8

PRE-OPERATION INSTRUCTIONS

1.2 Component names

Symbol

Name

Description

Refer to 

page

a

Mounting hole

Fixes the option to the inverter with screws, or installs spacers.

10

b

Terminal block

Connects the device to input the signal to the inverter, and the device to 
receive the signal from the inverter.

13

c

Switch for manufacturer setting

Switch for manufacturer setting. Do not change the initial setting (

).

d

Connector

Connects to the option connector of the inverter.

10

Front view

Rear view

(a)

(a)

(b)

(d)

(c)

(a)

(a)

AM0

AM1

SE

Y0

Y1

Y2

Y3

AMC

SE

Y4

Y5

Y6

Summary of Contents for FR-A8AY E KIT

Page 1: ...INSTRUCTION MANUAL INVERTER Plug in option PRE OPERATION INSTRUCTIONS 1 INSTALLATION 2 PARAMETER LIST 3 ANALOG OUTPUT 4 DIGITAL OUTPUT 5 FR A8AY Analog output function Digital output function ...

Page 2: ...harging part of the circuitry and get an electric shock Do not remove the inverter front cover even if the power supply is disconnected The only exception for this would be when performing wiring and periodic inspection You may accidentally touch the charged inverter circuits and get an electric shock Before wiring or inspection LED indication of the inverter unit operation panel must be switched ...

Page 3: ...ckaging Sterilization of disinfection of wooden package should also be performed before packaging the product Trial run Before starting operation each parameter must be confirmed and adjusted A failure to do so may cause some machines to make unexpected motions Warning Usage Do not modify the equipment Do not perform parts removal which is not instructed in this manual Doing so may lead to fault o...

Page 4: ...ing 13 3 PARAMETER LIST 17 4 ANALOG OUTPUT 19 4 1 Connection diagram 19 4 2 Terminals 20 4 3 Extended analog output function parameter list 21 4 4 Adjustment procedure 22 4 4 1 Analog output signal voltage current switchover Pr 309 setting 22 4 4 2 Meter calibration 24 4 4 3 Setting output signals 26 4 4 4 Analog meter voltage negative output selection Pr 1019 26 4 4 5 Adjusting the analog signal ...

Page 5: ...l output function parameter list 31 5 3 Parameter setting 31 Notes on descriptions in this Instruction Manual Connection diagrams in this Instruction Manual appear with the control logic of the input terminals as sink logic unless otherwise specified ...

Page 6: ...lug in option out of the package check the product name and confirm that the product is as you ordered and intact This product is a plug in option for the FR A800 F800 series 1 1 1 Product confirmation Check the enclosed items Plug in option 1 Mounting screw M3 8 mm 2 Refer to page 10 Spacer 2 Refer to page 10 ...

Page 7: ...0 b Terminal block Connects the device to input the signal to the inverter and the device to receive the signal from the inverter 13 c Switch for manufacturer setting Switch for manufacturer setting Do not change the initial setting d Connector Connects to the option connector of the inverter 10 Front view Rear view a a b d c a a AM0 AM1 SE Y0 Y1 Y2 Y3 AMC SE Y4 Y5 Y6 ...

Page 8: ...4 VDC 0 1 A Item Voltage output Current output Output signal 0 to 10 VDC max across terminals AM0 to AMC 0 to 20 mADC across terminals AM1 to AMC Output resolution 3 mV 10 A Applicable meter DC voltmeter Full scale 10 V internal impedance 10 k or more DC ammeter Full scale 20 mA internal impedance 300 or less Wiring length maximum 10 m ...

Page 9: ...nual Detailed of the inverter for details on how to remove the front cover 2 For the two mounting holes as shown in the next page that will not be tightened with mounting screws insert spacers 3 Fit the connector of the plug in option to the guide of the connector on the inverter unit side and insert the plug in option as far as it goes 4 Fit the two locations the left and right of the plug in opt...

Page 10: ...INSTALLATION 11 2 Spacer Spacer Spacer Mounting screw Mounting screw Mounting screw Spacer Spacer Spacer Mounting screw Connector 1 Connector 2 Connector 3 Insertion positions for screws and spacers ...

Page 11: ...ors 1 2 and 3 on the inverter in this order and options having a lower priority do not function When the inverter cannot recognize that the option unit is mounted due to improper installation etc the protective function E 1 to E 3 is activated A different indication will appear according to the mounted position option connector 1 to 3 When removing the plug in option remove the two screws on the l...

