover
0, 1
0
261
Power failure stop selection
0, 1, 2
0
267
Terminal 4 input selection
0, 1, 2
0
Pr.
Name
Setting Range
Initial
Value
268
Monitor decimal digits
selection
0, 1, 9999
9999
269
Parameter for manufacturer setting. Do not set.
295
Magnitude of frequency
change setting
0, 0.01, 0.10,
1.00, 10.00
0
296
Password lock level
1 to 6,
101 to 106,
9999
9999
297
Password lock/unlock
1000 to 9998
(0 to 5, 9999)
9999
298
Frequency search gain
0 to 32767,
9999
9999
299
Rotation direction detection
selection at restarting
0, 1, 9999
0
338
Communication operation
command source
0, 1
0
339
Communication frequency
command source
0, 1, 2
0
340
Communication startup mode
selection
0, 1, 10
0
342
Communication EEPROM
write selection
0, 1
0
343
Communication error count
—
0
450
Second applied motor
0, 1, 9999
9999
495
Remote output selection
0, 1, 10, 11
0
496
Remote output data 1
0 to 4095
0
502
Stop mode selection at
communication error
0, 1, 2
0
503
Maintenance timer
0 (1 to 9998)
0
504
Maintenance timer alarm
output set time
0 to 9998, 9999
9999
549
Protocol selection
0, 1
0
551
PU mode operation command
source selection
2, 4, 9999
9999
555
Current average time
0.1 to 1s
1s
556
Data output mask time
0 to 20s
0s
557
Current average value
monitor signal output
reference current
0 to 500A
Rated
inverter
current
561
PTC thermistor protection
level
0.5 to 30k
Ω
,
9999
9999
563
Energization time carrying-
over times
(0 to 65535)
0
564
Operating time carrying-over
times
(0 to 65535)
0
571
Holding time at a start
0 to 10s, 9999
9999
575
Output interruption detection
time
0 to 3600s, 9999
1s
576
Output interruption detection
level
0 to 400Hz
0Hz
577
Output interruption cancel
level
900 to 1100%
1000%
611
Acceleration time at a restart 0 to 3600s, 9999
9999
653
Speed smoothing control
0 to 200%
0
665
Regeneration avoidance
frequency gain
0 to 200%
100
872
Input phase loss protection
selection
0, 1
0
882
Regeneration avoidance
operation selection
0, 1, 2
0
Pr.
Name
Setting Range
Initial
Value