(M) Monitor display and monitor output signal
105
5
GROUP
M
5.4.2
Output terminal function selection
Output signal list
• The functions of the output terminals can be set.
• Refer to the following table and set the parameters. (0 to 99: Positive logic, 100 to 199: Negative logic)
Use the following parameters to change the functions of the open collector output terminals and relay output terminals.
Pr.
Name
Initial
value
Initial signal
Setting range
190
M400
RDB terminal
function selection
Open
collector
output
terminal
111
RDB (Inverter operation
enable (NC contact))
2, 8, 11, 17, 25, 26, 64 to 66, 68, 90,
94, 95, 98, 99, 102, 108, 111, 125,
126, 164 to 166, 168, 190, 194, 195,
198, 199, 206, 207, 209, 210, 214,
227, 306, 307, 309, 310, 327, 9999
191
M401
RDA terminal
function selection
11
RDA (Inverter operation
enable (NO contact))
192
M402
IPF terminal function
selection
2
IPF (Instantaneous power
failure/undervoltage)
193
M403
RSO terminal
function selection
209
RSO (Inverter reset)
194
M404
FAN terminal
function selection
25
FAN (Fan fault output)
195
M405
ABC1 terminal
function selection
Relay output
terminal
99
ALM (Fault)
Setting
Signal
name
Function
Operation
Related
parameter
Refer
to
page
Positive
logic
Negative
logic
2
102
IPF
Instantaneous
power failure/
undervoltage
Output when an instantaneous power failure or
undervoltage protection operation occurs.
Pr.57
8
108
THP
Electronic thermal
O/L relay pre-alarm
Output when the cumulative electronic thermal O/L
relay value reaches 85% of the trip level. (Electronic
thermal O/L relay protection (E.THC) is activated
when the value reaches 100%.)
—
11
—
RDA
Inverter operation
enable (NO
contact)
Output when the converter unit operation is ready.
—
—
111
RDB
Inverter operation
enable (NC
contact)
Output when a converter unit fault occurs or the
converter is reset. (inverse to the logic of RDA)
17
—
Y17
Control signal for
main circuit power
supply MC
Output while the self power management function is
enabled. Turns OFF when a fault activating the self
power management operation occurs.
Pr.248, Pr.30
25
125
FAN
Fan fault output
Output when a fan fault occurs.
—
26
126
FIN
Heat sink overheat
pre-alarm
Output when the heat sink temperature reaches about
85% of the heat sink overheat protection operation
temperature.
—
64
164
Y64
During retry
Output during retry operation.
Pr.67, Pr.514,
Pr.515, Pr.523
65
165
Y65
Emergency drive in
operation
Output during emergency drive operation.
66
166
ALM3
Fault output during
emergency drive
Output when a fault occurs during emergency drive
operation.
68
168
EV
24 V external
power supply
operation
Output while operating with a 24 V power supply input
from an external source.
—
90
190
Y90
Life alarm
Output when any of the control circuit capacitor, the
inrush current limit circuit, or the cooling fan
approaches the end of its life.
Pr.255 to Pr.257
94
194
ALM2
Fault output 2
Output when the converter unit's protective function is
activated to stop the output (at fault occurrence).
The signal output continues even during a converter
reset, and the signal output stops after the reset
release.
—
95
195
Y95
Maintenance timer
signal
Output when
Pr.503
reaches the
Pr.504
setting or
higher.
Pr.503, Pr.504