Page 12: ... off Wire the stripped cable after twisting it to prevent it from becoming loose In addition do not solder it Crimp the blade terminal Insert wires to a blade terminal and check that the wires come out for about 0 to 0 5 mm Check the condition of the blade terminal after crimping Do not use a blade terminal of which the crimping is inappropriate or the face is damaged Cable sheath stripping length...

Page 13: ... Crimping tool name With insulation sleeve Without insulation sleeve For UL wire 0 3 AI 0 5 10WH Phoenix Contact Co Ltd CRIMPFOX 6 0 5 AI 0 5 10WH AI 0 5 10WH GB 0 75 AI 0 75 10GY A 0 75 10 AI 0 75 10GY GB 1 AI 1 10RD A 1 10 AI 1 10RD 1000GB 1 25 1 5 AI 1 5 10BK A 1 5 10 0 75 for two cables AI TWIN 2 0 75 10GY Cable gauge mm2 Blade terminal product number Insulation product number Manufacturer Cri...

Page 14: ...mly with a flathead screwdriver 2 Insert the cable into a socket When using a single wire or stranded wires without a blade terminal push the open close button all the way down with a flathead screwdriver and insert the wire Flathead screwdriver Open close button Flathead screwdriver Open close button ...

Page 15: ...ip is used terminal block may be damaged Commercially available product as of February 2012 The product may be changed without notice Place the flathead screwdriver vertical to the open close button In case the blade tip slips it may cause an inverter damage or injury When wiring cables to the inverter s RS 485 terminals while a plug in option is mounted take caution not to let the cables touch th...

Page 16: ...100 0 1 100 309 M342 Analog output signal voltage current switchover 0 1 10 11 1 0 310 M343 Analog meter voltage output selection 1 2 311 M344 Setting for zero analog meter voltage output 0 to 100 0 1 0 312 M345 Setting for maximum analog meter voltage output 0 to 100 0 1 100 323 M346 AM0 0V adjustment 900 to 1100 1 1000 324 M347 AM1 0mA adjustment 900 to 1100 1 1000 418 M432 Extension output term...

Page 17: ... Pr 190 to Pr 196 output terminal function selection in the Instruction Manual Detailed of the inverter Digital output 313 M410 DO0 output selection 1 9999 30 and later 314 M411 DO1 output selection 315 M412 DO2 output selection 316 M413 DO3 output selection 317 M414 DO4 output selection 318 M415 DO5 output selection 319 M416 DO6 output selection Pr Pr group Name Setting range Minimum setting incr...

Page 18: ...quency and output current can be output from the voltage output terminal AM0 and current output terminal AM1 Connect the voltmeter or ammeter as shown below NOTE The wiring length for the voltmeter ammeter should be within 10 m Power supply Voltmeter Ammeter FR A8AY 0 to 10 VDC 0 to 20 mADC AM0 AM1 AMC Inverter Motor MCCB M ...

Page 19: ...l Do not use Terminal symbol Terminal name Description AM0 Voltage output terminal Connects the DC voltmeter 10 VDC AM1 Current output terminal Connects the DC ammeter 20 mADC AMC Common terminal Common terminal for AM0 and AM1 Y0 to Y6 Used for digital output function Refer to page 30 SE ...

Page 20: ... signal selection 1 2 307 Setting for zero analog output 0 to 100 0 1 0 308 Setting for maximum analog output 0 to 100 0 1 100 309 Analog output signal voltage current switchover 0 1 10 11 1 0 310 Analog meter voltage output selection 1 2 311 Setting for zero analog meter voltage output 0 to 100 0 1 0 312 Setting for maximum analog meter voltage output 0 to 100 0 1 100 323 AM0 0V adjustment 900 to...

Page 21: ...tion Terminal 0 Initial value Outputs the same selection signal from both the voltage output terminal AM0 and the current output terminal AM1 The signal that set in Pr 306 Analog output signal selection is enabled The Pr 310 setting is disabled AM0 Pr 306 Pr 307 Pr 308 Selects the output signal Output signal value when analog output is zero Output signal value when analog output is at maximum Pr 3...

Page 22: ...l value when analog output is at maximum Pr 323 C0 Pr 900 AM1 Pr 306 Pr 307 Pr 308 Selects the output signal Output signal value when analog output is zero Output signal value when analog output is at maximum Pr 324 C1 Pr 901 11 AM0 Pr 310 Pr 311 Pr 312 Selects the output signal Analog output value when output signal is zero Analog output value when output signal is at maximum Pr 323 C0 Pr 900 AM1...

