PPO TYPE SUPPORT SPECIFICATION
65
7
7.7 Standard parameters
You can use the PNU to make parameter settings from the network.
The table below lists PNU numbers corresponding to parameter numbers.
Standard parameter examples are introduced below. Refer to the examples and make parameter settings.
The usable parameters depend on the inverter. Refer to the Instruction Manual (Detailed) of the inverter
for details of the
parameters.
Representation of the PNU for standard parameters (Example:
Pr.902
)
• Example of parameter list
NOTE
• Write to
Pr.77
and
Pr.79
is not allowed from the network with FR-A8NP. (Read is allowed.)
• To read or write parameter of
Pr.1000
or later, set Bit 0 of the ext-index number (extended parameter access) = "1".
PNU
Name
Data
type
Bit 0 of the ext-index number = "0"
Bit 0 of the ext-index number = "1"
P1000
Pr.0 Torque boost
Pr.1000
Us16
P1001
Pr.1 Maximum frequency
Pr.1001
Us16
P1002
Pr.2 Minimum frequency
Pr.1002 Lq tuning target current adjustment coefficient
Us16
P1003
Pr.3 Base frequency
Pr.1003 Notch filter frequency
Us16
P1004
Pr.4 Multi-speed setting (high speed)
Pr.1004 Notch filter depth
Us16
P1005
Pr.5 Multi-speed setting (middle speed)
Pr.1005 Notch filter width
Us16
P1006
Pr.6 Multi-speed setting (low speed)
Pr.1006 Clock (year)
Us16
··
·
··
·
··
·
··
·
P1902.1
Sub-Index Number
1000+Parameter Number