Page 23: ...this time the following analog signal is actually output and deflects the meter across terminals AM0 AMC Maximum output voltage set previously factory setting 10 VDC across terminals AM1 AMC Maximum output current set previously factory setting 20 mADC If the meter needle does not point to 0 when voltage or current input is 0 use Pr 323 AM0 0 V adjustment or Pr 324 AM1 0 mA adjustment to calibrate...

Page 24: ...ut voltage set previously factory setting 10 VDC Maximum output current set previously factory setting 20 mADC Connect a DC voltmeter or DC ammeter across terminals AM0 or terminal AM1 and AMC Set 21 reference voltage output in Pr 306 and Pr 310 After making adjustment with to deflect the meter to full scale press to set If the meter needle does not point to 0 when voltage or current input is 0 us...

Page 25: ...al AM0 analog voltage output can be displayed with minus signs on the monitor For the monitored items that can have minus signs refer to the description of Pr 54 FM CA terminal function selection and Pr 158 AM terminal function selection in the Instruction Manual Detailed of the inverter NOTE When terminal AM0 analog voltage output is output with a minus sign the output will be within the 10V DC t...

Page 26: ...og output and Pr 308 for terminal AM1 and Pr 312 for terminal AM0 at maximum analog output Refer to page 22 NOTE When Pr 307 Pr 308 and Pr 311 Pr 312 the output values from the terminals AM0 and AM1 will always be zero Pr 309 0 1 Pr 1019 0 output without minus sign Pr 1019 1 output with minus sign 0 Output signal value 100 100 Output signal value Pr 308 or Pr 312 for maximum analog output Output s...

Page 27: ...gnal value Output signal value Pr 307 or Pr 311 for zero analog output Analog output value Pr 308 or Pr 312 for maximum output signal Current AM1 20 mA Voltage AM0 10 V Analog output Limited at 10 V Limited at 10 V 100 100 0 Output signal value Output signal value Pr 307 or Pr 311 for zero output signal Analog output value Pr 308 or Pr 312 for maximum output signal Current AM1 20 mA Voltage AM0 10...

Page 28: ...m the terminals AM0 and AM1 accordingly then connect the meter When calibrating the meter using Pr 323 Pr 324 C0 Pr 900 and C1 Pr 901 while Pr 309 10 or 11 set 0 in Pr 307 or Pr 311 and 100 in Pr 308 or Pr 312 to prevent calibration value deviation All the outputs are shut off when a protective function E 1 to E 3 is activated Caution This product is initially set to provide the full scale output ...

Page 29: ...n using Pr 313 Y1 Assigns the function using Pr 314 Y2 Assigns the function using Pr 315 Y3 Assigns the function using Pr 316 Y4 Assigns the function using Pr 317 Y5 Assigns the function using Pr 318 Y6 Assigns the function using Pr 319 SE Common terminal Common terminals for the terminals Y0 to Y6 Isolated from the terminal SE of the inverter AM0 Used for analog output function Refer to page 19 A...

Page 30: ... to Pr 319 are the same as those of Pr 190 to Pr 196 output terminal function selection For the details of Pr 190 to Pr 196 refer to the Instruction Manual Detailed of the inverter NOTE The same function can be set to two output terminals or more Parameter number Name Initial value Setting range 313 DO0 output selection 9999 314 DO1 output selection 9999 315 DO2 output selection 9999 316 DO3 outpu...

Page 31: ...of 5 to 50 ms Operation example for the RUN signal NOTE The response level is not adjusted while Pr 418 9999 When Pr 157 OL signal output timer is set for the Overload warning OL signal output the OL signal is output when the set time of Pr 157 Pr 418 elapses Time RUN Pr 418 9999 ON OFF RUN Pr 418 9999 ON OFF Pr 418 Pr 418 Output frequency ...

Page 32: ...33 MEMO ...

Page 33: ...The manual number is given on the bottom left of the back cover Print date Manual number Revision Aug 2013 IB NA 0600497ENG A First edition Oct 2014 IB NA 0600497ENG B Addition Compatibility with the FR F800 series ...

Page 34: ...INVERTER HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN IB NA 0600497ENG B 1410 MEE Printed in Japan Specifications subject to change without notice ...